Combined synopsis and solicitation, total small business set-aside

Plate Reader

W911S226U3818

Department of the Army, W6QM Micc-Ft Drum. Analytical Laboratory Instrument Manufacturing.

Response deadline

August 6, 2026 at 1:00 PM EDT

Closed 87 days ago. Posted July 28, 2026, first published July 24, 2026. Scheduled to archive July 28, 2027.

Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities

This one closed in 2026

39 like it are open now in analytical laboratory instrument manufacturing

All 39 open in analytical laboratory instrument manufacturing

Description

As published on SAM.gov.

Amended to include set aside code. We require an instrument that can acquire real-time data from multiple modes of measurement, including monochromator-based fluorescence, UV/Vis absorbance, and luminescence. We require the following: linear Variable Monochromator, permitting tunable band passes up to 100nm; a tunable dichroic mirror permitting air-based light path for monochromator without light guides or fiberoptics; auto ranging of detector sensitivity and gain for fluorescence measurements below 760,000,000-counts; enhanced Dynamic Range autoranging of detector sensitivity in less than 0.1s; absorbance based on a dedicated spectrometer, not a monochromator. Complete UV/Vis absorbance spectrum from 220nm-1000nm at 1nm resolution in less than 0.5s with all wavelengths captured simultaneously with a diode array; heated optics. A heated optical head means that incubated microplate wells remain in a uniform temperature environment even during detection. The instrument should have a temperature controller than can go up to 45 �C, bottom reading, two reagent injectors for automated injection for initiating kinetic events and flash luminescence, and an atmospheric control unit with software-controlled CO2 andO2 concentrations for cell culture at 5% CO2. The unit should come with software for data visualization and analysis.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 24, 2026

    Combined synopsis and solicitation

    Due August 6, 2026 at 1:00 PM EDT. SAM.gov, notice aa58e6e18ddf4844ad97cb4e7864fff4

    2 revisions on SAM
    • July 28, 2026: publish, combined synopsis and solicitation
    • July 24, 2026: publish, combined synopsis and solicitation
  2. July 28, 2026

    Combined synopsis and solicitation

    Due August 6, 2026 at 1:00 PM EDT. SAM.gov, notice 84028db1068348db8aab9f035b202a1b

    2 revisions on SAM
    • July 28, 2026: publish, combined synopsis and solicitation
    • July 24, 2026: publish, combined synopsis and solicitation

Points of contact