Award notice, service-disabled veteran-owned small business set-aside, first published as combined synopsis and solicitation
WNY Air Monitoring & Hazardous Material Sampling IDIQ
36C24224Q0327
Department of Veterans Affairs, 242-Network Contract Office 02. Remediation Services.
Awarded
$0.00 obligated so far on USAspending
Description
As published on SAM.gov with the combined synopsis and solicitation of March 27, 2024.
This amendment is to answer the following vendor questions: In line 12 of the Air monitor ACM IDIQ Bid sheet I changed the Turnaround time to 1 week because it was a duplicate of line 11(they both said 24hr TAT). Please let me know if this was not a correct assumption. That is correct the turn around time for line item 12 of the Air monitor ACM IDIQ Bid sheet should have a turn around time of one week, not 24 hours.
Can you please clarify the need for Provide services of a Certified Air Sampling Technician during the asbestos air quality monitoring and sampling activities as a stand-alone bid item? SOW B.3.1.4 Air Monitoring (E) states Contractor shall continuously inspect and monitor conditions inside the work areas to ensure compliance with all regulations . The contractor shall collect all required area samples and analyze all air samples within 24 hours of collection.
The contractor shall continuously inspect work areas for any breaches in containment. Contractor shall maintain a daily log of all air monitoring samples and daily activity log. Containment shall stay in place until the clearance samples come back clear and has received authorization from the COR to end containment.
This means a project monitor will be required daily on task orders. An air sampler can only set up pumps/cassettes, retrieve pumps/cassettes, submit them to the lab, and maintain and air sampling log. An air sampler is not certified to continuously inspect and monitor conditions inside/outside the work area and is not required to maintain a daily activity log. Those responsibilities fall under Project Monitor.
This gives the contractor flexibility to offer the sampling technician and project monitor separately providing best value to the VA in the event more than one person is needed, rather than being billed for multiple project monitors. Can you please clarify SOW B.3.1.4 Air Monitoring (F) & (G)?  Section F states If visual inspection is acceptable, the contractor shall proceed with clearance air samples, using aggressive method. Samples shall be analyzed using the PCM method.
All PCM samples shall be analyzed using the NIOSH 7400 method. Onsite testing is preferred.  Onsite testing is not permitted by CR-56 for air sampling unless the individual is certified by NYSDOH ELAP. Otherwise, it must be performed by a laboratory. The VA agrees with this statement. Onsite testing is preferred shall be removed from section B.3.1.4 Air Monitoring (F). Section G states Final clearance samples shall be conducted in accordance with TEM NIOSH 7402 method.
TEM NIOSH samples shall be collected for areas greater than 160 square feet only. TEM for clearance samples is estimated 12 samples per clearance estimated. Contractor shall ensure that NESHAP testing is performed for all renovation and demolition work by asbestos contractors. It includes destructive sampling that AHERA does not cover.
Section G appears to be a direct contradiction to Section F. By CR-56, clearance samples can be collected and analyzed using PCM methods for any size of project. If a sample fails, all samples can be re-analyzed using TEM Method 7402. It might be more consistent throughout all task orders to request AHERA TEM sampling for all clearance samples regardless of the size of project or require PCM clearance samples regardless the size of the project per CR-56 and if they fail, then use Method 7402.   The VA agrees with this recommendation The VA agrees with this statement.
Section B.3.1.4 Air Monitoring (G) shall now state: Final clearance samples shall be conducted using PCM clearance samples regardless the size of the project per CR-56. If a sample fails, all samples shall be re-analyzed using TEM Method 7402. Â Contractor shall ensure that NESHAP testing is performed for all renovation and demolition work by asbestos contractors. All other terms and conditions remain the same.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Trine Environmental Inc.
- UEI
- VX75EQLTUK61
- CAGE
- 6R2M5
- Vendor location
- Brighton, MI
- Contract
- 36C24224D0035
- Obligated
- $0.00, potential $2,400,000
- Actions
- 2 between April 16, 2024 and May 29, 2026
- Competition
- Competed Under SAP, 7 offers received
- Set-aside reported
- Service Disabled Veteran Owned Small Business SET-ASIDE
- Described as
- Idc for Asbestos Air Monitoring and Material Sampling Services
- Match
- award number 36C24224D0035 equals the contract number; same awarding office 36C242 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
March 12, 2024
Combined synopsis and solicitation
Due March 26, 2024 at 12:00 PM EDT. SAM.gov, notice 2c88ab067b9445d59987b4bf49bbaf7b
March 14, 2024
Combined synopsis and solicitation
Due April 5, 2024 at 12:00 PM EDT. SAM.gov, notice 2f8e8e5395c74ef7bdf210dcdd35ac87
March 27, 2024
Combined synopsis and solicitation
Due April 5, 2024 at 12:00 PM EDT. SAM.gov, notice b43715a410a84d8aaae9ce2d22eeda06
June 7, 2024
Award notice, originally combined synopsis and solicitation
Awarded to Trine Environmental Inc. Brighton 48116 for $0. SAM.gov, notice 8179a2ecaa12433f9fd7fb97b9ba091b
Points of contact
- Michael.Spivack@va.gov, Spivack, MichaelMICHAEL.SPIVACK@va.gov(716)862-8890
Also open from this buyer
- Sources Sought Bath VAMC Generator Service ContractSources soughtNAICS 811310Bath, NY36C24226Q0917Closes todaySep 17
- Sources Sought Building Management SystemSources soughtNAICS 811210Canandaigua, NY36C24226Q0991Closes todaySep 17
- Castle Point PT Flooring ReplacementSolicitationSDVOSBNAICS 238160Montrose, NY36C24226Q0920Closes tomorrowSep 18
- Urgent Chiller Plant PRV Valve 2 Repair Samuel S. Stratton (Albany) VAMCPresolicitationNAICS 238220Albany, NY36C24226Q0942Closes tomorrowSep 18