This solicitation is for the purchase of Brand Name Stryker Video Equipment for the Wichita VAMC. See the following Solicitation for further information.

Camera Control Unit

Quantity: 6 EA

Specification/Salient Characteristics:

  • Minimum resolution: 4K
  • Scalable to accommodate future advancements in peripheral device integration and control
  • The ability to assess perfusion for open surgery
  • Intuitive capacitive touch screen LCD interface for ease of operation
  • Capable of accommodating up to 10 different surgical specialties settings for optimal color resolution and brightness
  • User-friendly and easily understood by nursing staff
  • The ability/compatibility to see lighted ureteral stents that when placed, emits infrared light that can be detected to visualize the ureters (critical anatomy) in real time
  • The ability to see fluorescence in 4K and lighted ureteral stents simultaneously
  • CF Rated
  • Capable of visualizing and highlighting lung and ovarian cancer
  • Can showcase over 1 billion reproducible colors
  • Includes dynamic range enhancements that improve visualization in both the highlights and shadows of the picture to increase clarity and details across the image
  • Has technology been built into the system designed to reduce the effects of RF
  • 5 advanced imaging modes of fluorescence for visualization to accommodate multiple specialties all in 4K

      Light Source

Quantity: 6 EA

Specification/Salient Characteristics:

  • It has technology that is designed to increase patient and operating rooms safety by minimizing the amount of time the light source is on, making patient and drape burns less likely
  • Gives real time adjustments of light output to optimize visualization in every surgical scene
  • 2 infrared lasers for advanced imaging (fluorescence/lighted stents)
  • Gives visualize feedback to showcase when light cable is properly seated

      32” 4K Wireless Transmitter

Quantity: 4 EA

Specification/Salient Characteristics:

  • Wirelessly transmits 4K and 1080p signals
  • Improve safety and workflow efficiencies in the OR
  • Eliminate tripping hazards from cabling on the ground
  • Enable a seamless linking process with LED confirmation & permanent and non-permanent pairing options

     32” 4K Wireless Receiver

Quantity: 3 EA

Specification/Salient Characteristics:

  • Wirelessly receives 4K and 1080p signals
  • Improve safety and workflow efficiencies in the OR
  • Eliminate tripping hazards from cabling on the ground
  • Enable a seamless linking process with LED confirmation & permanent and non-permanent pairing options

   

      32” 4K OLED Surgical Display & Covers

Quantity: 11 EA

Specification/Salient Characteristics:

  • Resolution: 4096 x 2160
  • Size: 32” corner to corner
  • Ability to represent 1.07 billion different colors
  • Offers crisp contrast ratio of 1,000,000:1
  • OLED technology with self-illuminating pixels, eliminating the need for external backlighting
  • 0.1 ms response time for no detectable image lag
  • 14.0 lbs. for easy installation in both integrated and cart-based rooms
  • 9 preset surgical specialties
  • Includes 32" 4K OLED display covers

      OLED Surgical Display Cover

            Quantity: 11 EA

            Specifications/Salient Characteristics:

  • Intended to protect your displays from scratches/damage prolonging your investment
  • Easily removable for cleaning
  • Quick and seamless “install”
  • Highly durable

      Camera Head

            Quantity: 12 EA

            Specification/Salient Characteristics:

  • CMOS 3-Chip camera technology designed for enhanced light sensitivity and increased patient safety
  • Programmable to control OR equipment from camera head
  • Ergonomic lightweight design for minimally invasive surgery

      Insufflator

            Quantity: 6 EA

            Specifications/Salient Characteristics:

  • Enhances image clarity
  • For laparoscopic and robotic surgery
  • Removes surgical smoke for a safer work environment
  • 6 unique operating modes
  • All-inclusive system with integrated heating, humidification, and smoke evacuation capabilities
  • 4 interchangeable tube set options

      Light Cable

           Quantity: 12 EA

           Specifications/Salient Characteristics:

  • Scope sensing technology that automatically turns the light off when the scope is disconnected from the light cable
  • Fiber optic cable
  • Compatible Advanced Imaging modes
    • Fluorescence
    • Consistent lighting in small cavities
    • Auto light feature
    • Overlay mode to highlight ICG
    • Contrast mode

      Portable Handheld Fluorescence Imager

            Quantity: 1 EA

            Specifications/Salient Characteristics:

  • Intuitive operator controls
  • Comfortable single-handed operation
  • Indicated for fluorescence imaging of blood flow and tissue perfusion before, during, and after vascular, gastrointestinal, organ transplant, and plastic, microsurgical, and reconstructive surgical procedures
  • System is used to perform intraoperative fluorescence imaging and visualization of the lymphatic system, including lymphatic vessels and lymph nodes
  • 1080p x 60fps
  • Indicated for use in adult and pediatric patients one month of age and older
  • Combine enhanced fluorescence signal information with vivid white light images in real-time
  • 4 fluorescence modes for visualization
  • Software allows the surgeon to further evaluate the intensity of the fluorescence signal in real time through relative percentage values and a color maps mode
  • The ability to visualize lymphatic channels through the skin.

        Portable Handled Fluorescence Imager Video Processor

              Quantity: 1 EA

              Specifications/Salient Characteristics:

  • Features a timer that is automatically activated when fluorescence is detected, and icons indicating ingress and the fluorescence assessment window
  • Involves no ionizing radiation and utilizes a non-nephrotoxic fluorescence imaging agent with a very short half-life thus allowing surgeons to repeat intraoperative perfusion assessment numerous times throughout the procedure
  • The ability to visualize lymphatic channels through the skin.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. September 15, 2026

    Presolicitation

    Due September 22, 2026 at 9:00 AM EDT. SAM.gov, notice cb213b027e684eed8a0f60d3f1ecb84d

    2 revisions on SAM
    • September 15, 2026: publish, solicitation
    • September 15, 2026: publish, presolicitation

Points of contact