{"canonical":"https://abierto.us/opportunities/36c24626q0335","key":"36C24626Q0335","url":"https://abierto.us/opportunities/36c24626q0335","title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","solicitation_number":"36C24626Q0335","notice_type":"r","open":false,"response_deadline":"2026-03-24T14:00:00Z","first_posted":"2026-02-09","last_posted":"2026-03-18","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"333310","psc":"4610","set_aside":null,"place_state":null,"winner":"EVOQUA WATER TECHNOLOGIES LLC","award_amount":null,"publications":[{"notice_id":"fd16752ac47f4f01b09800caf95aec3c","title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","solicitation_number":"36C24626Q0335","notice_type":"r","base_type":"r","posted":"2026-02-09","posted_at":null,"due_at":"2026-02-17T15:00:00Z","due_date":"2026-02-17","cancelled":null,"archived":null,"archive_date":"2026-03-19","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fd16752ac47f4f01b09800caf95aec3c/view","enriched":false,"history":[]},{"notice_id":"60d5c179b2a4412e93c8a6f486e7a963","title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","solicitation_number":"36C24626Q0335","notice_type":"r","base_type":"r","posted":"2026-03-18","posted_at":null,"due_at":"2026-03-24T14:00:00Z","due_date":"2026-03-24","cancelled":null,"archived":null,"archive_date":"2026-04-24","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/60d5c179b2a4412e93c8a6f486e7a963/view","enriched":false,"history":[]}],"latest_notice_id":"60d5c179b2a4412e93c8a6f486e7a963","first_type":"r","notices":[{"dates":{"posted":"2026-02-09","response_deadline":{"raw":"2026-02-17T10:00:00-05:00","utc":"2026-02-17T15:00:00Z","date":"2026-02-17","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fd16752ac47f4f01b09800caf95aec3c/view"},"naics":{"codes":["333310"],"primary":"333310"},"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-03-19","archive_type":"auto_custom"},"contacts":[{"name":"John P Harmsen","role":"primary","email":"john.harmsen@va.gov","phone":"757-722-7961","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"fd16752ac47f4f01b09800caf95aec3c","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"6871d8c18f5ce32d30c06123b5ee778ec6331fd43b951595bebd75226cbc0af4","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"VAMC Hampton is looking for a Water Purification system with the following: - Salient Characteristics - Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities - MODEL MEDICA-R 200 - Make-up rate 15C 200 l/hr - Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1) - Organics (TOC) - typical <30ppb -500 PPB (1) Bacteria - typical <10 CFU/ml (2) - Particles 0.2 m filter Silica <0.05 mg/l - Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures - Feedwater Requirement: - Source: Tap water as detailed below Conductivity: <1000 S/cm - Contaminant: - Measure: Range: Pretreatment: - Calcium: Ca ppm as CaCO3 <250 None3 - >250 Softener or use very low RO recovery3 - Free chlorine: Cl2ppm <0.1 None - 0.1 0.5 20 inch carbon block - >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm - Chloramine: Cl2 ppm <0.1 None - 0.1 0.5 20 inch high efficiency carbon (5) - >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm - Silica: SiO2 ppm <30 None - >30 20 inch cartridge depth filter or use very low RO recovery (4) - Fouling index: FI <10 None - 10 to 20 20 inch cartridge depth filter - >20 Back washable media filter with a minimum flow rate of 20 l/min - Iron/manganese: Fe/Mn ppm <0.05 None - >0.05 20 inch cartridge depth filter (5) - >0.1 Back-washable Fe filter (6) - Organics: TOC ppm C <2 None - 2 to 3 20 inch carbon block (4) - >3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C) -- Flowrate: (requirement at 15°C) 20 l/min - Drain requirements: (gravity fall with air gap) 45 l/min - Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum - Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, - 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required) - Must include Installation, Commissioning, Training - Electrical Requirements Mains Input: 115V, 60Hz - System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA - Electrical protection rating 20 amps Noise level during recirculation <70dBA - ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters. - -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements - -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24626Q0335","product_service_code":"4610"},{"dates":{"posted":"2026-03-18","response_deadline":{"raw":"2026-03-24T10:00:00-04:00","utc":"2026-03-24T14:00:00Z","date":"2026-03-24","time":"10:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/60d5c179b2a4412e93c8a6f486e7a963/view"},"naics":{"codes":["333310"],"primary":"333310"},"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-04-24","archive_type":"auto_custom"},"contacts":[{"name":"John P Harmsen","role":"primary","email":"john.harmsen@va.gov","phone":"757-722-7961","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"60d5c179b2a4412e93c8a6f486e7a963","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"5c79ae1fe4482c711c7b6da81b847e4d0f6516e65982bc43fa28aa6722eaf99d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"VAMC Hampton is looking for a Water Purification system with the following: - Salient Characteristics - Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities - MODEL MEDICA-R 200 - Make-up rate 15C 200 l/hr - Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1) - Organics (TOC) - typical <30ppb -500 PPB (1) Bacteria - typical <10 CFU/ml (2) - Particles 0.2 m filter Silica <0.05 mg/l - Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures - Feedwater Requirement: - Source: Tap water as detailed below Conductivity: <1000 S/cm - Contaminant: - Measure: Range: Pretreatment: - Calcium: Ca ppm as CaCO3 <250 None3 - >250 Softener or use very low RO recovery3 - Free chlorine: Cl2ppm <0.1 None - 0.1 0.5 20 inch carbon block - >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm - Chloramine: Cl2 ppm <0.1 None - 0.1 0.5 20 inch high efficiency carbon (5) - >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm - Silica: SiO2 ppm <30 None - >30 20 inch cartridge depth filter or use very low RO recovery (4) - Fouling index: FI <10 None - 10 to 20 20 inch cartridge depth filter - >20 Back washable media filter with a minimum flow rate of 20 l/min - Iron/manganese: Fe/Mn ppm <0.05 None - >0.05 20 inch cartridge depth filter (5) - >0.1 Back-washable Fe filter (6) - Organics: TOC ppm C <2 None - 2 to 3 20 inch carbon block (4) - >3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C) -- Flowrate: (requirement at 15°C) 20 l/min - Drain requirements: (gravity fall with air gap) 45 l/min - Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum - Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, - 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required) - Must include Installation, Commissioning, Training - Electrical Requirements Mains Input: 115V, 60Hz - System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA - Electrical protection rating 20 amps Noise level during recirculation <70dBA - ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters. - -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements - -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24626Q0335","product_service_code":"4610"}],"due_at":"2026-03-24T14:00:00Z","due_date":"2026-03-24","closes_at":"2026-03-24T14:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","state":null,"country":null,"winner_key":"HA3GWLK3JK58","amount":null,"linked_awards":2,"cancelled":false,"archived":false,"updated_at":"2026-09-16T17:40:17.704408Z","principal_notice_id":"60d5c179b2a4412e93c8a6f486e7a963","description":{"text":"VAMC Hampton is looking for a Water Purification system with the following: - Salient Characteristics - Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities - MODEL MEDICA-R 200 - Make-up rate 15C 200 l/hr - Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1) - Organics (TOC) - typical <30ppb -500 PPB (1) Bacteria - typical <10 CFU/ml (2) - Particles 0.2 m filter Silica <0.05 mg/l - Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures - Feedwater Requirement: - Source: Tap water as detailed below Conductivity: <1000 S/cm - Contaminant: - Measure: Range: Pretreatment: - Calcium: Ca ppm as CaCO3 <250 None3 - >250 Softener or use very low RO recovery3 - Free chlorine: Cl2ppm <0.1 None - 0.1 0.5 20 inch carbon block - >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm - Chloramine: Cl2 ppm <0.1 None - 0.1 0.5 20 inch high efficiency carbon (5) - >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm - Silica: SiO2 ppm <30 None - >30 20 inch cartridge depth filter or use very low RO recovery (4) - Fouling index: FI <10 None - 10 to 20 20 inch cartridge depth filter - >20 Back washable media filter with a minimum flow rate of 20 l/min - Iron/manganese: Fe/Mn ppm <0.05 None - >0.05 20 inch cartridge depth filter (5) - >0.1 Back-washable Fe filter (6) - Organics: TOC ppm C <2 None - 2 to 3 20 inch carbon block (4) - >3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C) -- Flowrate: (requirement at 15°C) 20 l/min - Drain requirements: (gravity fall with air gap) 45 l/min - Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum - Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, - 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required) - Must include Installation, Commissioning, Training - Electrical Requirements Mains Input: 115V, 60Hz - System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA - Electrical protection rating 20 amps Noise level during recirculation <70dBA - ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters. - -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements - -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","html":null,"origin":"extract"},"contacts":[{"name":"John P Harmsen","role":"primary","email":"john.harmsen@va.gov","phone":"757-722-7961","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"naics_codes":["333310"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_36C24626P0550_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24626P0550_3600_-NONE-_-NONE-/","piid":"36C24626P0550","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"HA3GWLK3JK58","recipient_name":"EVOQUA WATER TECHNOLOGIES LLC","recipient_uei":"HA3GWLK3JK58","recipient_cage":"72XB4","recipient_city":"PITTSBURGH","recipient_state":"PA","sub_name":"Department of Veterans Affairs","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","office_key":"o-36C246","first_action_date":"2026-03-31","last_action_date":"2026-04-09","actions":2,"obligated":"0","current_total_value":"0","potential_total_value":"0","naics":"333310","psc":"6515","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":1,"description":"DIALYSIS WATER SYSTEM","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24626Q0335 equals the FPDS solicitation identifier","same awarding office 36C246"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24626Q1036","latest_notice_id":"75bc4197ee664c2f8e7d5114088460f3","title":"Richmond VAMC Parking Attendant (Valet) Services","solicitation_number":"36C24626Q1036","notice_type":"o","first_type":"p","first_posted":"2026-09-04","last_posted":"2026-09-04","notices":2,"due_at":"2026-09-17T16:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T16:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"812930","psc":"M1LZ","set_aside":"SDVOSBC","state":"VA","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"AAB830EE967D4BA3A3305C0790979415","latest_notice_id":"1f8228006f8549f2a2f4b0764d490a2f","title":"DENTAL WATER LINE TESTING","solicitation_number":"_1","notice_type":"o","first_type":"o","first_posted":"2026-09-14","last_posted":"2026-09-14","notices":1,"due_at":"2026-09-17T16:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T16:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"541380","psc":"L046","set_aside":"SDVOSBC","state":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"36C24626Q08440001","latest_notice_id":"dfd38ba6389d4dbea93c7d391a5342b8","title":"Electric Truck","solicitation_number":"36C24626Q0844_0001","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-17T19:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T19:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"336110","psc":"2320","set_aside":"SBA","state":"NC","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"36C24626Q1078","latest_notice_id":"a85d59c8d28f488e86b27bb55e6fe515","title":"S218--Snow and Ice Service Removal Agreement","solicitation_number":"36C24626Q1078","notice_type":"r","first_type":"r","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":2,"due_at":"2026-09-18T13:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T13:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"561730","psc":"S218","set_aside":null,"state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:50:43.959643Z"},{"key":"36C24626Q09561","latest_notice_id":"c8e79643fa5c4e5f8e61b7bd47cfe8fd","title":"STERILE DRIER CABINET Package","solicitation_number":"36C24626Q0956_1","notice_type":"o","first_type":"o","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":1,"due_at":"2026-09-18T20:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T20:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"339113","psc":"6515","set_aside":"SDVOSBC","state":"NC","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:50:43.959643Z"}]}