Presolicitation
Stryker Surgical Video Equipment
36C25526Q0665_1
Department of Veterans Affairs, 255-Network Contract Office 15. Surgical and Medical Instrument Manufacturing.
Offers due
September 22, 2026 at 9:00 AM EDT
6 days from now. Posted September 15, 2026.
Description
As published on SAM.gov.
This solicitation is for the purchase of Brand Name Stryker Video Equipment for the Wichita VAMC. See the following Solicitation for further information.
Camera Control Unit
Quantity: 6 EA
Specification/Salient Characteristics:
- Minimum resolution: 4K
- Scalable to accommodate future advancements in peripheral device integration and control
- The ability to assess perfusion for open surgery
- Intuitive capacitive touch screen LCD interface for ease of operation
- Capable of accommodating up to 10 different surgical specialties settings for optimal color resolution and brightness
- User-friendly and easily understood by nursing staff
- The ability/compatibility to see lighted ureteral stents that when placed, emits infrared light that can be detected to visualize the ureters (critical anatomy) in real time
- The ability to see fluorescence in 4K and lighted ureteral stents simultaneously
- CF Rated
- Capable of visualizing and highlighting lung and ovarian cancer
- Can showcase over 1 billion reproducible colors
- Includes dynamic range enhancements that improve visualization in both the highlights and shadows of the picture to increase clarity and details across the image
- Has technology been built into the system designed to reduce the effects of RF
- 5 advanced imaging modes of fluorescence for visualization to accommodate multiple specialties all in 4K
Light Source
Quantity: 6 EA
Specification/Salient Characteristics:
- It has technology that is designed to increase patient and operating rooms safety by minimizing the amount of time the light source is on, making patient and drape burns less likely
- Gives real time adjustments of light output to optimize visualization in every surgical scene
- 2 infrared lasers for advanced imaging (fluorescence/lighted stents)
- Gives visualize feedback to showcase when light cable is properly seated
32” 4K Wireless Transmitter
Quantity: 4 EA
Specification/Salient Characteristics:
- Wirelessly transmits 4K and 1080p signals
- Improve safety and workflow efficiencies in the OR
- Eliminate tripping hazards from cabling on the ground
- Enable a seamless linking process with LED confirmation & permanent and non-permanent pairing options
32” 4K Wireless Receiver
Quantity: 3 EA
Specification/Salient Characteristics:
- Wirelessly receives 4K and 1080p signals
- Improve safety and workflow efficiencies in the OR
- Eliminate tripping hazards from cabling on the ground
- Enable a seamless linking process with LED confirmation & permanent and non-permanent pairing options
32” 4K OLED Surgical Display & Covers
Quantity: 11 EA
Specification/Salient Characteristics:
- Resolution: 4096 x 2160
- Size: 32” corner to corner
- Ability to represent 1.07 billion different colors
- Offers crisp contrast ratio of 1,000,000:1
- OLED technology with self-illuminating pixels, eliminating the need for external backlighting
- 0.1 ms response time for no detectable image lag
- 14.0 lbs. for easy installation in both integrated and cart-based rooms
- 9 preset surgical specialties
- Includes 32" 4K OLED display covers
OLED Surgical Display Cover
Quantity: 11 EA
Specifications/Salient Characteristics:
- Intended to protect your displays from scratches/damage prolonging your investment
- Easily removable for cleaning
- Quick and seamless “install”
- Highly durable
Camera Head
Quantity: 12 EA
Specification/Salient Characteristics:
- CMOS 3-Chip camera technology designed for enhanced light sensitivity and increased patient safety
- Programmable to control OR equipment from camera head
- Ergonomic lightweight design for minimally invasive surgery
Insufflator
Quantity: 6 EA
Specifications/Salient Characteristics:
- Enhances image clarity
- For laparoscopic and robotic surgery
- Removes surgical smoke for a safer work environment
- 6 unique operating modes
- All-inclusive system with integrated heating, humidification, and smoke evacuation capabilities
- 4 interchangeable tube set options
Light Cable
Quantity: 12 EA
Specifications/Salient Characteristics:
- Scope sensing technology that automatically turns the light off when the scope is disconnected from the light cable
- Fiber optic cable
- Compatible Advanced Imaging modes
- Fluorescence
- Consistent lighting in small cavities
- Auto light feature
- Overlay mode to highlight ICG
- Contrast mode
Portable Handheld Fluorescence Imager
Quantity: 1 EA
Specifications/Salient Characteristics:
- Intuitive operator controls
- Comfortable single-handed operation
- Indicated for fluorescence imaging of blood flow and tissue perfusion before, during, and after vascular, gastrointestinal, organ transplant, and plastic, microsurgical, and reconstructive surgical procedures
- System is used to perform intraoperative fluorescence imaging and visualization of the lymphatic system, including lymphatic vessels and lymph nodes
- 1080p x 60fps
- Indicated for use in adult and pediatric patients one month of age and older
- Combine enhanced fluorescence signal information with vivid white light images in real-time
- 4 fluorescence modes for visualization
- Software allows the surgeon to further evaluate the intensity of the fluorescence signal in real time through relative percentage values and a color maps mode
- The ability to visualize lymphatic channels through the skin.
Portable Handled Fluorescence Imager Video Processor
Quantity: 1 EA
Specifications/Salient Characteristics:
- Features a timer that is automatically activated when fluorescence is detected, and icons indicating ingress and the fluorescence assessment window
- Involves no ionizing radiation and utilizes a non-nephrotoxic fluorescence imaging agent with a very short half-life thus allowing surgeons to repeat intraoperative perfusion assessment numerous times throughout the procedure
- The ability to visualize lymphatic channels through the skin.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 36C25526Q0665_1.pdf289 KB, September 15, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
September 15, 2026
Presolicitation
Due September 22, 2026 at 9:00 AM EDT. SAM.gov, notice cb213b027e684eed8a0f60d3f1ecb84d
2 revisions on SAM
- September 15, 2026: publish, solicitation
- September 15, 2026: publish, presolicitation
Points of contact
- Tracie RaggsTracie.Raggs@va.gov
Also open from this buyer
- 589-24-450, Upgrade BLDG 26 Chillers l KCVA (VA-26-00063880) FY26 NRM OSSources soughtSDVOSBNAICS 23622036C25526Q0635Closes todaySep 16
- ROLLA PACKAGE 073 PT EQUIP/ COPresolicitationSDVOSBNAICS 33911236C25526Q0640Closes tomorrowSep 17
- ME - TRANSFER SWITCH MAINT BASE PLUS 5 - CO (VA-26-00004264) 589-26-3-5329-0002PresolicitationSmall businessMissouri36C255-26-AP-0031Closes tomorrowSep 17
- Telephone Operator Support Services l KCVA | Base plus four (4) option yearsSolicitationSDVOSBNAICS 561421Missouri36C25526Q0654Closes tomorrowSep 17
- Telephone Operator Support Services l KCVA | Base plus four (4) option yearsPresolicitationSDVOSBNAICS 561421Missouri36C25526Q0654_1Closes tomorrowSep 17