Combined synopsis and solicitation, total small business set-aside
Winch Test Stand
W911RQ26QA007
Department of the Army, W6QK ACC Rrad. Commercial and Service Industry Machinery Manufacturing.
Response deadline
February 12, 2026 at 2:00 PM EST
Closed 263 days ago. Posted February 5, 2026. Scheduled to archive February 27, 2026.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2026
50 like it are open now in commercial and service industry machinery manufacturing
- Project Name: Veteran Self-Employment Plan – AI Vending Machines; Project Number: None; and Station Location: Sioux Falls, South Dakota, Veterans Affairs Regional Office (VARO), Veteran Readiness and Employment (VR&E) Division
Department of Veterans Affairs, Veterans Benefits Admin
SolicitationSDVOSBNAICS 333310Anywhere in the US36C10D27Q0007Closes todayNov 2 - RETAINER,BATTERY CA
Defense Logistics Agency, DLA Weapons Support
Combined synopsis and solicitationNAICS 333310Anywhere in the USSPE7M127U0867Closes tomorrowNov 2 - DISK,FRICTION
Defense Logistics Agency, DLA Weapons Support
Combined synopsis and solicitationSmall businessNAICS 333310Anywhere in the USSPE7LX27U0253Closes tomorrowNov 2
All 50 open in commercial and service industry machinery manufacturing
Description
As published on SAM.gov.
- General: This description is for the purchase of 1 each Winch Test Stand for Heavy Tactical.
- Salient Characteristics:
- 2005-WINCHTEST60HP or equal
- Electric Motor: 60hp TEFC 364/5TC 208-230/460, 3 phase, 60 hz 1800 rpm
- Hydraulic Pump: 3.19c.i.r. Gear Pump, 3500 psi Continuous Pressure, 23.6 gpm
- Directional Control Valve: single bank, 4500psi rated, 2-position detented, w/built in relief valve, 1800-3600psi settings. (set to 3500psi)
- Two 4500psi shut off valves for in/out
- Electric Fan Cooled Heat Exchanger, 208-230/460, 3ph, 60psi bypass.
- 5000psi pressure gauge, return line filterassembly, filter gauge, suction strainer, sight level gauge, suction cut/off valve, c-face pump/motor mount, magnaloy coupling
- Mounted to 120 gallon reservoir with baffle, extended deck, raised frame for heat exchanger, valve support, all necessary adapter fittings and hoses to make operational.
- Delivery: Must be delivered to Red River Army Depot, 100 James Carlow Dr., Texarkana, Tx 75507, Bldg. 412E.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Draft Combined Synopsis Winch Test Stand draft.pdf232 KB, February 5, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
February 5, 2026
Combined synopsis and solicitation
Due February 12, 2026 at 2:00 PM EST. SAM.gov, notice 3c568baad50846bdb199817907573f8a
2 revisions on SAM
- February 9, 2026: publish, combined synopsis and solicitation
- February 5, 2026: publish, combined synopsis and solicitation
Points of contact
- James Whitejames.w.white13.civ@army.mil5206916662
- Christopher L. Johnstonchristopher.l.johnston20.civ@army.mil5715881511