Solicitation, service-disabled veteran-owned small business set-aside
Exam Lights Recessed
W81K0026QA152
Department of the Army, W40M MRC0 West. Surgical Appliance and Supplies Manufacturing.
Response deadline
May 8, 2026 at 1:00 PM EDT
Closed 177 days ago. Posted April 28, 2026. Scheduled to archive May 23, 2026.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2026
23 like it are open now in surgical appliance and supplies manufacturing
- MEDTRONIC INFINITY THORACIC TRAY
Department of Veterans Affairs, 246-Network Contracting Office 6
Sources soughtNAICS 339113Anywhere in the US36C24626Q1101Closes todayNov 1 - RESPIRATOR HOOD UNITS
Department of the Army, W6QM Micc-Ft Drum
Combined synopsis and solicitationNAICS 339113Anywhere in the USW911S227U0050Closes tomorrowNov 2 - Smart Hospital Stretchers for the ambulatory procedural unit at the Hudson Valley, Castle Point VAMC.
Department of Veterans Affairs, 242-Network Contract Office 02
Closes tomorrowNov 2
All 23 open in surgical appliance and supplies manufacturing
Description
As published on SAM.gov.
Clinical Salient Requirements:
The lighting system must be operable without compromising the sterile field required for vaginal deliveries.
1.The light must provide bright, focused illumination deep into the birth canal.
2.The illumination must be homogenous and minimize shadows cast by the clinical team.
3.The light quality must allow for accurate assessment of tissue color.
4.Technological Salient Requirements:
Server Requirements: The system must allow for precise, remote aiming of the light beam from a distance via remote or wand.
The light fixture must be fully recessed into a standard ceiling grid.
A. The light must provide a minimum level of brightness at a standard working distance. 14,000 LUX at 3 meters and 49,000 LUX at 1 meter.
B. A single controller must be able to operate multiple light heads simultaneously.
C. The light source must be energy-efficient, long-lasting, and produce minimal heat.
D. Capture Workstation Requirements: N/A
E. System Requirement:
It must be compatible with standard hospital ceiling heights and grid systems.
Must operate on standard hospital electrical systems.
Must include both a wall-mounted control panel and a handheld wand.
5. Other Requirements:
Installation, inspection and warranty certification of recessed lighting system, single mount or up to two (2) flush ceiling mounted exam system. Includes pre-installation walk through, installation and full functional testing of the system. Does not include electrical wiring, structure or wall control unit rough in. Pricing does not include weekend/after-hours work.
A. Direct-To-Site Setup Service: inspecting products for damage and coordinating replacement if required.
B. Delivery is requested Monday through Friday between the hours of 0800-1500.
C. Installation and removal shall take place during any time of day at address: 1650 Cochrane Circle, BLDG 7500, Fort Carson, CO 80913.
D. Removal of existing equipment from site located in building number: 7500. Coordination of the disposition of existing equipment is the responsibility of the vendor.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Solicitation - W81K0026QA152.pdf3.2 MB, April 28, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 28, 2026
Solicitation, originally sources sought
Due May 8, 2026 at 1:00 PM EDT. SAM.gov, notice fc3331ff60764cd0871d03dd4c314921
2 revisions on SAM
- April 28, 2026: publish, solicitation
- April 20, 2026: publish, sources sought
Points of contact
- Joseph Floresjoseph.a.flores.civ@health.mil