Skip to content
  • 6,813 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell Abierto what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and Abierto tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans
AbiertoGet started

Presolicitation

Pipette Calibration Systems

75D30126Q79012

Centers for Disease Control and Prevention, CDC Office of Acquisition Services. Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals.

Awarded

Sartorius Corporation

$172,891.25 obligated so far on USAspending

Get the next one like this from Centers for Disease Control and Prevention by email, the day it is posted.Find my opportunities

This one was awarded in 2026

31 like it are open now in instrument manufacturing for measuring and testing electricity and electrical signals

  • GA-VGMS-33528

    Department of the Air Force, FA2263 AFLCMC Romk Afmetcal

    Sources soughtNAICS 334515Georgia27M-638A-VA
    Closes in 16 daysNov 17
  • TRANSDUCER,MOTIONAL

    Defense Logistics Agency, Sprmm1 DLA Mechanicsburg

    SolicitationNAICS 334515Anywhere in the USSPRMM126QHA87
    Closes tomorrowNov 2
  • Keysight Network Analyzer

    Defense Microelectronics Activity, Defense Microelectronics Activity

    Combined synopsis and solicitationNAICS 334515Anywhere in the USHQ072727QMH02
    Closes tomorrowNov 2

All 31 open in instrument manufacturing for measuring and testing electricity and electrical signals

Description

As published on SAM.gov.

The program is requesting purchase of one SpeedCal Mobile multichannel pipette calibration system for the gravimetric testing of multichannel pipettes according to DIN EN ISO 8655 and one Cubis II single channel pipette calibration system with moisture trap, automated draft shield and proximity sensor. These items are manufactured by Sartorius Corporation.

In order for NCIRD to achieve their mission, laboratory equipment must be compliant with either the Clinical Laboratory Improvement Amendments (CLIA) regulations or with the International Standards Organization (ISO) requirements. These regulations and standards require calibration and maintenance of laboratory equipment, including pipettes, to ensure the accuracy and reliability of test results and uphold quality control standards in clinical labs. This purchase is for two new calibration units that will be used for this purpose.
There are two gold-standard approaches to checking the accuracy of a pipette’s calibration—photometric, where the absorbance of a dye is measured to determine the volume actually delivered; and gravimetric, where distilled water is weighed to determine how much volume was delivered. The photometric method requires costly consumables in addition to equipment acquisition costs. In contrast, the gravimetric method only requires distilled water, and therefore the main associated cost is the equipment acquisition cost.

When calibrating a large number of pipettes using the gravimetric method, it is optimal to use a balance designed for the purpose of pipette calibrations. This specially-designed balance integrates with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors from the redundancy of a repetitive task. The number of manufacturers of such systems is very limited.

The Sartorius Cubis® II MPS 116S single-channel pipette calibration balance and SpeedCal Mobile 12 multichannel pipette calibration system are specially designed for pipette calibration and integrate with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors.
Web API – Both Sartorius systems use a web API to transfer data. A web API is a standardized way for different systems to talk to each other, regardless of who made them. In practical terms, this means data from the pipette calibration system can be sent directly into other lab systems without staff having to manually record, transform, or transfer results. Instead of relying on proprietary connections that only work within a single vendor’s ecosystem, a web API uses open, widely accepted communication methods—similar to how websites interact over the internet—allowing systems from different manufacturers to work together seamlessly. This saves staff time, reduces transcription errors, improves data reliability, and enables integration across systems.
Multichannel calibration system with 12 independent load cells - Weighing distilled water is how pipette calibrations are performed gravimetrically. A load cell is the portion of a balance that weighs the water. Twelve independent load cells means the system can measure weights simultaneously (i.e. in parallel). This improves speed and reduces the impact of environmental changes and other sources of drift. The Sartorius system meets this requirement. Other systems have a single load cell and their systems can only measure the weights sequentially. This translates to both longer wait times while the system is measuring, and an increased impact of environmental changes, like the evaporation of water, which has a negative effect on pipette calibrations.
Mobile-ready single channel and multichannel pipette calibration systems - The NCIRD team providing pipette calibration service does not have dedicated laboratory space at the Roybal campus. Instead, pipette calibrations are performed in the space owned by the requesting lab. Therefore the systems used must be designed for mobility. 
An equipment manufacturer with an established U.S presence and responsive technical support -
Both the single channel and multichannel pipette calibration systems will be used to calibrate pipettes for NCIRD labs. When a pipette’s calibration expires, it cannot be used to perform laboratory work. Timely recalibration is necessary to prevent disruptions to laboratory testing. If the system used to perform calibration is out of service, then pipettes cannot be recalibrated in a timely manner. A vendor with responsive, U.S.-based field service technicians is essential for continuity of NCIRD laboratory operations.
 

The technical requirements necessitating sole source for this procurement are as follows:

1. API/Web Integration

2. Mobility

3. Multichannel calibration system with 12 independent load cells

4. Established US customer support

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
Z867UMB3LJJ1
CAGE
0DNR2
Vendor location
Bohemia, NY
Contract
75D30126P21137, purchase order
Obligated
$172,891.25
Actions
1 between August 11, 2026 and August 11, 2026
Competition
Not Competed Under SAP, 1 offer received
Set-aside reported
No Set Aside Used.
Described as
Pipette Calibration Systems Eo 14398
Match
solicitation number 75D30126Q79012 equals the FPDS solicitation identifier; same awarding office 75D301 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 22, 2026

    Presolicitation

    Due August 7, 2026 at 8:00 AM EDT. SAM.gov, notice 8ec28bdcc1b24654a386c3415fc7798e

    1 revisions on SAM
    • July 22, 2026: publish, presolicitation

Points of contact