Award notice, service-disabled veteran-owned small business set-aside, first published as presolicitation
Project 575-23-107 | Expand Electrical Capability | Design
36C25925R0113
Department of Veterans Affairs, Network Contract Office 19. Engineering Services.
Awarded
$769,409.00 on the award notice, July 16, 2026, contract 36C25926C0059
Description
As published on SAM.gov.
SCOPE OF WORK: This contract will provide designs for expanding the electrical capacity of the Grand Junction VA Medical Center. The A-E is to provide design services to expand the electrical capacity of the Grand Junction VA Medical Center (2121 North Ave, Grand Junction, COÂ 81501). The contractor shall design the following:
Statement of Work: The Grand Junction VA Medical Center campus has 22 buildings, with 321,557 gross square feet of space. To expand services, the VA requires additional electrical power on the north and east sides of the campus. The northern electrical room remodel will support future expansions while the newly created eastern electrical room will support temporary facilities that provide workspaces for displaced employees.
In the past, temporary spaces have been modular in nature and could be tents, trailers or other types of temporary facilities. Most work will be conducted indoors, however, Grand Junction, CO has a semi-arid climate, with hot summers and generally mild winters. During the summer months temperatures typically reach into the 90s Fahrenheit during the day, while evenings tend to remain comfortable and cool. Winters are usually mild, but snow does occur, and temperatures can cool down to freezing averages.
Spring and fall tend to be transitional seasons with moderate temperatures. The area receives around ten (10) inches of precipitation per year with most of it falling from April through August. Specific project tasks: Remodel and add on to 1634-1 (433 SF) / 1635-1 (433 SF) to ensure adequate electrical utilities exist to support the north portion of the WCHCS on the Grand Junction, CO campus. This will include expanding the rooms by 800 SF to the west.
This additional space will allow the hospital to add switchboards and panels when needed and enclose an Automatic Transfer Switch (ATS). Add a new electrical room to ensure adequate electrical utilities are in place on the eastern side of the WCHCS on the Grand Junction, CO campus. This will provide electrical capacity from location 1 on the western side of the WCHCS to location 2 (see attachment A) on the eastern side.
The minimum power requirements are three-phase, 208V, 800A and include normal, critical, life safety and emergency power circuits. This electrical run will terminate in a new conditioned electrical space at location 2 after passing through necessary electrical step-down equipment at site 3. Any future projects that have temporary facilities will be designed to be compatible with 208V and use no more than 80% of the amperage available per branch circuit.
These facilities will be expected to run power from their location to the new electrical room distribution point designed at location 2. All aspects of the design must adhere to the NEC Design manuals posted on the VA technical information library at the following sites: http://www.cfm.va.gov/til/ and https://vatilms.va.gov/vatilms/catalog. All electrical, architectural, and mechanical work for these systems will be designed by the A-E.
The installation must, at a minimum, be in accordance with all applicable codes indicated in the Department of Veterans Affairs (VA) Design Manuals and VA Publications (Master Construction Specifications, Construction Standards, National Fire Protection Association (NFPA), Underwriters Laboratory, International Building Code IBC 2003, NFPA and National Electric Code (NEC), building codes and standards, and VA Information Security Handbook 6500.6, etc.).
DESIGN CRITERIA: As part of the design the following list needs to be considered: All electrical work will be terminated by the contractor. The design must be clear who and what is supplied for the termination equipment. Any penetration through any fire barriers whether a floor or wall will be done in this contract to meet VA standards and National Fire Protection Association (NFPA). The contractor shall obtain permits issued by the facility before any penetration shall occur.
The installed system and its components shall be tested and commissioned. This will be included in the design and construction documents. Implement new technologies in electrical systems to improve and facilitate energy usage reductions. The system will be compatible with the existing control systems on station. All finishes will be coordinated with the VA interior designer and called out in a finish schedule. All testing and balancing parameters will be provided by the A-E.
Design documents that show the red lines will be submitted by the contractor to the A-E, put into the AutoCAD drawings and submitted within 30 days of the completion of the construction project. According to VA standards as outlined in the VA Specifications Technical Library. All existing utilities which are designed to be relocated or modified shall have directions to the contractor on the new location and modifications.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Citrine LLC
- UEI
- JKPGTKHSKRP4
- CAGE
- 7PL41
- Vendor location
- Lakewood, CO
- Contract
- 36C25926C0059, definitive contract
- Obligated
- $574,773.00, potential $769,409
- Actions
- 1 between July 16, 2026 and July 16, 2026
- Competition
- Full and Open Competition After Exclusion of Sources, 1 offer received
- Set-aside reported
- Service Disabled Veteran Owned Small Business SET-ASIDE
- Described as
- AE Design to Expand the Electrical Capacity for the Grand Junction VA Medical Center
- Match
- award number 36C25926C0059 equals the contract number; same awarding office 36C259 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
September 12, 2025
Presolicitation
Due October 13, 2025 at 12:00 PM EDT. SAM.gov, notice 115019a8a65f4f57b3fa2c563933b343
September 26, 2025
Presolicitation
Due October 13, 2025 at 12:00 PM EDT. SAM.gov, notice 8e31b4e7cd80453da2b6038ceefe7483
October 7, 2025
Presolicitation
Due October 23, 2025 at 12:00 PM EDT. SAM.gov, notice b972bd90b6724951b7fa417fa9b1b24a
July 17, 2026
Award notice
Awarded to Citrine LLC Lakewood 80215 for $769,409. SAM.gov, notice 33b62408f6c345ed976e3965fa194191
July 17, 2026
Award notice
Awarded to Citrine LLC Lakewood 80215 for $769,409. SAM.gov, notice 9c6cb234489c46c980f52d351258742d
Points of contact
- Mark Holland, Contract SpecialistMark.Holland@VA.gov303-712-5828
Also open from this buyer
- EksoNR Exoskeleton – Gait Training DeviceCombined synopsis and solicitationSmall businessNAICS 334510Oklahoma36C25926Q0851Closes tomorrowSep 17
- Bulk Oxygen and Tank Rental for Oklahoma City VA Health Care System Base Plus 4 Option YearsCombined synopsis and solicitationSDVOSBNAICS 325120Oklahoma36C25926Q0814Closes tomorrowSep 17
- 635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)SolicitationSDVOSBNAICS 236220Oklahoma36C25926R0082_1Closes tomorrowSep 17
- CCTV MOBILE CAMERA TRAILERS - SHERIDAN VAMCCombined synopsis and solicitationSmall businessNAICS 561621Colorado36C25926Q0812Closes tomorrowSep 17
- Surgery Lumber Retractor Instruments – Domestic End ProductsCombined synopsis and solicitationSmall businessNAICS 339112Oklahoma36C25926Q0861Closes tomorrowSep 17