The project will install an exterior door and stairs for roof access in the stairwell between the 2nd and 3rd floors in Building 1 of the John J. Pershing VA Health Care System, Poplar Bluff, MO. This will require the removal of an existing window, installing a roof access door into the existing window opening, and installing exterior metal stairs with handrails for access to the roof. Access door and hardware shall be compatible with VA TIL design requirements (core to be provided by VA).
All aspects of the design must be OSHA compliant, and an exterior platform is acceptable if deemed required to meet standards. The project will also install a patient platform stair lift for motorized wheelchair from the ground floor staircase to the Lower-level Urgent care. The lift shall have a Minimum lift capacity of 400lbs and ability to fold and store away from foot traffic adjacent to stairwell. Lift shall be an Artira type lift manufactured by Garaventa Lift Company or equal.
Contractor responsible for modifications to stairwell for complete installation. Power requirements as required by manufacturer and to be installed on isolated circuit back to existing Urgent Care electrical closet by contractor. Flexible electrical conduit (MC Cable) is not permissible and must be solid piped.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- 4GKB, LLC
- UEI
- L9CPNQL6S2A9
- CAGE
- 9PPL2
- Vendor location
- Kansas City, MO
- Contract
- 36C25524C0066, definitive contract
- Obligated
- $210,142.00
- Actions
- 4 between September 9, 2024 and May 3, 2025
- Competition
- Full and Open Competition After Exclusion of Sources, 2 offers received
- Set-aside reported
- Service Disabled Veteran Owned Small Business SET-ASIDE
- Described as
- 657A4-24-104 Urgent Care Access Improvement
- Match
- solicitation number 36C25524R0085 equals the FPDS solicitation identifier; same awarding office 36C255 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 14, 2024
Presolicitation
657A4-24-104, Urgent Care Access Improvement
Due August 1, 2024 at 3:00 PM EDT. SAM.gov, notice 8597f0a2a7aa44d182be9e32d75b94b3
July 12, 2024
Solicitation
Due August 15, 2024 at 3:00 PM EDT. SAM.gov, notice e9c83fce7d664fce956259f99896814f
July 25, 2024
Solicitation
Due August 15, 2024 at 3:00 PM EDT. SAM.gov, notice 501dfef4c0144bc2ad974362f9b9dc02
Points of contact
- Abby L Monroeabby.monroe2@va.gov9139469916
- Cedric GrahamCedric.Graham@va.gov9139461141
Also open from this buyer
- 36C25526Q0650 657-27-101, FCA-Conduct Hazardous Material Abatement, 2027 AE Design -FY27 NRMSources sought36C25526Q0650Closes todaySep 18
- Uninterruptible Power Supply St. Louis VA Medical CenterSources soughtNAICS 81121036C25526Q0678Closes todaySep 18
- Induction Charger for food warmerSources soughtSDVOSBNAICS 335999Kansas City, MO36C25526Q0657Closes todaySep 18
- BACKFLOW ANNUAL INSPECTION, TESTING & MAINTENANCE MARION, IL VA MEDICAL CENTERSources soughtSDVOSBNAICS 238220Illinois36C25527Q0005Closes todaySep 18
- Primescan AC Intraoral CAD/CAM Scanner (Cart Configuration) - Brand Name OnlySources soughtNAICS 339114Wichita, KS36C25526Q0667Closes todaySep 18