Skip to content
  • 6,813 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell Abierto what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and Abierto tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans
AbiertoGet started

Special notice, total small business set-aside

CRG PACE Heater Sources Sought

F3A1AM01

Department of the Air Force, Department of the Air Force. Plumbing, Heating, and Air-Conditioning Contractors.

Response deadline

June 15, 2026 at 3:00 PM EDT

Closed 139 days ago. Posted June 5, 2026. Scheduled to archive June 30, 2026.

Get the next one like this from Department of the Air Force by email, the day it is posted.Find my opportunities

This one closed in 2026

1 like it is open now in plumbing, heating, and air-conditioning contractors

Description

As published on SAM.gov.

1. General:

The CRG requires rapid deployment capabilities across the globe with equipment suitable for sustainment of operations. Current assets do not meet arctic and sub-arctic requirements for reliant heating for personnel and equipment in the field. UTS is the sole provider for a heating solution feasible for a light and lean approach. Through procurement of 14 UTS HH75 Heaters, it will satisfy the gap we face for locations reaching below -10°F and reinforce our global prowess.  

2.  Objectives:

The 621 CRG needs a capability that enables its force elements to operate in any AOR, including arctic and sub-arctic conditions while remaining light, lean, and agile; the UTS HH75 Heater is essential to this capability since it outperforms the current heating capability of the Environmental Control Unit (ECU). The UTS 5-ton Environmental Control Unit (ECU) meets most theater requirements for operating limitations. The main limitation is ambient operating temperatures of -25 to 125°F. To meet arctic and sub-arctic conditions the need for the UTS HH75 Heater is paramount. The Heater is multi-fueled (DF1, DF2, JP5, JP8, Kerosene). Ambient operating temperature is based off the fuel utilized. Kerosene used as fuel for the Heater opens the door to temperatures as low as -50°F. In colder environments, the ECU will push at most, 12Kw (40,000 BTU/hr) of heat. The 12Kw also translates to load on the generator which increases fuel consumption dramatically. Dependent on set-up, the generator would utilize about 4 gal an hour due to the ECUs maxing out. The UTS HH75 Heater would pull only 3Amps for the electronic controls and mainly rely on its 11.6gal fuel tank. Under continuous use, it would pull .53 gal per hour. A full tank would sustain heating needs for 22 hours.

3.  Scope of Work:

This equipment will be used for the 621st Contingency Response Wing 621 CRW operations, on base and various locations for deployments, training, and exercises. The vendor will provide and deliver the equipment with standard manufacturer warranty to meet global availability for contingency forces to include arctic and sub-arctic regions. The 621 CRW will be responsible for maintaining the accountability and maintenance of the equipment past the warranty period.

4.  Personnel:

The vendor will provide delivery of this item. The maintenance, accountability, and operations of this equipment will be the responsibility of the CRG AGE/Electrical Power Production Work Center.

5.  Equipment Requirements and peripheral shall meet or exceed the specs of:

Heat Output: 75,000 BTU/H

Dimensions: 44.0” L x 16.4” W x 25.0” H

Tank Capacity: 11.6 Gallons

Fuel Consumption under Continuous Use: 0.53 gallons per hour

Fuel Requirements: DF1, DF2, JP5, JP8, and Kerosene

Power Requirements: 120 VAC, 60 Hz, Single Phase

Power Usage: 3 Amps @120V

Accessories Included: Exhaust Stack, Heater Ducts (2), Remote Thermostat, O&M Manual

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. June 5, 2026

    Special notice

    Due June 15, 2026 at 3:00 PM EDT. SAM.gov, notice 27bbecd51b70482389598d00a92f9f89

    1 revisions on SAM
    • June 5, 2026: publish, special notice

Points of contact