Combined synopsis and solicitation, total small business set-aside

Katmai Bay Fan Coil

70Z085PR240006849

US Coast Guard, SFLC Procurement Branch 2. Ship Building and Repairing.

Response deadline

September 20, 2024 at 11:00 AM EDT

Closed 727 days ago. Posted September 13, 2024, first published August 28, 2024. Scheduled to archive September 20, 2024.

Description

As published on SAM.gov.

This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z085PR240006849 and is issued as a request for quotations (RFQ). This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued.

This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a total small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5.

All responses from interested vendors must be received on/before 0800am Pacific Time, Sep 20th, 2024, and will be reviewed by the Government. The United States Coast Guard Surface Force Logistics Center has a requirement for the following:

The CTR shall provide Boiler System/ Duct Coil and Electric Heater 1. SCOPE 1.1 Intent. This work item describes the requirements for the Contractor to replace Duct Coil Pre Heater and Electrical Heater in the Fan Room. Correct leaking pipe fitting in Aux 1, Bosn hole, and pressure test system. Work will be on a WTGB 140 located at 337 East Water Street Sault Sainte Marie, MI 49783. POC Jayson Pol, 305-746-4292 1.2 Government-furnished property. Duct Coil Pre-heater P/N 3W11-18-5605F, Qty 1, Unit has on hand.

Vent Duct Heater VDH18X16-2(412.5-3)-12, Qty 1, Order via AM pending delivery of part. DOWFROST HD 50% - 55 gl Drum, Qty 2, Quote provided. 2. REFERENCES Coast Guard Drawings 140-WTGB-514-011 HVAC Electrical Vent System Schematic, Block Wiring Diagram, & Arrangement Details.

140-WTGB-514-017 Post Slep Hot Water Heating System Diagram (SRD) Coast Guard Publications Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2014, General Requirements Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 0740), 2014, Requirements for Wedling and Allied Process Technicial Publication 3938, Hull Mechanical & Electrical, Ray Burner (Boiler) Other References None 3. REQUIREMENTS 3.1 General. 3.1.1 CIR.

The Contractor shall submit a CIR for the inspections listed in the following paragraph(s): Boiler System 3.1.2 Tech Rep. Certified welder for repairs. 3.1.3 Protective measures - general. The Contractor shall furnish and install all protective coverings to seal off and protect all non-affected vessel's components, equipment, and spaces near the work area against contamination during the performance of work.

Upon completion of work, the Contractor shall remove all installed protective measures, inspect for the presence of contamination, and return all contaminated equipment, components, and spaces to original condition of cleanliness. 3.1.4 Interferences. The Contractor shall be aware that interferences in way of work include, but are not limited to the following:

Piping, foundations, insulation and electrical wiring.

3.2 Work: The Contractor shall remove isolate Duct Coil Pre-Heater drain DOWFROST HD 50% sweet of piping from damage coil and install new and pressure test weld. Remove and install new Electrical Heater and OP test. Isolate pipes in Aux 1 and Bosn Hole to inspect unions and replace O-rings, reseal union to repair leaks. Remove and dispose of up to 120 gallons of DOWFROST HD 50% in accordance with all local, state, and federal laws.

Upon renewal and installing water sire system contractor will conduct an entire system pressure test and replenish with new DOWFROST HD. System will be placed in normal operation and conduct operational test. 3.4 Touch-up preservation. Renew insulation removed for coils and touch up any paint. 4. NOTES 4.1 Marine Chemist certification will be required prior to any hot work / use of open flame. 4.2 Contractor provides Fire Watch. g. All consumables to include but not limited to:

Nitrogen, silver, flux, oxygen, acetylene, rags shall be provided by contractor.

5. POP 01-15OCT2024 6. Unit POC: CWO Jayson Pol 305-746-4292 7.Work to be completed Mon-fri 0730-1800 unless authorized by EO to alter.

Delivery Address:

Address: USCGC Katmai Bay WTGB101 337 E Water St Sault Sainte Marie MI 49783 Questions and quotes shall be emailed to Jeramyah.W.George@uscg.mil and Nathan.S.Damon@uscg.mil. Contractors are responsible for verifying receipt of quotes. INTERESTED VENDORS PLEASE SIGN AN OFFICIAL QUOTE WITH A SAM.GOV REGISTERED DUNS NUMBER AND EMAIL TOJeramyah.W.George@uscg.mil and Nathan.S.Damon@uscg.mil.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. August 28, 2024

    Combined synopsis and solicitation

    Due September 12, 2024 at 11:00 AM EDT. SAM.gov, notice 0f8aeb3d184d4357a7350afb0116eb4a

  2. September 13, 2024

    Combined synopsis and solicitation

    Due September 20, 2024 at 11:00 AM EDT. SAM.gov, notice 29b9feb3f5bb440bbd4bfda90dbd94df

  3. September 13, 2024

    Combined synopsis and solicitation

    Due September 20, 2024 at 11:00 AM EDT. SAM.gov, notice 93bfaaa9b5164e4ca36e0986bbb79bff

Points of contact