Combined synopsis and solicitation, total small business set-aside
Retrofit Washer Disinfector
36C24826Q0718
Department of Veterans Affairs, 248-Network Contract Office 8. Surgical Appliance and Supplies Manufacturing.
Awarded
$46,743.24 obligated so far on USAspending
Description
As published on SAM.gov.
Retrofit Washer Disinfector with AcuDose System GENERAL: James A. Haley Veterans Hospital (JAHVH), located at 13000 Bruce B. Downs Blvd, Tampa, FL 33612, has a requirement for the Steris AcuDose Retrofit Kit for 7053HP Washer Disinfectors to support compliant chemical dosing operations in the Sterile Processing Service (SPS).
BACKGROUND: The Sterile Processing Service (SPS) currently provides critical instrument reprocessing functions that depend on accurate chemical dosing and reliable washer disinfector performance. The existing Steris Amsco 7053HP washers were installed before AcuDose technology was available, and SPS now relies on eighteen aging chemical delivery lines that no longer meet operational or reliability requirements.
To ensure continued compliance with national standards, maintain compatibility with existing Steris systems, and improve dosing accuracy, workflow consistency, and overall performance, SPS requires an OEM approved equipment upgrade that retrofits the current 7053HP washers with the AcuDose system and replaces the outdated delivery lines.
SCOPE: The contractor shall furnish all labor, materials, and OEM certified Steris technicians to provide and install the Steris brand name AcuDose Retrofit Kit for the 7053HP Washer Disinfectors. Use of the Steris brand name AcuDose Retrofit Kit is required to ensure full system compatibility, maintain standardization of Steris equipment across the facility, and preserve warranty and safety requirements.
The contractor shall disconnect, extract, and remove all eighteen (18) existing chemistry delivery lines routed through PVC conduits from the dosing room to the washers. Following removal, the contractor shall install and retrofit the AcuDose system on the three (3) 7053HP washer disinfectors located in the SPS decontamination area. All retrofit work shall be performed one washer at a time to maintain continuous SPS operations.
This project requires no FMS support, as no electrical or plumbing modifications are needed. Upon installation of each AcuDose retrofit, the contractor shall verify proper system operation and functionality. The contractor shall also provide on site in service training to SPS staff to ensure correct operation of the upgraded equipment. All work must be performed in accordance with applicable VA standards and exclusively by technicians certified to work on Steris equipment.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Beacon Point Associates LLC
- UEI
- L97MMG5VW9N7
- CAGE
- 6U5B7
- Vendor location
- Cape Coral, FL
- Contract
- 36C24826P1081, purchase order
- Obligated
- $46,743.24
- Actions
- 1 between July 23, 2026 and July 23, 2026
- Competition
- Competed Under SAP, 2 offers received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- Retrofit Washer/Disinfector with Acudose System
- Match
- solicitation number 36C24826Q0718 equals the FPDS solicitation identifier; same awarding office 36C248 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 9, 2026
Combined synopsis and solicitation
Due July 17, 2026 at 5:00 PM EDT. SAM.gov, notice 7322eeb657c34e3da05f56406004b904
Points of contact
- Quentin Ford, Contract SpecialistQuentin.Ford@va.gov813-595-5964
Also open from this buyer
- Commercial Mowers for Bay Pines VA Health Care SystemSolicitationSmall businessNAICS 333111Florida36C24826Q1118Closes todaySep 16
- FY26: MBC Sternudrive LiteTM; Model MBC 709-ModularSolicitationNAICS 339112Puerto Rico36C24926Q0926Closes todaySep 16
- Commercial Street VacuumCombined synopsis and solicitationSmall businessNAICS 333112Florida36C24826Q1249Closes tomorrowSep 17
- Street Debris BlowersCombined synopsis and solicitationSmall businessNAICS 333112Florida36C24826Q1251Closes in 2 daysSep 18
- PHARMACY IV PREP SYSTEMSources soughtNAICS 541519Puerto Rico36C24826Q1191_1Closes in 2 daysSep 18