Special notice, first published as sources sought
Notice of Intent: Monaco fire alarm for Manufacturing Lab Addition Between B331 B332 and Renovations, Lakehurst Naval Base, Joint Base-MDL, New Jersey
W912DS25S0015
Department of the Army, W2SD Endist New York. Commercial and Institutional Building Construction.
Response deadline
February 6, 2025 at 2:00 PM EST
Closed 588 days ago. Posted January 30, 2025, first published January 22, 2025. Scheduled to archive January 30, 2025.
Description
As published on SAM.gov.
Ntoice of Intent announcement to:
A. To notify potential Offerors of the Governments intent to solicit a brand name(s) only component for this project. B. To identify potential sources that can provide an equivalent to the brand name only item. C. Notification of the Army’s intent to solicit brand name components as described below. Monaco Fire Alarm System (estimated TOTAL cost = $315,000):
(1) MSBL124029 Additive Lab B331/B332 Renovations (estimated cost = $45,000):
(2) MSBL223000 EV Charging Infrastructure (estimated cost = $45,000):
(3) PN 104300 UAS Warehouse (estimated cost = $45,000): Currently, all buildings at Joint Base McGuire-Dix-Lakehurst requiring fire alarm and mass notification are provided with the Monaco MAAP-X fire alarm/mass notification panel and associated alarm signaling equipment. This system utilizes the Monaco MAAP-X transceiver to communicate with the Monaco D21 system at the Fire Department, which is a closed source system that utilizes proprietary communication protocols.
The Base Fire Protection Standards requires that all buildings on base shall have a Monaco addressable fire alarm system. Each of the projects listed above will require a MAAP (+) with integral transceiver since it is fire alarm only. If Monaco systems are not used, then the fire alarm panel and associated alarm signaling equipment will not be able to communicate with the base reporting system.
This will jeopardize the safety of the building occupants since the fire department will not be able to assist in a timely manner if a fire arises. Monaco MAAP X or MAAP (+) panels are therefore necessary in order to ensure compatibility with the current installation-wide network.
Attempting to integrate parts outside the current network poses unacceptable risks, because it would negatively affect the system’s ability to maintain proper communication with each of the projects fire protection system and the rest of the joint base, risking the lives of occupants in the case of a fire.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
January 22, 2025
Sources sought
Jetty Rehabilitation of Cheesequake Creek, NJ Federal Navigation Project
Due February 24, 2025 at 2:00 PM EST. SAM.gov, notice 96ce86dcb5f242819936737f6b92ecab
January 23, 2025
Sources sought
Jetty Rehabilitation of Cheesequake Creek, NJ Federal Navigation Project
Due February 6, 2025 at 2:00 PM EST. SAM.gov, notice a578d411af4744149ce97735ff1be01e
January 30, 2025
Special notice, originally sources sought
Due February 14, 2025 at 2:00 PM EST. SAM.gov, notice 1bd0c23b75484cba911cfb17ff780c92
January 30, 2025
Special notice
Due February 14, 2025 at 2:00 PM EST. SAM.gov, notice 8c8faa2961e84e03b013308d329d6064
Points of contact
- Nicholas P. Emanuelnicholas.p.emanuel@usace.army.mil
Also open from this buyer
- US Armed Forces Career Center - 3,750 RSF Rome NYPresolicitationNAICS 53131Rome, NYDACA51-5-26-003Closes in 4 daysSep 21
- DeLong Pier RepairPresolicitationNAICS 237990W912DS26BA035Closes in 8 daysSep 25
- Construction of the Power Generation with Microgrid at Joint Base McGuire-Dix-Lakehurst (JBMDL), New Hanover, NJSolicitationNAICS 236220New JerseyW912DS26BA032Closes in 11 daysSep 28
- Pituffik Space Base Project Delivery Method Market Research QuestionnaireSources soughtW912DS26S0045Closes in 15 daysOct 2