Special notice, first published as sources sought
Enhanced Vyleater Vial Disposal System Model II-Xe
PANHCA-26-029301
Department of the Army, W40M MRC0 West. Surgical and Medical Instrument Manufacturing.
Response deadline
May 29, 2026 at 1:00 PM EDT
Closed 156 days ago. Posted June 2, 2026, first published May 15, 2026. Scheduled to archive June 24, 2026.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2026
17 like it are open now in surgical and medical instrument manufacturing
- Sterilizer
Department of Veterans Affairs, 257-Network Contract Office 17
Sources soughtNAICS 339112Anywhere in the US36C25727Q0054Closes in 2 daysNov 3 - Medical Equipment Brand Name Replacement Parts
Department of the Army, W40M USA Hca
Sources soughtNAICS 339112Anywhere in the USPANHCA-27-P-0000034278Closes in 4 daysNov 5 - Anesthesia Units Amendment 4
Department of Veterans Affairs, 241-Network Contract Office 01
PresolicitationNAICS 339112Anywhere in the US36C24125R0116Closes tomorrowNov 2
All 17 open in surgical and medical instrument manufacturing
Description
As published on SAM.gov.
Enhanced Vyleater Vial Disposal System Model II-Xe. DPALS process about 3,000 cytology thin prep vials per month that need to be disposed of in a safe and efficient manner. The device must be able to accommodate vials in their whole form. The device must be explosion resistant to substances with a flash point of 27 °C / 81 °F. The devise should separate solid waste materials in a separate container from the liquid waste. The device should be self-contained. The disposal system must comply with hazard waste guidelines. The device should not alter the waste material. The device should come with training for all technicians that will be required to utilize it. The device should be able to withstand mild exposure to environmental elements. The device needs to accommodate approximately 300 vials being disposed of per day, with each vial holding approximately 20ml of methanol-based solution. The regional technical support and service from manufacturer should be available in case the parts need to be ordered to repair. The operators training support should be available as requested. The device should be simple and easy to use for non-experienced operators. The device should be durable and easy to clean.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Notice of Intent to Sole Source PANHCA-26-P-029301.pdf131 KB, June 2, 2026
- Sources Sought Notice.pdf156 KB, May 15, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
May 15, 2026
Sources sought
Due May 29, 2026 at 1:00 PM EDT. SAM.gov, notice b20a956802d44719a648bc8af3b56c0e
1 revisions on SAM
- May 15, 2026: publish, sources sought
June 2, 2026
Special notice
Due June 9, 2026 at 1:30 PM EDT. SAM.gov, notice 66cbb83323bb4982a8528834925f1d26
1 revisions on SAM
- June 2, 2026: publish, special notice
Points of contact
- Derrick J Johnsonderrick.j.johnson2.civ@health.mil2102214811