Solicitation, total small business set-aside
Laser-Safe Enclosure
N0018926QB093
Department of the Navy, NAVSUP FLT Log CTR Norfolk. Prefabricated Metal Building and Component Manufacturing.
Response deadline
July 13, 2026 at 12:00 PM EDT
Closed 111 days ago. Posted July 2, 2026. Scheduled to archive July 14, 2026.
Get the next one like this from Department of the Navy by email, the day it is posted.Find my opportunities
This one closed in 2026
7 like it are open now in prefabricated metal building and component manufacturing
- ROOF TARPS
Defense Logistics Agency, DLA Maritime - Puget Sound
Combined synopsis and solicitationSmall businessNAICS 332311Anywhere in the USSPMYM227Q1113Closes tomorrowNov 2 - ID-KOOSKIA NFH-FORMALIN STORAGE BLDG
Departmental Offices, FWS Contracting Activity
Combined synopsis and solicitationSmall businessNAICS 332311Location not published140FF027Q0032Closes in 4 daysNov 5 - Arkabutla Lake Water Plant Rehab and Pre-fabricated Metal Building Installation
Department of the Army, W07V Endist Vicksburg
Combined synopsis and solicitationSmall businessNAICS 332311Anywhere in the USW912EE27QA002Closes in 5 daysNov 6
All 7 open in prefabricated metal building and component manufacturing
Description
As published on SAM.gov.
The NAMRU-SA, DEHE Department requires one (1) laser-safe enclosure rated to withstand direct and scattered laser radiation from a 10kW laser, ensuring that radiation levels outside the enclosure remain below the Maximum Permissible Exposure (MPE) limits as defined by relevant safety standards.
Specifications:
Laser Radiation Protection: To withstand radiation levels of a 10kW laser, the enclosure must utilize material explicitly rated to
withstand reflections from a laser powered at 10,000 W/cm, 1060-1070 nm for 10 seconds with a 1 mm beam diameter. This
specific threshold provides the necessary barrier against direct or reflected beams from a 10kW source.
Safety Interlock System: The enclosure must feature a fully integrated safety interlock system connected to the access door(s).
The interlock must automatically disable the laser system's operation immediately upon an access door being opened.
Physical Dimensions: The enclosure must provide minimum internal dimensions of 12 feet in length, 12 feet in width, and 10
feet in height (12' L x 12' W x 10' H) to accommodate the laser system, personnel, and associated equipment.
Build Design: The enclosure must contain roof and lighting kit.
Access Control: The access door mechanism must be designed to restrict entry to authorized and trained personnel only.
Environmental Control: The enclosure must be designed to minimize the accumulation of airborne dust and particulates on
internal optics and equipment.
Standards & Compliance: The enclosure must be delivered with all required safety features to meet or exceed ANSI Z136.1
("Safe Use of Lasers") standards. This includes, but is not limited to, appropriate warning labels, signage, and emergency
procedure information affixed to the enclosure.
Warranty Terms: Standard 12-month warranty against defects in material and workmanship.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- N0018926QB093.pdf1.8 MB, July 2, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 2, 2026
Solicitation
Due July 13, 2026 at 12:00 PM EDT. SAM.gov, notice 073285fe15d1439e822b4b3d1cc013c6
1 revisions on SAM
- July 2, 2026: publish, solicitation
Points of contact
- Kimberly Mrasekkimberly.m.mrasek.civ@us.navy.mil