Presolicitation, service-disabled veteran-owned small business set-aside
Room Renovation, Moore Air Base, TX
JR1155383
Animal and Plant Health Inspection Service, MRPBS Minneapolis MN. Commercial and Institutional Building Construction.
Status
Presolicitation
Posted July 11, 2025. Scheduled to archive September 15, 2025.
Get the next one like this from Animal and Plant Health Inspection Service by email, the day it is posted.Find my opportunities
This one is not taking offers
184 like it are open now in commercial and institutional building construction
- FMC Fort Worth - Upgrade Pharmacy Cleanroom
Federal Prison System / Bureau of Prisons, Fao
Sources soughtNAICS 236220Fort Worth, TX15B50926PR000491Closes in 2 daysNov 3 - RFI: Fort Wolters H Barracks
Department of the Army, W076 Endist FT Worth
Sources soughtNAICS 236220Mineral Wells, TXPANSWD26P0000032201Closes in 3 daysNov 4 - Unaccompanied Enlisted Personnel Housing (UEPH) Barracks# 103
Department of the Army, W076 Endist FT Worth
Sources soughtNAICS 236220Fort Hood, TXW9126G27RA009Closes in 10 daysNov 11
All 184 open in commercial and institutional building construction
Description
As published on SAM.gov.
USDA’s Animal and Plant Health Inspection Service has a construction requirement to renovate a room in building 6418 at Moore Air Base in Edinburg, Texas.
Background: Building 6418 at Moore Air Base is a Mexican Fruit Fly Rearing Facility. The Mexican Fruit Fly Program is charged with the eradication of Mexican Fruit Flies from the Lower Rio Grande Valley in Texas and the northern municipalities of Tamaulipas, Mexico. Building 6418’s Colony Egg Bubbling Room is where fly eggs are cleaned and incubated. The equipment and furniture in the room is corroded beyond repair, along with the floors, which are dilapidated due to high traffic, corrosive chemical washout, and foundation settling.
Demolition: Curtin off hallways to the bottom side of roof to for dust control (utilize usage of exhaust fans) cover existing floor drain Remove all instruments and equipment from counter tops Remove all suspended ceiling Remove metal door and frame Remove base cabinets and hung cabinets Relocate stainless-steel table and chemical tanks Furnish and Install: Repair CMU walls and paint walls Epoxy coat concrete floor Install new anti-corrosion material base cabinets with sink and counter tops Install new anti-corrosion material hung cabinets Install new touchless fixtures Install stainless steel table and chemical tanks Re-install suspended ceiling This project will be set aside for service-disabled veteran-owned small business firms only.
The NAICS code is 236220 – Commercial and Institutional Building Construction, with a small business size standard of $45 million. The estimated magnitude of the project is between $100,000 and $250,000. The project will be set aside for small business concerns only. The solicitation will be posted on or about July 24, 2025. It is the responsibility of interested parties to monitor this site for the solicitation and amendments, if any. Questions concerning this synopsis should be directed to Jim Roloff, contracting officer, at james.g.roloff@usda.gov.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 11, 2025
Presolicitation
SAM.gov, notice ca5ad3d3fae34f30b11225a2dd249395
Points of contact
- Jim Roloffjames.g.roloff@usda.gov6125907603