Skip to content
  • 8,085 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell Abierto what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and Abierto tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans
AbiertoGet started

Combined synopsis and solicitation, total small business set-aside

AIR COMPRESSOR CHILLER

W911S225U1837

Department of the Army, W6QM Micc-Ft Drum. Air and Gas Compressor Manufacturing.

Awarded

Alzamin USA LLC

$40,397.50 obligated so far on USAspending

Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities

This one was awarded in 2025

20 like it are open now in air and gas compressor manufacturing

  • Compressor Unit

    US Coast Guard, Cg-Sea-C22

    SolicitationSmall businessNAICS 333912Anywhere in the US70ZU0227Q40003B00
    Closes in 4 daysNov 11
  • CYLINDER,RECIPROCATING

    Defense Logistics Agency, DLA Weapons Support

    Combined synopsis and solicitationSmall businessNAICS 333912Anywhere in the USSPE7M127T1670
    Closes in 3 daysNov 9
  • LINER,COMPRESSOR

    Defense Logistics Agency, DLA Weapons Support

    Combined synopsis and solicitationNAICS 333912Anywhere in the USSPE7M127T1758
    Closes in 3 daysNov 9

All 20 open in air and gas compressor manufacturing

Description

As published on SAM.gov.

CHILLER UNIT COMPONENTS FOR 760 CFM SULLAIRE AIR COMPRESSOR1 Model AFC44CB-0C41 General Air Products, Inc. Fluid Cooler at 427,538 Btu/Hr total at a flow of 46.4 gpm total with a 5� F approach, 40% propylene glycol solution and a design ambient of 85� F. Coolers will have A350 Johnson controls for fan cycling and 460v/3/60Hz electrical equipment and offer the following features as standard 4 direct drive 1.5 HP propeller fans with vinyl coated fan guards, weather resistant motors with sealed bearings, internal overload protection, and hardware designed for outdoor duty. Access door panels at each fan motor, vent and drain connection and corrosion resistant construction.1 Model FPSBD44A, 3 HP Fluid Pumping Station for 40 PSI and to be wired 460v/3/60Hz with a 120v control circuit. Pumping station to be completely pre-plumbed and pre-wired with TEFC type motors and a NEMA 4 steel control panel. The unit will have a close-coupled centrifugal pump with expansion tank, temperature and pressure gauges, check valves and shut off safety valves plus a steel base as standard. This unit will be a Duplex design.1 Model MVD75, 1.5? 75 degree thermostatic mixing valve.1 TC3060, Trim Cooler, to trim system on days over 85� F ambient.1 Model WV125, 1.25? Trim water modulating valve. The following document provides the requirements and specifications for the chiller unit for 2 Sullaire air compressors. Applicable Documents 1. Standards and Regulations: 2. Additional Documents Requirements 3. General Requirements This section provides the design specification requirements for the B190 compressor chiller unit. a. The chiller unit will need to be sized to provide water cooling to the heat exchangers on a 150 HP, 100 PSI Gardner Denver screw compressor that can produce 760 CFM. i. The compressors are plumbed into an oil cooler for the outgoing compressed air This section provides specific requirements for the B190 compressor chiller unit equipment requested. a. Fluid Fan Bank Cooler i. General Air Products Model AFC44CB-0C41, or equivalent ii. 427,538 Btu/ Hr total at flow rate of 46.4 GPM iii. To be operated with a 40% propylene glycol solution iv. A350 Johnson controls for fan cooling v. 460V/ 3 Ph/ 60 Hz vi. 4 direct drive 1.5 hp propeller fans with fan guards vii. Sealed bearings viii. Internal overload protection ix. Access panels for each motor x. Vent and drain connections b. Duplex Pumping station i. General Air Products Model FPSBD44A, or equivalent ii. 3 HP for 40 PSI iii. 460V/3Ph/60 Hz iv. 120V control circuit v. Pre-plumbed and wired with TEFC motors vi. NEMA 4 control panel vii. Close-coupled centrifugal pump with expansion tank\ viii. Temperature and pressure gauges ix. Check valves and shut-off valves c. 1.5? 75 degree Thermostatic Mixing valve i. General Air Products Model MVD75, or equivalent d. Trim Cooler for days over 85 degF ambient i. General Air Products Model TC3060, or equivalent e. Trim Water Modulating Valve i. General Air Products Model WV125, or equivalent Proposal, Reviews, Drawings, Documentation, and Data

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
NGFKT5X3QKF6
CAGE
8L3T6
Vendor location
Glen Burnie, MD
Contract
W911S226PA002, purchase order
Obligated
$40,397.50
Actions
2 between October 21, 2025 and January 5, 2026
Competition
Competed Under SAP, 4 offers received
Set-aside reported
Small Business Set Aside - Total
Described as
S2P2: Air Compressor Chiller Sol W911s225up1837
Match
solicitation number W911S225U1837 equals the FPDS solicitation identifier; same awarding office W911S2 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. September 9, 2025

    Combined synopsis and solicitation

    Due September 16, 2025 at 12:00 PM EDT. SAM.gov, notice 4d2bb869a0934913936d48ba4a98d632

    1 revisions on SAM
    • September 9, 2025: publish, combined synopsis and solicitation

Points of contact