Solicitation, first published as special notice

Electronic Autocollimator

PANRSA-26-P-0000-033791

Department of the Army, W6QK ACC-RSA. Analytical Laboratory Instrument Manufacturing.

Response deadline

August 21, 2026 at 1:00 PM EDT

Closed 72 days ago. Posted August 7, 2026, first published March 17, 2026. Scheduled to archive September 5, 2026.

Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities

This one closed in 2026

39 like it are open now in analytical laboratory instrument manufacturing

All 39 open in analytical laboratory instrument manufacturing

Description

As published on SAM.gov.

The U.S. Army TMDE Activity (USATA) has a requirement to procure a brand name purchase of two (2) Electronic Autocollimator that will be used for angle measurements parameter for the calibration of angular gage blocks, optical prisms, optical polygons, and optical wedges. The increased accuracy will eventually allow the APSL to lower its measurement uncertainties for angular calibrations and provide a better Test to Uncertainty ratio for the secondary reference labs. The autocollimators must have an accuracy better than 0.05 arcseconds with a resolution of less than 0.01 arcseconds, and a measurement range greater than ±100 arcseconds. They must also have dual axis measurement capability, have a relatively small footprint: approximately no larger than 12in by 8in, and an ISO 17025 accredited calibration. This item shall be delivered to the Army Primary Standards Laboratory (APSL), Building 5435 Fowler Road, Redstone Arsenal, AL. The Electronic Autocollimator shall include the following specifications or equivalent (if not brand name):


Model 229 923 ELCOMAT HR
Qty:2
High Resolution Electronic Autocollimator
- Dual axis
- Fully automatic, software-controlled operations
- Resolution: 0.005 arcsec
- Absolute accuracy:
±0.01 arcsec over any 10 arcsec range
±0.03 arcsec over total measuring range
- Measuring range: +/- 150 arcsec
- acquisition range: +/- 600 arcsec
- control-/display unit CModul HR
- Interface RS 232/USB
- software interface INCOLINK
- AC-viewfinder prism
- DAkkS Calibration

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. March 17, 2026

    Special notice

    Due March 31, 2026 at 2:00 PM EDT. SAM.gov, notice 3c4afc45fb294c74a7769d1264725100

    1 revisions on SAM
    • March 17, 2026: publish, special notice
  2. August 7, 2026

    Solicitation

    Due August 21, 2026 at 1:00 PM EDT. SAM.gov, notice de3b9858cdb149658e075b39c6795126

    1 revisions on SAM
    • August 7, 2026: publish, solicitation

Points of contact