Solicitation
SPS Water Testing and Maintenance
36C25224Q0147
Department of Veterans Affairs, 252-Network Contract Office 12. Testing Laboratories and Services.
Response deadline
February 5, 2024 at 4:00 PM EST
Closed 1000 days ago. Posted February 1, 2024, first published January 4, 2024. Scheduled to archive March 6, 2024.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2024
23 like it are open now in testing laboratories and services
- Granite Surface Plate Calibration and lapping - with Q&As
Department of the Army, W6QK ACC-RI
Combined synopsis and solicitationNAICS 541380Rock Island, ILW519TC27QA007Closes in 8 daysNov 9 - VACCHCS Pharmacy Certification
Department of Veterans Affairs, 261-Network Contract Office 21
Combined synopsis and solicitationNAICS 541380Fresno, CA36C26127Q0099Closes tomorrowNov 2 - Troubleshooting, Calibration and as-needed Remedial Repair of Proof Test Machines
Department of the Navy, Pearl Harbor Naval Shipyard Imf
SolicitationSmall businessNAICS 541380HawaiiN32253-27-Q-0001Closes tomorrowNov 2
Description
As published on SAM.gov.
36C25224Q0147 CONTINUATION PAGES NEW QUESTIONS AND ANSWERS HIGHLIGHTED BELOW Questions Answers How easily if it to access the water treatment equipment? (equipment location and pictures of the equipment installed) The equipment is not difficult to access. It is in room 3603 in the Bed Tower mechanical room which is indicated on the attached RO System Bed Tower-Floor plan for the inhouse SPS system. We also have a temporary SPS trailer that is accessed from outside by the Polk Street Dock.
Contractors would need to be provided a key or be escorted when onsite so they can access the water rooms where the equipment is located. Pictures of existing RO System (need to see how easily it is to access number of membranes and pre filters) Attached IMG 2410. Feet of DI Loop to be disinfected? DI is set up next to the RO, and piping length is minimal. Contractor responsible for chemically disinfecting SPS system. Pictures, type of valve head and size of Carbon filters? Onsite visit during scheduled tour.
Number and size of DI Tanks Only needed in event of emergency used as a backup system. How many Post Filters are on the system? 2 DI Tanks are only needed in event of emergency and are used as a backup system. What type/size would be needed for the backup? 3.6 cubic foot mix bed type 1, 4-inch size RO and vessel name plate with the serial number. Picture attached
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
January 4, 2024
Solicitation
Due January 18, 2024 at 11:00 AM EST. SAM.gov, notice 317ada2a9e254c9480eac19a6712c786
January 16, 2024
Solicitation
Due February 5, 2024 at 4:00 PM EST. SAM.gov, notice f7c305f7e33241bebba4a6a8d2386fc2
January 22, 2024
Solicitation
Due February 5, 2024 at 4:00 PM EST. SAM.gov, notice 7ff1f662e81f4ea1b44534e4b19efdea
January 23, 2024
Solicitation
Due February 5, 2024 at 4:00 PM EST. SAM.gov, notice 4b278feeea6448309bd6e0d31164e571
February 1, 2024
Solicitation
Due February 5, 2024 at 4:00 PM EST. SAM.gov, notice 118821432ff649a8b5f2f3a6c4df91a6
Points of contact
- Laura A Broacha, ContractorLaura.Broacha@va.gov