Sources sought
Ceiling Mounted Patient Lifts
36C24726Q0279
Department of Veterans Affairs, 247-Network Contract Office 7. Surgical Appliance and Supplies Manufacturing.
Response deadline
February 24, 2026 at 1:00 PM EST
Closed 256 days ago. Posted February 9, 2026. Scheduled to archive March 11, 2026.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2026
23 like it are open now in surgical appliance and supplies manufacturing
- Sterile Storage Cabinets
Department of Veterans Affairs, 262-Network Contract Office 22
Sources soughtNAICS 339113Anywhere in the US36C26227Q0097Closes in 2 daysNov 9 - LIFE PRESERVER,VEST
Defense Logistics Agency, DLA Troop Support
Combined synopsis and solicitationWOSBNAICS 339113Anywhere in the USSPE8E927T0346Closes in 3 daysNov 9 - FIREMAN'S HELMET
Defense Logistics Agency, DLA Troop Support
Combined synopsis and solicitationWOSBNAICS 339113Anywhere in the USSPE8E627T0376Closes in 3 daysNov 9
All 23 open in surgical appliance and supplies manufacturing
Description
As published on SAM.gov.
The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre-Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or proposals at this time; however, reserves the right to do so at a later date. The Charleston SC VA Medical Center is seeking to identify potential sources for ceiling mounted patient lifts in accordance with VHA Directive 1116. Below are the requested U.S. MADE products ONLY:
- Must be able to handle a maximum load of 550 lbs.
- Must have a 2 x 12 V (2.4 Ah - 2.6 Ah), Valve-regulated lead-acid gel-type batteries. New batteries are provided by the supplier.
- Must have a battery charger that falls within SMP CC-10-43-24; 100-240 V AC, 40-60 Hz, max 600 mA , IRC (In-Rail Charging): CH01 FW7218M/24; 100-240 V AC, 50-60 Hz, max 500 mA.
- Lifting speed must be 50 mm/s (2 inch./s).
- Must have a lifting interval of 2050 mm (80.7 inch.
- Electrical functioning must me within 24V, 12A.
- Must have an intermittent operation of 10/90, active operation of max 30 sec.
- Must have an emergency lowering device.
- Must function between the temperatures of 50F – 122F.
- Must be compatible with LIKORALL/LIKO Rail system.
*NOTE: All interested parties must
o Have an active registration in the System for Award Management (SAM) database. To register, please visit www.SAM.gov.
o Clearly express/document that the requested items are Made in America ONLY (by completion of the FAR 52.225-2; Buy American Certificate (Oct 2022).
o Include current documentation of authorized reseller information, if applicable.
Responses to this notice shall include:
Company Name
Address
Point of Contact
Phone Number
Email Address
UEI Number
CAGE Code
Any other pertinent information
Please provide answers to all questions below regarding your firm’s Socio-Economic status pursuant to North American Industrial Classification Code (NAICS) 339113, Surgical and Medical Instrument Manufacturing.
1. Is your business a small business under NAICS 339113? YES ______ NO ______
2. Is your firm a Veteran-Owned Small Business? YES ______ NO ______
3. Is your firm a Service-Disabled Veteran-Owned Small Business? YES ______ NO ______
4. Is your firm a certified HUB Zone firm? YES ______ NO ______
5. Is your firm a Woman Owned business? YES ______ NO ______
6. Is your firm a Large Business? YES ______ NO ______
7. Is this item available via your GSA/FSS/SEWP schedule? YES ______ NO ______
Schedule Number: ___________________
Expiration Date: ____________________
Please provide a capability statement as well as any relevant literature addressing your
organization’s ability to supply the required MADE IN AMERICA items. Also, please include a
point of contact name, phone number and email address, as requested above.
**Also note the applicable clauses related to this requirement:
- FAR 52.225-1; Buy American-Supplies
- FAR 52.225-2; Buy American Certificate
Questions regarding this notice should be addressed to Mary Jane Coffman via email only. Faxes
and phone calls will not be accepted.
Please submit all responses to this notice via e-mail to:
Mary Jane Coffman, Contract Specialist
mary.coffman@va.gov
Responses to this Request for Information Notice are required by no later than Monday,
February 24, 2026 at 1:00 PM EST.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Sources Sought - Ceiling Mounted Patient Lift.docx17 KB, February 9, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
February 9, 2026
Sources sought
Due February 24, 2026 at 1:00 PM EST. SAM.gov, notice cfaf8ce9234e465b8d80244cbf426661
1 revisions on SAM
- February 9, 2026: publish, sources sought
Points of contact
- Mary Jane Coffmanmary.coffman@va.govN/A