Skip to content
Abierto

Sources sought, service-disabled veteran-owned small business set-aside

MRI Breast Coil with Training

36C24824Q1369

Department of Veterans Affairs, 248-Network Contract Office 8. Electromedical and Electrotherapeutic Apparatus Manufacturing.

Awarded

Trillamed LLC

$56,695.00 obligated so far on USAspending

Description

As published on SAM.gov.

Sources Sought The Department of Veterans Affairs, James A. Haley Veterans Hospital (JAVH) located at 13000 Bruce B. Downs, Tampa, Fl. 33612 is issuing a sources sought notice as a means of conducting market research to identify parties having an interest in and the resources to support this requirement for BRAND NAME ONLY MRI breast coil, imaging software sequence VIBRANT and onsite training manufactured by GE Precision Healthcare, LLC. DELIVERABLES/ SPECIFIC NEED: 1. Qty (1) M7000EG Vibrant 2. Qty (1) M3335LA 3.0T 8-Channel Breast Array (with Biopsy Grids) 3. Qty (5) W0330MR Tip Day of Applications Training PHYSICAL CHARACTERISTICS:

1. VIBRANT (Volume Imaged Breast AssessmeNT) is a fast, high resolution T1 weighted imaging sequence and application optimized for evaluation of breast tissue. VIBRANT uses GE exclusive technology and parallel imaging acceleration to quickly acquire multi-phase data without compromising spatial resolution.

This 3D gradient echo technique, optimized for sagittal or axial acquisitions, uses an optimized inversion pulse and dual-shimming technology that yields enhanced image contrast and robust, uniform, bilateral fat suppression. Auto subtraction of the first dataset is also available to further background suppression. For enhanced speed, VIBRANT is compatible with both ASSET and ARC parallel imaging with acceleration factors up to four. As a result, VIBRANT enables reliable, high quality breast imaging.

2. The 3.0T Breast Array generates high-definition MR breast images. Optimized for use with ASSET and VIBRANT for up to 3X acceleration, this 8-element phased-array coil helps ensure excellent temporal and spatial resolution, patient after patient. The array is also compatible with Fast Spin Echo, Fast Gradient Echo, and Diffusion Imaging sequences. It provides uncompromised lateral and medial biopsy access.

3. A single day of applications training delivered at customer s site for any GE Healthcare Diagnostic Imaging system. Training will be delivered at a mutually agreed upon time between the customer and GE Healthcare (excluding GE Healthcare holidays) and are subject to availability. Training must be completed within 12 months from purchase. THERE IS NO SOLICITATION AT THIS TIME.

This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.

If your organization has the potential capacity to perform these contract services, please provide the following information: 1) Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization; and 2) Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability.

If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements. Authorization letter from the Original Equipment Manufacturer (OEM). Service Disabled Veteran Owned Small Businesses (SDVOSBs) or Veteran Owned Small Businesses (VOSBs) must be verified and certified in VETCERT.

Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed products and services are invited to submit a response to this sources sought notice by 07/25/2024. All responses under this sources sought notice must be emailed to Leonora simmons@va.gov no later than 07/25/2024 at 10 am EST.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

Recipient
Trillamed LLC
UEI
GW9FLBWB5625
CAGE
56FN2
Vendor location
Bingham Farms, MI
Contract
36C24824P2058, purchase order
Obligated
$56,695.00
Actions
1 between July 31, 2024 and July 31, 2024
Competition
Not Competed Under SAP, 1 offer received
Set-aside reported
Sdvosb Sole Source
Described as
MRI Breast Coil
Match
solicitation number 36C24824Q1369 equals the FPDS solicitation identifier; same awarding office 36C248 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 19, 2024

    Sources sought

    Due July 25, 2024 at 10:00 AM EDT. SAM.gov, notice 3a460dfb375c4b379706ab5d1d38b98f

Points of contact