Award notice, total small business set-aside, first published as solicitation
Yearly Fire Inspections
W912ES24Q0045
Department of the Army, W07V Endist ST Paul. All Other Professional, Scientific, and Technical Services.
Awarded
Mississippi Welders Supply Company, Inc.
$36,250.00 obligated so far on USAspending
Description
As published on SAM.gov with the solicitation of March 22, 2024.
Scope of Work – Yearly Fire Inspection Fire Extinguishers, Fire Suppression Systems, and Fire Control Panels Project Description: The US Army Corps of Engineers, Physical Support Branch, requests annual and periodic inspections of all portable fire extinguishers, fixed fire suppression systems, 1 Amrex galley hook fire suppression system and 4 fire control panels. All inspections will be conducted in accordance with NFPA chapters 10 and 17A, OSHA and US Army Corps of Engineers Health and Safety Manual 385?1?1 requirements.
Scope of Work: Line 1-Fountain City Service Base & 5A Warehouse-Table 1 Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers. This inspection shall be completed by 01 May of each calendar year of the contract, including all options.
See attached list for quantities and locations of all extinguishers associated with the Fountain City Service Base. Building 3 (office building) (SIEMENS Cerberus) has a fire control panel that requires inspection, testing, and servicing. The Fountain City Service Base systems list of all extinguishers/systems is below (Table 1).
Line 2-Dredge Goetz-Table 2 Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers and installed systems on the Dredge Goetz Fleet, this inspection shall be completed by 01 July of each calendar year of the contract, including all options.
The quarter’s barge Taggatz has one Amrex galley hood fire suppression system that requires servicing and inspection also. The Warioto (Notifier SFP-2404), General Warren (SIEMENS System 3), Goetz (Notifier AFP-200), and Taggatz (ANSUL AutoPluse IQ-301) all have Fire control panels that require inspection, testing, and servicing. See attached list for quantities and locations of all extinguishers associated with the Goetz Fleet (Table 2).
Line-3:Maintenance & Repair-Table 3 Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers and installed systems on the Maintenance and Repair Fleet. This inspection shall be completed by 01 May of each calendar year of the contract, including all options.
See attached list for quantities and locations of all extinguishers associated with the Maintenance and Repair Fleet (Table 3) The contractor shall create a report that lists any deficiencies that are found that require repairs. This report shall be sent to the Technical Points of Contract. The contractor shall create a report that lists any deficiencies that are found that require repairs. This report shall be sent to the Technical Points of Contact.
Repairs shall not be completed without prior written approval from the Contracting Officer’s Representative (COR) and if the aggerated amount of the repairs exceeds $ 5,000.00 the contractor must have written approval from the Contracting Officer. All repairs must be completed within 10 working days of Contracting Officer’s approval.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- UEI
- XND5HMGR38Y3
- CAGE
- 1B2V2
- Vendor location
- Winona, MN
- Contract
- W912ES24P0086, purchase order
- Obligated
- $36,250.00, potential $66,100
- Actions
- 3 between April 16, 2024 and February 3, 2026
- Competition
- Competed Under SAP, 4 offers received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- Fire Suppression Inspection Services.
- Match
- award number W912ES24P0086 equals the contract number; same awarding office W912ES (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
March 6, 2024
Solicitation
Due March 20, 2024 at 4:00 PM EDT. SAM.gov, notice fde1f3f74810421496a4ef36fe878d55
March 22, 2024
Solicitation
Due March 28, 2024 at 4:00 PM EDT. SAM.gov, notice c5ab05a4310345b79a4e1ab99a353695
April 18, 2024
Award notice, originally solicitation
Awarded to MISSISSIPPI WELDERS SUPPLY COMPANY, Inc. Winona for $66,100. SAM.gov, notice e2e65e7a6b554f0089fee5156d3b5799
Points of contact
- Ben Knutsonbenjamin.t.knutson@usace.army.mil6512905418
- Jesse OnkkaJesse.l.onkka@usace.army.mil
Also open from this buyer
- Collect and Plant Willow Cuttings in Mississippi River Pools 3, 5, and 5ASolicitationSmall businessNAICS 561730W912ES26QA097Closes in 3 daysSep 21
- Blackhawk Park Pre-Fabricated Comfort StationSolicitationNAICS 238120W912ES26QA111Closes in 4 daysSep 22
- LD3 Tree RemovalSolicitationSmall businessNAICS 561730W912ES26QA102Closes in 5 daysSep 23
- Oil PurifierSolicitationSmall businessNAICS 333998W912ES26QA113Closes in 5 daysSep 23
- Crane LMI System, Barge Integration and Components InstallationSolicitationSmall businessNAICS 333120W912ES26QA112Closes in 7 daysSep 25