Skip to content
  • 7,004 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell Abierto what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and Abierto tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans
AbiertoGet started

Combined synopsis and solicitation, total small business set-aside

120-155mm Cannon Laser Bore/ Chamber Add-on Kit

W911S225U0516

Department of the Army, W6QM Micc-Ft Drum. Other Measuring and Controlling Device Manufacturing.

Response deadline

April 21, 2025 at 6:00 PM EDT

Closed 562 days ago. Posted April 14, 2025, first published March 12, 2025. Scheduled to archive April 14, 2026.

Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities

This one closed in 2025

53 like it are open now in other measuring and controlling device manufacturing

  • TRANSMITTER,PRESSUR

    Defense Logistics Agency, DLA Aviation

    Combined synopsis and solicitationWOSBNAICS 334519Anywhere in the USSPE4A627T7149
    Closes tomorrowNov 4
  • CALIBRATOR SET,RADIAC

    Defense Logistics Agency, DLA Weapons Support

    Combined synopsis and solicitationSmall businessNAICS 334519Anywhere in the USSPE7M127Q0125
    Closes tomorrowNov 4
  • tTEM V2 SYSTEM UPGRADE

    Departmental Offices, Reclamation Contracting Activity

    Sources soughtNAICS 334519Anywhere in the US140RR027Q0008
    Closes tomorrowNov 5

All 53 open in other measuring and controlling device manufacturing

Description

As published on SAM.gov.

New 120-155mm Cannon Laser Bore Chamber Add-on Kit capability for 120-155mm cannon gun tubes. This acquisition shall be capable of use for: Precision non-contact bore measurement of 120-155 mm cannon smooth and rifle gun tubes.

Measurement to the end of the muzzle with a guide tube adaptor that attaches to the muzzle, for supporting none-contact gauge and rigid or self-propelled delivery unit Laser cannon tube bore and chamber gauging kit shall employ a set of opposed high-resolution sensors that are automatically none-contact the bore chamber along its length to muzzle end of cannon tube.1.

The 120mm Cannon Laser Add-on Bore Gauging Kit shall be operated as a complete turn-key unit and include the following major components:120mm Cannon Bore Chamber Add-on kit Guide tube assembly Certified calibration ring (5 steps) Laser Bore Chamber Calibration Workspace Software2.

The 155mm Cannon Laser Add-on Bore Gauging Kit shall be operated as a complete turn-key unit and include the following major components:155mm Cannon Bore Chamber Add-on kit Guide tube assembly Certified calibration ring (5 steps) Laser Bore Chamber Calibration Workspace Software3.

The Laser bore chamber scanning modules shall meet the following specifications Axial scan resolution: 0.25mm (0.01 inch) minimum Rotary scan resolution: 0.1mm (0.004 inch) minimum Sensor Resolution: 0.005mm (0.00025 inch)Laser spot size: 0.050mm (0.002 inch) minimum Measurement repeatability: 0.012mm (0.0005 inch)Measurement Accuracy: minimum of 0.025mm (0.001 inch) in bore and 0.05mm (0.002?) in bore chamber Angular Sampling Resolution: Variable ? up to 0.1 degrees per sample (3,600 samples per revolution)Measuring Range (diameter): Chamber Bore Size Minimum Range Maximum Range120mm 4.7000 in 6.3000 in155mm 6.1950 in 6.8000in 4.Each Calibration Ring shall have five steps (diameters) minimum within the center 75% of the range of the gauge The Calibration Rings shall be measured with a NIST-traceable.

A2LA Accredited, ISO 17025 and ANS/INCL Z540-1-1994 standards5.Automatic Sensor Calibration software shall be capable of conducting an automatic calibration routine Calibration Software shall provide a Pass/Fail display of calibration test results If the calibration fails, the software shall automatically calculate corrected calibration parameters Calibration software shall allow the operator to manually adjust offset and slope of the calibration algorithm6.

Data analysis shall be supported by existing analysis software, with modification if required to meet the requirements in this specification Analysis modules for post processing of data including but not limited to calculating: land and groove diameter, area, statistics, reference subtraction, rotate data, remove centering offset, remove undefined data, remove bad data, variable median filter, averaging filter

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. March 12, 2025

    Combined synopsis and solicitation

    120-155mm Cannon Laser Bore/ Chamber Add-on Kit to Rigid Delivery Stage Contract W9124R24P0005

    Due March 19, 2025 at 3:55 PM EDT. SAM.gov, notice cb651f31539742b2a43c6ccebb1100ba

  2. March 13, 2025

    Combined synopsis and solicitation

    120-155mm Cannon Laser Bore/ Chamber Add-on Kit to Rigid Delivery Stage Contract W9124R24P0005

    Due March 19, 2025 at 3:55 PM EDT. SAM.gov, notice 2c7730e49c404745b020c793cb24a009

  3. March 13, 2025

    Combined synopsis and solicitation

    120-155mm Cannon Laser Bore/ Chamber Add-on Kit to Rigid Delivery Stage Contract W9124R24P0005

    Due March 19, 2025 at 3:55 PM EDT. SAM.gov, notice 9170e2ab36fa49a6bcba34ab9550acc5

  4. April 14, 2025

    Combined synopsis and solicitation

    Due April 21, 2025 at 6:00 PM EDT. SAM.gov, notice 35f7e0a907c145a8ba3b6fc7a1863b95

Points of contact