VAMC Hampton is looking for a Water Purification system with the following:

- Salient Characteristics - Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities - MODEL MEDICA-R 200 - Make-up rate 15C 200 l/hr - Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1) - Organics (TOC) - typical <30ppb -500 PPB (1) Bacteria - typical <10 CFU/ml (2) - Particles 0.2 m filter Silica <0.05 mg/l - Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures - Feedwater Requirement: - Source: Tap water as detailed below Conductivity: <1000 S/cm - Contaminant: - Measure:

Range:

Pretreatment: - Calcium: Ca ppm as CaCO3 <250 None3 - >250 Softener or use very low RO recovery3 - Free chlorine: Cl2ppm <0.1 None - 0.1 0.5 20 inch carbon block - >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm - Chloramine: Cl2 ppm <0.1 None - 0.1 0.5 20 inch high efficiency carbon (5) - >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm - Silica: SiO2 ppm <30 None - >30 20 inch cartridge depth filter or use very low RO recovery (4) - Fouling index: FI <10 None - 10 to 20 20 inch cartridge depth filter - >20 Back washable media filter with a minimum flow rate of 20 l/min - Iron/manganese: Fe/Mn ppm <0.05 None - >0.05 20 inch cartridge depth filter (5) - >0.1 Back-washable Fe filter (6) - Organics: TOC ppm C <2 None - 2 to 3 20 inch carbon block (4) - >3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C) -- Flowrate: (requirement at 15°C) 20 l/min - Drain requirements: (gravity fall with air gap) 45 l/min - Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum - Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, - 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required) - Must include Installation, Commissioning, Training - Electrical Requirements Mains Input: 115V, 60Hz - System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA - Electrical protection rating 20 amps Noise level during recirculation <70dBA -

Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters. - -The floor drain must be a minimum of 3" and meet all applicable building codes and system requirements - -Actual Unit measurement 32" Wide x35"Deep x72"High

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
HA3GWLK3JK58
CAGE
72XB4
Vendor location
Pittsburgh, PA
Contract
36C24626P0550, purchase order
Obligated
$0.00
Actions
2 between March 31, 2026 and April 9, 2026
Competition
Competed Under SAP, 1 offer received
Set-aside reported
No Set Aside Used.
Described as
Dialysis Water System
Match
solicitation number 36C24626Q0335 equals the FPDS solicitation identifier; same awarding office 36C246 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. February 9, 2026

    Sources sought

    Due February 17, 2026 at 10:00 AM EST. SAM.gov, notice fd16752ac47f4f01b09800caf95aec3c

  2. March 18, 2026

    Sources sought

    Due March 24, 2026 at 10:00 AM EDT. SAM.gov, notice 60d5c179b2a4412e93c8a6f486e7a963

Points of contact