Award notice, total small business set-aside, first published as combined synopsis and solicitation
Boiler Safety Device Testing/Inspection Services
36C25626Q0276
Department of Veterans Affairs, 256-Network Contract Office 16. Plumbing, Heating, and Air-Conditioning Contractors.
Awarded
$29,000.00 obligated so far on USAspending
Description
As published on SAM.gov with the combined synopsis and solicitation of January 27, 2026.
AMENDMENT 0004- The purpose of this amendment is to provide responses to vendors' questions. The following responses are provided: (SEE ATTACHMENT)
Question 1: Place of Performance (pages 2 & 3): Please confirm that there are two separate locations where services are required:
Eugene J. Towbin Healthcare Center: 2200 West Fort Roots Drive North Little Rock, AR 72114. John L. McClellan Memorial Veterans Hospital: 4300 W 7th St. Little Rock.
AR 72205. Answer 1: Services are required at the two separate locations listed above.
Question 2:
Internal Boiler Inspection Requirement: The PWS document does not specify whether annual internal boiler inspections are required. Please confirm if this contract includes internal inspections performed by a National Board (NB) / ASME-certified boiler inspector, or if the scope is limited strictly to safety device testing If internal inspections are required, please confirm whether: VA will open, drain, clean, and prepare the boilers Any state of Arkansas jurisdictional inspection coordination is required under this contract Answer 2: Safety device testing only.
Question 3:
Non-Destructive Testing (NDT): The PWS document does not specify any non-destructive testing (NDT) requirements for boilers, deaerators, or condensate tanks. Please confirm whether any NDT services are included or excluded from this contract.
Answer 3: Safety device testing only.
Question 4: VHA Boiler Plant Safety Device Testing Manual – Edition Conflict: The PWS references two (2) editions: Page 12 and Section 1.e/f reference the Fifth Edition. Section 1.b.v references the Seventh Edition. Please confirm the official edition of the VHA Boiler Plant Safety Device Testing Manual that the contractor is required to follow.
Answer 4: The official edition of the VHA Boiler Plant Safety Device Testing Manual that the contractor is required to follow is the most current, 7th Edition.
Question 5:
OEM Authorization: Please confirm whether OEM authorization letters are required for: Each boiler manufacturer (Superior and Johnston) Burner management systems and safety controls (if different OEMs apply) Also, please confirm whether subcontractors performing testing must also hold OEM authorization, or if authorization held by the prime contractor is sufficient.
Answer 5: OEM authorization letters are not required but will be accepted. However, contractor shall provide proof of certification attesting that all gauging and measurement equipment used has been currently calibrated either according to the manufacturer’s specifications or a standard traceable to the National Bureau of Standards. Combustion Analysis and Safety Device Testing personnel shall be qualified for boiler plant burner, control and instrumentation testing.
Qualifications include completing at least a one-year trade school and five years of successful experience in this field. The experience shall be largely with institutional and industrial boiler plants similar in design to the VAMC plants.
Question 6:
Repairs and Out-of-Scope Work: The PWS document indicates that adjustment and calibration of safety devices. Please clarify: Are minor adjustments and calibrations included in the base scope? : Are repairs, parts replacement, or corrective maintenance excluded and must be quoted separately? Should the contractor provide written repair recommendations only, or Is the contractor expected to submit repair quotes under this contract?
6. Answer 6: a. Minor adjustments and calibrations: Yes if adjustments can be made to bring device into compliance. If necessary, make adjustments to the fuel flow and combustion air controllers, control valves and dampers to obtain the required performance. Repairs, parts replacement, or corrective maintenance are excluded. Contractor shall immediately inform COR of any recommended repairs, modifications, or safety related problems. Contractor can quote separately if desired. Yes, contractor shall provide written repair recommendations only.
Question 7: Emergency Call-Out Services The PWS document does not reference emergencies, after-hours, or unscheduled call-out services related to boiler, burner, or safety device failures discovered during or outside the scheduled semi-annual testing. Please confirm whether emergency response or on-call services are:
Included within the scope of this contract, or Excluded and to be handled under a separate contract or task order. If emergency services are included, please clarify: Required response time (e.g., 2-hour, 4-hour, same-day) Whether after-hours, weekend, or holiday work may be required How these services are to be authorized and charged. There is not a CLIN number added to the cost schedule.
Answer 7: Emergency responses or on-call services are not included in this contract. End
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Atz Solution LLC
- UEI
- EDYBXLTSKGG5
- CAGE
- 9LYF8
- Vendor location
- Charlotte, NC
- Contract
- 36C25626C0030, definitive contract
- Obligated
- $29,000.00, potential $165,000
- Actions
- 2 between March 31, 2026 and May 27, 2026
- Competition
- Competed Under SAP, 14 offers received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- Boiler Safety Device Testing/Inspection Service
- Match
- award number 36C25626C0030 equals the contract number; same awarding office 36C256 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
January 2, 2026
Combined synopsis and solicitation, originally presolicitation
Due January 23, 2026 at 9:00 AM EST. SAM.gov, notice 454616fba4384babb88de6305160de4c
January 13, 2026
Combined synopsis and solicitation
Due January 27, 2026 at 9:00 AM EST. SAM.gov, notice 8493563f5907460e9d1e45cecfa4fa40
January 15, 2026
Combined synopsis and solicitation
Due January 27, 2026 at 9:00 AM EST. SAM.gov, notice 7d462f8f37da4a9a85e5e2fe97462bd6
January 22, 2026
Combined synopsis and solicitation
Due February 3, 2026 at 11:00 AM EST. SAM.gov, notice a734a577543e4e528a21345a01e9b514
January 27, 2026
Combined synopsis and solicitation
Due February 3, 2026 at 11:00 AM EST. SAM.gov, notice 74f199acaa56403187ece0933cfe0985
April 1, 2026
Award notice
Awarded to Atz Solution LLC Charlotte 28202 NCL for $165,000. SAM.gov, notice fc6ff3e4b51b41179400d5dedd196903
Points of contact
- ARLENE A. BLADE, CONTRACTNG OFFICERarlene.blade@va.gov(318) 466-4281
Also open from this buyer
- RadiopharmaceuticalsCombined synopsis and solicitationNAICS 325412New Orleans, LA36C25626Q1210Closes todaySep 17
- 629-27-1-6789-0002 DENTAL UNIT AIR COMPRESSOR REPLACEMENTCombined synopsis and solicitationSDVOSBNAICS 33911436C25626Q1240Closes todaySep 17
- 36C25626Q1271-Veteran Lodging Hop-Tel Services for the G.V. Sonny Montgomery VA Medical Center, Jackson MS, 39216Combined synopsis and solicitationSDVOSBNAICS 721110Jackson, MS36C25626Q1271Closes tomorrowSep 18
- Home Oxygen and Ventilator Services - VISN 16SolicitationSDVOSBNAICS 621610Ridgeland, MS36C25626R0037Closes in 4 daysSep 21
- RFI/Sources Sought Notice, Heterotrophic Plate Count (HPC) Waterline Testing Services, Biloxi, MS, Pensacola, FL and Panama City Beach, FLSources soughtNAICS 541380Biloxi, MS36C25626Q1337Closes in 6 daysSep 23