X-ray Tube Cover Repair VA-26-00082614
36C24126Q0697
Department of Veterans Affairs, 241-Network Contract Office 01. Electronic and Precision Equipment Repair and Maintenance.
Response deadline
July 31, 2026 at 4:30 PM EDT
Closed 47 days ago. Posted July 29, 2026. Scheduled to archive August 30, 2026.
Description
As published on SAM.gov.
This notice is being published in accordance with the Federal Acquisition Regulation (FAR) Part 5, requiring the dissemination of information on proposed contract actions. This is a notice of intent to award a sole-source contract pursuant to 10 U.S.C 2304 (C)(1), as implemented by FAR 6, only one responsible source, and no other supplies or services will satisfy agency requirements, and brand-name descriptions.
The Department of Veterans Affairs Medical Center located at 1400 VFW Parkway, West Roxbury, MA 02132-4927 has a requirement for Siemens IR C-Arm (EE 226991) System Corrective Maintenance Service. The Government intends to award a firm-fixed-price sole source contract. A determination by the Government not to compete with this proposed contract based upon responses to this notice is solely within the discretion of the Government. This notice of intent is not a request for competitive proposals.
This is a written notice to inform the public of the Government's intent to award on a sole source basis. Interested parties may identify their interest and capability to respond to the requirement. Any response to this notice must show clear and convincing evidence that competition will be advantageous to the Government. Please contact Manasés Cabrera, Contracting Specialist, with the responses or questions regarding this requirement at manases.cabrera@va.gov. This notice will close on July 31, 2026, at 4:30 PM Eastern Standard Time (EST) STATEMENT FOR SCOPE OF WORK Siemens IR C-Arm (EE 226991)
Down System Corrective Maintenance Service REQUESTING SERVICE:
HTM VA Boston Healthcare System West Roxbury INTRODUCTION: The purpose of this service is to have one (1) Corrective maintenance service performed on the IR C-ARM (EE 226991), which is currently down. The vendor, Siemens Medical, is required to ensure that this medical device system meets all OEM safety and functional standards.
BACKGROUND: The IR C-arm is used by the radiology department located in IR West Roxbury. The system is basically used to diagnose and treat patients with brain, breast, lung, and other cancer issues.
SCOPE & PERFORMANCE REQUIREMENTS: The scope of services provided will include:
The vendor-trained Field Engineer will perform corrective maintenance on EE # 226991, which is currently down. The vendor will perform the corrective maintenance on site in the C-arm IR department at West Roxbury location. In the event that the scanner system is found to require any kind of additional repair service beyond the scope of the corrective maintenance, the vendor will reach out to Clinical Engineering and procure written authorization to proceed w/ any such repair.
At the completion of the corrective maintenance service, the vendor will certify that the IR C-arm system is in full working order and performing in conformity to all OEM safety and functional standards. The Vendor will provide a complete service report detailing all repair and testing performed on the scanner.
DELIVERABLES: The following list itemizes the deliverables that are expected to be provided through this procurement Vendor will perform a corrective Maintenance service on ARTIS Q Siemens C-arm (EE226991) including all system components. The above services will be performed on site, in the IR department at the West Roxbury campus of VA Boston. Vendor will perform full safety and functionality testing (to all OEM standards) of this medical device system during the course of this corrective maintenance service.
Vendor will provide a complete service report to Clinical Engineering detailing results of all corrective maintenance service actions and test results performed during this service activity.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 29, 2026
Special notice
Due July 31, 2026 at 4:30 PM EDT. SAM.gov, notice 78749ce512a84c45832fcd660f3dc93f
Points of contact
- Manases Cabrera, Contracting Officermanases.cabrera@va.gov781-687-4418
Also open from this buyer
- Ultrasound System and Linear ProbesSources soughtNAICS 334510Rhode Island36C24126Q0795Closes todaySep 16
- Intent to Sole Source: Advanced Vevo F2xc Imaging SystemPresolicitationNAICS 33451636C24126Q0829Closes tomorrowSep 17
- Repair of Water Storage Tank Leaking Seams at the Northampton VA Medical CenterCombined synopsis and solicitationSmall businessNAICS 811310Massachusetts36C24126Q0820Closes tomorrowSep 17
- Sorna CD Burner Acquisition Modification P0003 Combined Synopsis: SD/VOSB Set-Aside/RFQ Extension to 09/18/26 at 11:00 AM EDT Review Request for Brand NameCombined synopsis and solicitationSDVOSBNAICS 33411836C24126Q0731Closes in 2 daysSep 18
- VSCAN AIR CL and SL Portable Handheld Ultrasounds: INTENT TO SOLE SOURCE: SDVOSB Sole Source VAAR 819.7008/Brand Name FAR 12.102-1(a)PresolicitationSDVOSB sole sourceNAICS 334510Maine36C241Q0777Closes in 2 daysSep 18