Combined synopsis and solicitation, total small business set-aside
UPS Upgrade Bldg 4
SPS-USCG-250003
US Coast Guard, Base Seattle. Battery Manufacturing.
Awarded
$139,518.48 obligated so far on USAspending
Description
As published on SAM.gov.
Update 1 to questions answered: The GAO states the following when BAA applies: “(1) the procurement must be intended for public use within the United States; and (2) the items to be procured or the materials from which they are manufactured must be present in the United States in sufficient and reasonably available commercial quantities of a satisfactory quality.
The provisions of the act may be waived if the head of the procuring agency determines the act to be inconsistent with the public interest or the cost of acquiring the domestic product is unreasonable.” If these do not apply to our case, then we can go open market. 2. We will use the existing transformers unless they determine there is a need to have the supply power to the unit stepped down. 3. We will support any day of the week. Also, we would like to have a week, or 2 weeks’ notice prior to any requested shutdowns. UPDATED!!
DESCRIPTION OF SERVICES: The Contractor shall provide all personnel, management, supervision, materials, tools, supplies, equipment, transportation, labor, and other items and services necessary to replace a total of two (2) Uninterruptible Power Supply (UPS) systems in Building 4 room #135 and Building #4 room #339, at Base Seattle. The contractor must perform to the standards in this contract. All work shall comply with all applicable codes, along with Federal, State and local regulations. .
This notice is a combined synopsis/solicitation for a commercial products and commercial services in accordance with Federal Acquisition Regulation Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes a public solicitation. Please read this entire notice, the instructions herein, and the attachment documents carefully. This acquisition is on a Small Business Set-Aside only.
HOW TO RESPOND: To compete for this project, interested parties must be registered in SAM (System for Award Management) prior to close of this solicitation. https://www.sam.gov/portal/public/SAM/. The vendors SAM registration must be in an “ACTIVE” status prior to award. Vendors must ensure that the above listed NAICS codes are listed on their SAM registration to perform this type of service.
COST PROPOSALS: The contract will be awarded using simplified acquisition procedures in accordance with FAR part 13 and part 15 provide Firm Fixed-Price “broken out by labor hours, labor category, materials, and other direct costs”. Offerors must submit the proposal to Elizabeth Meister e-mail: elizabeth.a.meister@uscg.mil.
EVALUATION CRITERIA: The government will award a contract resulting from this request for quote (RFQ) to the responsible offeror whose offer conforming to the RFQ is the Lowest price Technically Acceptable (LPTA) quote. The lowest priced quote will be evaluated on technical acceptability, if it is found to be acceptable, an award will be made. If it is found to be unacceptable, the next lowest price will be evaluated. This process will continue until a technically acceptable offer is identified.
Description of Work Required: Contractor shall replace two (2) UPS Systems. Contractor to remove and dispose of existing UPS system located in Building 4 room #135, and UPS system in Room #339, and supply and install new UPS systems with new lithium-ion batteries. Contractor to replace system with Brand Name or approved equal. Existing UPS Manufacturer and Model for both systems- Vertiv Liebert NPower 100 kVA 480 Volt 3-phase. Incoming voltage to UPS is 480V. After UPS, voltage steps down to 208V. It is estimated that the capacity of the existing UPS system in each room is too large. Contractor is to present a UPS system design to the KO for approval prior to purchase and installation.
Suggested UPS Systems:
Manufacturer:
Vertiv Liebert EXM 480V Manufacturer:
Eaton 93PM 480V Manufacturer: Schneider Electric Galaxy VS 480V Existing load on UPS System in room #135 is 21% and room #339 is approximately 26%. New UPS is to be sized to existing load capacity plus 25% increase for future expansion. New UPS must fit within dimensions of existing room. New UPS system is to supply power to connected equipment for a runtime of 60 minutes.
UPS Battery Type: Lithium Ion, Flame retardant case and cover meet UL 1778 standards. UPS system complies with the most recent version of following standards: UL1778, UL924, UL1989 and UL94 V-2, BS 6290-4, IEC-60896-2 as well as standards referenced in Section 4, and all relevant Federal, State, and local standards and codes. All materials and parts supplied by the contractor in this SOW shall be new, are fully compatible with the entire UPS system, and comply with the UPS manufacturer’s specifications and installation standards. All materials and parts shall be approved by the KO prior to installation. Submit quotes to the following e-mail address by the offer due date and time:
Attn:
Elizabeth Meister E-Mail Address: Elizabeth.a.meister@uscg.mil with solicitation RFQ number SPS-USCG-250003 in subject line.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Atlantic for Services Inc.
- UEI
- DY1NN7DAGFF4
- CAGE
- 9VEW8
- Vendor location
- Stoneham, MA
- Contract
- 70Z03325PSEAT0078, purchase order
- Obligated
- $139,518.48
- Actions
- 4 between February 27, 2025 and June 26, 2026
- Competition
- Competed Under SAP, 9 offers received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- Uninterrupted Power Supply Upgrade and Installation for Sector Puget Sound Building 4
- Match
- solicitation number SPSUSCG250003 equals the FPDS solicitation identifier; same awarding office 70Z033 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
December 30, 2024
Combined synopsis and solicitation
Due January 9, 2025 at 2:00 PM EST. SAM.gov, notice 8b643c9e75034211bf661b508d6170fe
January 3, 2025
Combined synopsis and solicitation
Due January 10, 2025 at 4:00 PM EST. SAM.gov, notice ac51073697924ee29338f8ce07e56408
January 3, 2025
Combined synopsis and solicitation
Due January 10, 2025 at 4:00 PM EST. SAM.gov, notice b6fce4a560024879859da3f1515a5e85
January 3, 2025
Combined synopsis and solicitation
Due January 10, 2025 at 4:00 PM EST. SAM.gov, notice df8ed206638d4eb3bbff4416b4457e86
January 6, 2025
Combined synopsis and solicitation
Due January 10, 2025 at 4:00 PM EST. SAM.gov, notice d20a8fe6e6f243e9991092c3ac2628fe
January 6, 2025
Combined synopsis and solicitation
Due January 10, 2025 at 4:00 PM EST. SAM.gov, notice ec6ad2d7aa774fcdb88c97474d844786
January 8, 2025
Combined synopsis and solicitation
Due January 15, 2025 at 4:00 PM EST. SAM.gov, notice 643ca11c364f4ec2af1abd65d959a2a7
January 13, 2025
Combined synopsis and solicitation
Due January 15, 2025 at 4:00 PM EST. SAM.gov, notice 6605f9944d134f178be4e795dafc76ea
February 3, 2025
Combined synopsis and solicitation
Due February 10, 2025 at 4:00 PM EST. SAM.gov, notice 1eb0e4d08fbe4f8086969f9907993060
February 3, 2025
Combined synopsis and solicitation
Due February 10, 2025 at 4:00 PM EST. SAM.gov, notice 51e72c73b9dd4e72bcf9f559b76b8cf3
February 4, 2025
Combined synopsis and solicitation
Due February 10, 2025 at 4:00 PM EST. SAM.gov, notice 7383f45df8594264848af959262bcd7c
Points of contact
- Elizabeth Meisterelizabeth.a.meister@uscg.mil2062176145
Also open from this buyer
- Replace Building Boiler at USCG North Bend, ORCombined synopsis and solicitationSmall businessNAICS 238220North Bend, OR70Z033QSEAT0120Closes in 2 daysSep 21
- Repair Aircraft Hangar Apron Concrete - Air Station North BendCombined synopsis and solicitationSmall businessNAICS 237310North Bend, OR70Z033Q2027601Closes in 2 daysSep 21
- U.S. Coast Guard Air Station Port Angeles Main Gate Replacement - Amendment 02Combined synopsis and solicitationSmall businessNAICS 238990Port Angeles, WA70Z03326Q201900012Closes in 4 daysSep 23
- Base Seattle Fire Alarm Confidence TestingCombined synopsis and solicitationSmall businessNAICS 561621Seattle, WA70Z03326QSEAT32798Closes in 9 daysSep 28