Solicitation, total small business set-aside
Military Housing Office Inspection Kits
MHO194
Department of the Air Force, FA8903 772 Ess PK. Other Measuring and Controlling Device Manufacturing.
Response deadline
July 6, 2026 at 3:00 PM EDT
Closed 72 days ago. Posted June 30, 2026, first published June 26, 2026. Scheduled to archive July 21, 2026.
Description
As published on SAM.gov.
Amended paragraph #3 & #7 on 30 June 2026 (see attachments) 1. Binoculars; Quantity = 194 Make/Model: Fujinon 10x50, Steiner 10x50 Military Marine, or equivalent Specifications for "Steinger Military Marine 10x50" (or equal) products:
Magnification:
10x Objective Lens Diameter: No less than 50mm Field of View: No less than 327 ft at 1000 yds Focus:
Auto Focus System Optics: Fully coated high contrast optics Close Focus: No more than 75 ft IP Distance:
56-74mm Diopter Range: +/- 5 pdt Luminosity: No less than 25 Durability: Rubber Armoring (Rugged), Waterproof, Housing designed for minimum 8G impact Includes:
Objective Covers, Carrying Case, High Contrast, Neck Strap 2. Borescopes; Quantity = 194 Make/Model: Teslong TD-500, Kentfaith Dual -Lens Articulating Borescope, or equivalent Specifications for "Teslong TD-500" (or equal) products:
Camera Pixels: 1.0 Megapixel minimum Probe: 2 Way Articulating Probe, 210 deg articulation, diameter no greater than 8.55 mm Field of View: 60 degrees minimum Display: 5 inch minimum, with a screen resolution of at least 854x480 pixels Probe Length: Between 4 to 8 feet Image Resolution: 1920x1080 pixel Durability: IP 67 waterproof 3. Combination IR and Probe Thermometers; Quantity = 194 Thermoworks IRT-2 with standard type T straight probe or equal.
Minimum IR Range -40 to 250 deg F Minimum IR accuracy +/- 1.8 deg F from 32 deg to 149 deg F Thermocoupler (probe) specifications Minimum Range 32 deg F to 149 deg F minimum Minimum Accuracy +/- 0.9 deg F from 32 deg F to 149 deg F Must include a type T straight Penetration Probe, standard tip 4. Combustible Gas Meters / Combustible Gas Leak Detection; Quantity = 194 Make/Model: TPI 775, BPI Basics Kit, Gas Leak Detector CO Monitor, or equivalent Specifications for "TPI 775 " (or equal) products:
Carbon Monoxide Detection:
Resolution: 1ppm or lower Range: 0-2,000ppm or larger range Accuracy: +/- 5ppm or 5% of reading (whichever is greater) or better Combustible Gas Leak Detection:
Resolution: <50ppm Range: 0 – 50,000 ppm Accuracy: +/- 10% Detectable Gases: Must detect Natural Gas and Propane Alarms: Audible alarm for leaks, adjustable gas upper alarm threshold limit for alarm to permit gas leak isolation 5. GFCI Testers; Quantity = 194 Make/Model: Ideal 61-502 or equivalent Specifications for "Ideal 61-502 120V AC Receptacle Tester" (or equal) product:
Certification: UL 1436 and CSA C22.2 no 160 listed Detection Capabilities: Detects open ground, reverse polarity, open hot, open neutral, hot and ground reversed, and hot on neutral with hot open.
Functionality: Push to Test function to test operation of GFCI receptacles. 6. Water Pressure Testers; Quantity = 194 Make/Model: Watts 3/4 Inch Plastic Water Pressure Test Guage, or equivalent Specifications for "WATTS ¾ inch Plastic Water Pressure Test Gauge" (or equal)
Connection: ¾ inch FIP connection Accuracy: ASME, type B Working Pressure: 0-140 psi Max Pressure: 200 psi 7. Thermal Imagers; Quantity = 194 Thermal imager minmum specifications: Thermal resolution: 160 x 120 pixels or greater Thermal sensitivity: < 150 mK or lower Field of View: 57 deg x 44 deg or higher Temperature range: 32 deg F to 170 deg F or greater Image modes: Thermal, Visual and mode that embosses visual details into thermal images Digital camera minimum specifications 2 MP or greater 70deg x 55 deg minimum field of view 320 x 240 pixel minimal color display Built in Moisture Detection both pinless and external pin probes (in lieu of this the vender can provide a separate moisture meter) Pinless depth to 0.75 inches Pin probes provided for pin operation Range 7% to 30% or greater with accuracy to +/- 1.5% Range 30% to 100% with reference only accuracy Built in Air Temperature, Relative Humidity and Dew Point sensors (in lieu of this the vender can provide a separate meter to measure temperature, relative humidity and dew point) Temperature range: 32 deg F to 120 deg F or greater with minimum accuracy of +/- 1.1 deg F or better Relative Humidity range: 10%-90% or greater/ accuracy +/- 2.5% or better Dew Point -20 deg F to 120 Deg F or greater with accuracy of +/- 1.8 Deg F or better
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Gregorio Armandgregorio.armand@us.af.mil2103633758
- Latonya McGaskeyLatonya.McGaskey@us.af.mil380-458-6193
Also open from this buyer
- Book and Audiobook Point PlanCombined synopsis and solicitationNAICS 516210TexasFA890326A068824Closes todaySep 16
- Remote Video Game KitsSolicitationNAICS 339930TexasFA890326A067696001Closes in 5 daysSep 21
- Request for Lease Proposal (RFLP) Enhanced Use Lease Project Nellis Air Force Base, NV. Amendment 2SolicitationNAICS 531120NevadaAFCEC-26-R-0007Closes in 8 daysSep 24
- REQUEST FOR INFORMATION MINERAL PROCESSING LEASING OPPORTUNITIESSources soughtNAICS 53119IdahoAFCEC-26-R-0011Closes in 23 daysOct 9
- NEW - Air Force Installation and Mission Support Center (AFIMSC) Streamlining Procurement for Effective Execution & Delivery (SPEED) Commercial Solutions Opening (CSO)Combined synopsis and solicitationNAICS 541FA890326SC001Closes in 1443 daysAug 29, 2030