Skip to content
Abierto

Combined synopsis and solicitation, service-disabled veteran-owned small business set-aside

Ceiling Mounted Patient Lifts 5-North & 5-West

36C24825Q0622

Department of Veterans Affairs, 248-Network Contract Office 8. Surgical Appliance and Supplies Manufacturing.

Awarded

Electra-Med Corporation

$188,108.65 obligated so far on USAspending

Description

As published on SAM.gov.

STATEMENT OF NEED Ceiling-Mounted Patient Lifts Replacement for 5-North and 5-West Inpatient Units GENERAL: James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for ceiling-mounted patient lifts in two inpatient units to replace outdated patient lifts. The patient lifts will be used for patient transfers and repositioning in bed and will be installed in existing rail systems.

BACKGROUND: James A. Haley VA Hospital is soliciting a contractor to furnish all design, site evaluation, labor, materials, equipment, and installation of ceiling-mounted patient care lifts in the existing inpatient units: 5-North and 5-West. Numerous utility systems occupy this space and must be considered when installing new equipment above the ceiling and in the existing patient lift support rails. It is strongly recommended that the contractor perform a thorough site evaluation prior to submitting a proposal.

SCOPE: The Contractor shall provide a technical and cost proposal for turn-key services to install ceiling-mounted patient lifts in accordance with this scope of work. This cost proposal shall be for providing new installation and removal/de-installation of LIKO Brand Name Only patient lift units including but not limited to:

lift devices, support material, gate transition pieces and all other associated components required for complete, functional installation for ceiling lift in with scale and hand-control based charged ceiling lift systems. This proposal shall also be for installation of the lift systems including but not limited to any required plans, engineering details and documents, tools, labor, testing, training, cleaning supplies, etc. All new lift systems must have a lifting capacity of no less than 507 lbs.

Operation of the system must be smooth with no fast or jerky starts and stops. Operation of the system must allow for adequate lifting height allowing for transfer of patient from bed. All lift systems must have the availability to weigh a patient in kilograms and pounds. Existing hangers, Unistrut, or other support components shall not be utilized to support the lift tracks. If additional supports are needed, new supports must be connected directly to building structural components.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
N219L1VNM7E4
CAGE
0P8N4
Vendor location
Flint, MI
Contract
36C24825P1181, purchase order
Obligated
$188,108.65
Actions
1 between May 9, 2025 and May 9, 2025
Competition
Competed Under SAP, 1 offer received
Set-aside reported
Service Disabled Veteran Owned Small Business SET-ASIDE
Described as
Liko Ceiling Mounted Patient Lift Motors
Match
solicitation number 36C24825Q0622 equals the FPDS solicitation identifier; same awarding office 36C248 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. April 16, 2025

    Combined synopsis and solicitation

    Due April 23, 2025 at 10:00 AM EDT. SAM.gov, notice 535d8d6b487242f386ab2ff73876c208

  2. April 17, 2025

    Combined synopsis and solicitation

    Due April 23, 2025 at 10:00 AM EDT. SAM.gov, notice 1f5083077f8c4aa4b21b75c9fa62311e

Points of contact