Combined synopsis and solicitation, total small business set-aside
BLDG 854 Repair MV Switch x2
W50S85-24-Q-A015
Department of the Army, W7NF Uspfo Activity Miang 127. Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance.
Awarded
$24,898.00 obligated so far on USAspending
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one was awarded in 2024
42 like it are open now in commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance
- J039 - Equipment Maintenance - Golden Gate National Cemetery
Department of Veterans Affairs, National Cemetery Admin
Sources soughtNAICS 811310San Bruno, CA36C78627Q0027Closes in 2 daysNov 3 - AH-64 Non-Rotating Control Swashplate Assembly Liner Replacement
Department of the Army, W6QK Ccad Contr Off
Combined synopsis and solicitationNAICS 811310Corpus Christi, TXAP63B4-6246-6056Closes in 2 daysNov 3 - FIRE DAMPER REPAIR SERVICES VA Central California Healthcare System
Department of Veterans Affairs, 261-Network Contract Office 21
Sources soughtNAICS 811310Fresno, CA36C26127Q0138Closes in 3 daysNov 4
Description
As published on SAM.gov.
Building 854 on Selfridge ANGB has (2) two Vacuum Circuit Breakers that need to be refurbished. This service is to troubleshoot, repair and refurbish two backup MV Vacuum Circuit Breakers. Vacuum Circuit Breaker # (1) one has problems closing. Vacuum Circuit Breaker # (2) two has a burned-out motor. Contractor shall adhere to standards in accordance with OSHA and NFPA 70E. Provide all necessary equipment, personnel, and materials for testing.
Contractor shall work with 127 Civil Engineer office for electrical requirements while removing and installing breakers. At SANGB, contractor shall remove medium voltage vacuum breakers from building 854 and transport them to contractor’s location. Troubleshoot, repair breakers, and provide new parts to restore breaker to functionality. All repairs are in accordance with approved manufacturer recommendations and industry standards and parts.
Test breakers at contractor’s location; when ready the contractor shall return breakers to SANGB, install and test breakers in building 854. Prior to acceptance, the Government POC shall observe testing. Provide a signed test report that certifies completion.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- California Breakers, Inc.
- UEI
- CJA6DLU7KDV1
- CAGE
- 356Z7
- Vendor location
- Vista, CA
- Contract
- W50S8524PA011, purchase order
- Obligated
- $24,898.00
- Actions
- 1 between April 30, 2024 and April 30, 2024
- Competition
- Competed Under SAP, 8 offers received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- Repair Two (2) MV Vacuum Circuit Breakers
- Match
- solicitation number W50S8524QA015 equals the FPDS solicitation identifier; same awarding office W50S85 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 2, 2024
Combined synopsis and solicitation
Due April 17, 2024 at 2:00 PM EDT. SAM.gov, notice b1a3ee0a2aab4cb189a37c206c15cef1
April 2, 2024
Combined synopsis and solicitation
Due April 17, 2024 at 2:00 PM EDT. SAM.gov, notice f99b3bc90e7c472a95c6d7bfaea28b2b
April 9, 2024
Combined synopsis and solicitation
Due April 17, 2024 at 2:00 PM EDT. SAM.gov, notice 2154f7e121974bc698be892a4c882f57
Points of contact
- Austin Parksaustin.parks.8@us.af.mil5862395235