Sources sought
Industrial Vacuums
W15BW9-24-X-7890
Department of the Army, W4MK CCDC Armaments Center. All Other Industrial Machinery Manufacturing.
Response deadline
May 10, 2024 at 12:00 PM EDT
Closed 906 days ago. Posted April 25, 2024. Scheduled to archive May 25, 2024.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2024
5 like it are open now in all other industrial machinery manufacturing
- Prometheus Atomic Layer Deposition System
Department of the Navy, Naval Air Warfare Center
PresolicitationNAICS 333248Anywhere in the USN6893626SIMACQD550000E5500000441Closes tomorrowNov 3 - Radia Paint Shakers
Department of the Army, W6QK ACC Anad
SolicitationNAICS 333248Anywhere in the USW911KF27QA007Closes in 7 daysNov 9 - HOIST,HOOK
Defense Logistics Agency, DLA Troop Support
Combined synopsis and solicitationSmall businessNAICS 333248Anywhere in the USSPE8EE27T0334Closes in 8 daysNov 9
Description
As published on SAM.gov.
This is a Sources Sought (SS) issued by the Army Combat Capabilities Development Command (DEVCOM), Armaments Center (AC), Munitions Engineering & Technology Center (METC) and Aeroballistics Division. This effort is for information to plan a potential acquisition strategy and contract for a vacuum system.
The effort supports a wind tunnel facility in building 266. Responders to this SS notice are asked to provide statements with the following information related to meeting requirements: A narrative explaining the company’s background, and past/current experience relevant to furnishing and installing any of the aforementioned systems that can create exit conditions of -14.5 PSI (~10 torr or less, 0.1PSIA) for 9-inch test section wind tunnel.
There is 120,000 gallons of air storage (rated 190Psi) available to drive the system. Compressors of the current wind tunnel facility operate at no more than 350 PSI. For a Vacuum System, an estimated 2,480 cubic feet, vacuum rated storage tank is required. The tank will need to withstand vacuum conditions internally, and barometric conditions externally. The pumps for this system should be able to evacuate the tank in about 30~45 minutes.
The Vacuum Blowers need to minimize pressure build up in the tank over a 40 second runtime (objective runtime, 20 second threshold). The system must be able to withstand temperatures as high as a) the outlet temperature of the gas for -14.5 PSI (.01 PSIA) case will be 800 0°F and b) the outlet temperature of the gas for -13.0 PSI (1.8 PSIA) case will be 620°F. Ability to provide training on maintenance, safety, and other handling requirements of the system. Request that all responses included the following information:
Filly Company Name (Legal Entity):
Cage Code: Website (if applicable):