Special notice, total small business set-aside
USCGC MUNRO GAS TURBINE BLEED AIR HOSE INSULATION
70Z8526Q025799
US Coast Guard, SFLC Procurement Branch 2. Ship Building and Repairing.
Response deadline
July 1, 2026 at 11:00 AM EDT
Closed 77 days ago. Posted June 27, 2026, first published June 26, 2026. Scheduled to archive July 16, 2026.
Description
As published on SAM.gov.
Mofification 1 to this solicitation was to correct the POP in the attached SOW.
Correct: period of performance for this contract shall be between 01JUL2026 & 15JUL26. STATEMENT OF WORK (SOW) FOR GAS TURBINE BLEED AIR HOSE INSULATION CGC MUNRO has a need to replace insulation covers on the Gas Turbine Bleed Air Hose. The ship’s Main Gas Turbine is currently non-operational and has an immediate need for new insulation materials as outlined in this Statement of Work (SOW). 1.0 GENERAL Background USCGC MUNRO inadvertently soaked the insulation surrounding GTBA-HOSE-1 with an oily water.
The hose is for the anti-icing bleed air system located underneath the Main Gas Turbine Module. Inundated insulation causes smoking when the Gas Turbine is operated in external temperatures above 40 degrees; preventing operation of the turbine. Scope The scope of this contract is defined by the efforts and tools required to support USCGC MUNRO (WMSL 755). The Contractor shall manufacture new removeable insulation covers to the dimensions and specs provided.
OBJECTIVE The goal is to return CGC MUNRO to Fully Mission Capable (FMC) status. This is a critical need and shall be completed as soon as possible, in order to minimize negative operational impact to MUNRO’s Operational Commander.
APPLICABLE DOCUMENTS Reference Documents The following documents may be helpful to the Contractor in performing the work described in this document: Coast Guard Drawing (CGDWG) 750-WMSL-508-001, Rev C, JUNE 2009, Piping And Machinery Insulation Schedule And L/M (ASC508001) Coast Guard Drawing (CGDWG) 750-WMSL-259_023, Rev C, OCTOBER 2014, Bleed Air Piping & Joint Ident (P1 System) Unit 2210 SPECIFIC REQUIREMENTS/TASKS Existing insulation cover dimensions are as follows:
Length Width Thickness Inner Layer 34” 22” 2” Outer Layer 45” 28” 2” Fabrication of reusable covers shall comply with ASTM F683-99, PARA 8, PAGE 8. For temperature 450 degrees Fahrenheit and over the covers shall be made up of layers of glass fiber felt to make up the required thickness. The inside and ends shall be wrapped with knitted wire mesh or fibrous glass cloth “wire-inserted”. The outside shall be covered with fibrous glass cloth.
Covers shall be sewn and quilted with thread to provide a uniform thickness, strength and ridigity. 3.0 OTHER APPLICABLE CONDITIONS 3.1 Period of Performance - The period of performance for this contract shall be between 01JUL2026 & 15JUL26. 3.2 PLACE OF PERFORMANCE The primary place of performance will be at the contractor’s facility.
After completion, contractor will deliver to USCG Base Alameda, 1 Eagle Rd, Alameda CA 94501 4.0 CONTRACTOR FURNISHED PROPERTY The Contractor shall furnish all materials, equipment, and services necessary to fulfill the requirements of this contract.
5.0 Points of Contact USCG-SFLC-LREPL, Asset Manager: LTJG Justin Waters, 206-827-5766, justin.l.waters@uscg.mil 6.0 Imagery Outer Lagging Inner Lagging
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 26, 2026
Special notice
Due July 1, 2026 at 11:00 AM EDT. SAM.gov, notice 0219e6f1ac604287a82038c1cff0d6d9
June 26, 2026
Special notice
Due July 1, 2026 at 11:00 AM EDT. SAM.gov, notice bdc5bda4d5d843a8a06687da23de130b
June 27, 2026
Special notice
Due July 1, 2026 at 11:00 AM EDT. SAM.gov, notice c4badd92b7744228b29cdaecdee64dc8
Points of contact
- McTague, SeanSean.P.McTague@uscg.mil15716143888
- ULISES BALMACEDAUlises.O.Balmaceda@uscg.mil2068200307
Also open from this buyer
- CGC HEALY SPIRAX SARCO STEAM TRAPCombined synopsis and solicitationSmall businessNAICS 332911Washington70Z08526Q0027750Closes todaySep 16
- CGC OAK WATER TIGHT DOORS, HATCHES, SCUTTLES RENEWALCombined synopsis and solicitationSmall businessNAICS 332321Rhode Island70Z08526Q0027652Closes in 2 daysSep 18
- USCGC POLAR STAR MOBILE DTECombined synopsis and solicitationSmall businessNAICS 424720Washington14501_MOBILE_DTE_FY26Closes in 3 daysSep 19
- Heater ElectricSolicitationSmall businessNAICS 333414Maryland70Z08526Q30113B00Closes in 3 daysSep 19
- USCGC Stratton Shaft Alignment and Bearing Reaction CheckCombined synopsis and solicitationSmall businessNAICS 811310California70Z08526Q0026058Closes in 5 daysSep 21