Special notice, service-disabled veteran-owned small business set-aside
Upgrade Central Chiller Plant and DDC Controls
W912PL24B0004
Department of the Army, W075 Endist Los Angeles. Plumbing, Heating, and Air-Conditioning Contractors.
Response deadline
March 28, 2024 at 5:00 PM EDT
Closed 903 days ago. Posted March 14, 2024. Scheduled to archive April 12, 2024.
Description
As published on SAM.gov.
This project intends to replace the existing Chillers, Upgrade/Refurbish Existing Cooling Towers, Upgrade/Replace the Primary and Secondary Chilled Water Pumps, Condenser Water Pumps, related Piping and Controls, pressure differential Delta P valves in main chilled water lines entering each of the buildings, and interface with existing Johnson Controls Metasys System. The intent of this announcement is to specify brand-name equipment to be included in the design.
The notice of intent will cover only the portion of the acquisition that is the brand name or peculiar to one manufacturer. Use of such descriptions in the design is essential to the Government’s requirements to ensure system compatibility, warranty, and/or training, thereby precluding consideration of a product manufactured by another company. A brief description of each system is listed below.
Energy Management Control System. – The government requires use of Johnson Controls Inc, Metasys Building Automation and Control Systems (Metasys System). This system is the overall system used to control the Heating and Ventilation and Air Conditioning (HVAC) systems in the main hospital building (Building 126) and all surrounding buildings Door Hardware System. – The government requires the use of Schlage Primus Large Format IC (Interchangeable core locks) for security and inventory purposes.
The door hardware system needs to remain uniform and in compliance with the existing key system Security Access System. – The government requires use of Identiv Hirsch Security Access Control Equipment and Identiv Velocity Video Management System security related monitoring systems as they are already deployed throughout the VALBHS campus. Life Safety System. The government requires use of Edwards EST3, Addressable Fire Alarm System.
This system is the Medical Center’s standard for fire alarm systems security related monitoring systems in the main hospital building (Building 126) and all surrounding buildings. Life Safety System. The government requires use of Novec 1230 Extinguishing System. This system is the Medical Center’s standard for fire extinguishing systems and already deployed throughout the VALBHS campus. The following are the essential items requiring the brand name requirements:
a) System Compatibility A non-integrated system comprised of incompatible parts will result in unacceptable delays in fulfilling the VALBHS campus requirements. To maintain proper operations and warranties, the parts used in servicing the equipment should only use approved parts from the manufacturer. A fully integrated system designed to operate and work together optimizes performance. Components from different manufacturers are not always compatible with each other which can lead to challenges during installation and integration. Incompatibilities may result in improper connections, communication failures, or unreliable performance.
b) Warranty It is typical for the work performed on the noted equipment to require a manufacturer certified technician to provide and maintain current warranties. The installation of non-manufacturer parts and the consequent need for certified technicians from multiple manufacturers will result in unacceptable delays and the duplication of maintenance contract costs in fulfilling VALBHS campus requirements.
c) Training. The use of non-manufacturer parts which are not consistent with the current systems would result in substantial duplication of training costs due to the requirement for equipment manufacturer specific training that addresses the proprietary features and needs of operating and maintaining the systems. An integrated system and standardization of equipment will prevent this additional financial burden.
The information identified above is intended to be descriptive of why it is imperative the Brand Name Only equipment and controls are to be used.
Responses to this announcement should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 238220. Please answer the following questions: Provide an alternative to using mentioned equipment, with supporting rationale, that would alleviate the Government’s concerns regarding system compatibility.
Provide an alternative to using mentioned equipment, with supporting rationale, that would alleviate the Government’s concerns regarding warranties. Provide an alternative to using mentioned equipment, with supporting rationale, that would alleviate the Government’s concerns regarding duplication of training costs.
Provide rationale as to how a on non-integrated equipment system will result in a more reliable system (than an integrated system using only aforementioned equipment) to ensure that compatibility and standardization efforts are not impacted. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Special Notice.
Information will only be accepted in writing by e-mail to Contract Specialist Ashley Powell at ashley.s.powell@usace.army.mil and James Costantino at james.m.costantino@usace.army.mil.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
March 14, 2024
Special notice
Due March 28, 2024 at 5:00 PM EDT. SAM.gov, notice d75d9fb48c524d59babced448a463dd8
Points of contact
- Ashley Powellashley.s.powell@usace.army.mil2134523241
- James Costantinojames.m.costantino@usace.army.mil2134523237
Also open from this buyer
- RIO DE FLAG FLOOD CONTROL PROJECT ��������� PHASE 4 LOWER RDF INLETSources soughtW912PL26S0050Closes tomorrowSep 18
- Expand Emergency Power to HVAC SystemsSources soughtW912PL26S0052Closes in 4 daysSep 21
- Rio de Flag Flood Risk Management ProjectSources soughtW912PL26S0051Closes in 4 daysSep 21
- DISASTER RESILIENCY PROGRAM PHASE 3, CREECH AFB, NEVADASolicitationNAICS 236220W912PL26RA027Closes in 7 daysSep 24
- Multiple Award Task Order Contract (MATOC) Healthcare Facility Construction, Repair, and Renovation Services, ArizonaSources soughtW912PL26S0053Closes in 11 daysSep 28