Skip to content
Abierto

Sources sought

Vaisala Humidity and Temperature Equipment

145034240076SM

National Oceanic and Atmospheric Administration, Department of Commerce NOAA. Other Measuring and Controlling Device Manufacturing.

Awarded

Vaisala Inc.

$28,707.00 obligated so far on USAspending

Description

As published on SAM.gov.

Notice Number:

145034240076SM Notice Type:

Sources Sought Synopsis Title:

Vaisala Humidity and Temperature Equipment Response Date: August 2, 2024 This is a SOURCES SOUGHT SYNOPSIS and is not a pre-solicitation announcement. The purpose of this Market Research and Sources Sought Notice is to gain knowledge of potential qualified U.S. Domestic businesses, which could include Small Business, HUBZone, 8(a), Service Disabled Veteran Owned, Women Owned Small Business firms and even Large Businesses.

Responses to this Sources Sought Synopsis will be used by the Government in making appropriate acquisition decisions. The National Oceanic and Atmospheric Administration (NOAA), Oceanic and Atmospheric Research (OAR), Earth Systems Research Laboratories (ESRL), Global Monitoring Laboratory (GML) manages four historical atmospheric baseline observatories (ABOs) in Alaska, Hawaii, American Samoa, and Antarctica with long continual historical records of atmospheric chemistry and meteorological measurements.

In addition to the ABOs, GML also manages a tall tower atmospheric measurement network (AMN) that is currently being enhanced with new meteorological sensors to supplement other atmospheric chemistry related observation data in order to improve data analysis capabilities. All of these sites use the Vaisala meteorological sensors and components for data collection, and new equipment like the Vaisala brand instruments is needed to maintain the existing network.

INTENDED USE/PURPOSE: Vaisala’s HMP155 Humidity and Temperature Probes, PTB330 Digital and Analog Barometers, MI70 Handheld Measurement Indicators, PTB210 Digital Barometers, and SPH20 Static Pressure Heads are needed to integrate into the current ABO and AMN systems, in order to continue long-term historical records. Additional instrumentation is needed in order to maintain the integrity of data sets, and consistency of measurements of atmospheric chemistry and meteorological data. These are the only known instruments that can meet the Government’s needs, and this notice’s intent is to identify any other products that meet the full requirements listed below.

SPECIAL REQUIREMENTS/ESSENTIAL SALIENT FEATURES: See attached data sheets for full specifications in order to meet the Government’s requirement.

HMP155 General Specifications: Long-term stability able to withstand harsh environments Solid structure protects sensor with sintered teflon filter Warmed probe able to provide reliable measurements in high-humidity environments Membrane filter for fast response time Calibration via USB cable, push buttons, or indicator PTB330 General Specifications: Highly accurate Class A barometer, calibrated against high-precision pressure calibrator Can incorporate 1, 2, or 3 BAROCAP sensors; when 2 or 3 sensors used, barometer continuously compares readings Can be set to compensate for QNH and QFE pressure Multilingual, graphical display; graph updates automatically during measurement Provides WMO pressure trend and tendency codes MI70 General Specifications: Multi-probe operation allows two probes to be connected simultaneously Indicator can display both probes for simultaneous data display multilingual, menu-based user interface with clear graphical LCD display Three measurement parameters can be displayed and logged in memory at once Measurement parameters can be displayed graphically and numerically Users can select measurement parameters and units Data transfer through USB connection PTB210 General Specifications: Designed to operate in wide temperature range and harsh environments Electronics housing provides IP65 (NEMA 4) standardized protection against sprayed water Available in two pressure ranges in three configurations (see data sheet for ranges/configurations) Higher accuracy barometer calibrated against a high-precision pressure calibrator Available for 500 to 1100 hPa pressure range Integrates directly with Vaisala Static Pressure Head Series Accurate measurement in all wind conditions Uses silicon capacitive absolute pressure sensor for barometric pressure applications SPH20 General Specifications: Designed to minimize errors caused by wind Horizontally and vertically symmetrical Reliable barometric pressure measurements in all weather Heated for reliable operation in snowy and icy conditions Thermostat automatically switches on warming power when appropriate Composted of ultraviolet stabilized PC plastics and offshore aluminum Protects against rain and condensed water, preventing capillary condensation Drain holes in lower plate allow rain and water flow out DELIVERY SCHEDULE: Deliver by 60 days after award.

The North American Industry Classification Code (NAICS) is 334519 with a size standard of 600 employees. Interested firms shall provide, in writing, a brief narrative (no more than 3 pages in length) and documentation to support your firm’s capability and experience meeting the requirements herein and include your firm’s name, address, point of contact, telephone number, UEID Number, CCR CAGE Number, business type and size (i.e., small, large, non-profit, educational, etc.).

Any response that does not include this information will not be considered. The Government will review your response to determine if your firm has the experience, knowledge and capability to provide the items as specified above. This request for information does not constitute a commitment, implied or otherwise, that a procurement action will be issued. Nor does this request for information constitute a commitment, implied or otherwise, that any procurement action may be issued for the Government’s requirements.

No entitlement to payment of direct or indirect costs or charges by the Government will arise because of the submission of contractor’s information. The Government shall not be liable for or suffer any consequential damages for proprietary information not properly identified. Proprietary information will be safeguarded in accordance with the applicable Government regulations. All contractors doing business with the Government are required to be registered and active with the System for Award Management (SAM) website.

NOTE: THIS SYNOPSIS IS NOT CONSIDERED A REQUEST FOR PROPOSAL BUT A REQUEST FOR INFORMATION ONLY. No solicitation document is available. No contract will be awarded based on responses received to this notice.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

Recipient
Vaisala Inc.
UEI
FCMPZKYCYKH5
CAGE
63653
Vendor location
Louisville, CO
Contract
1305M324P0468, purchase order
Obligated
$28,707.00
Actions
1 between August 27, 2024 and August 27, 2024
Competition
Not Competed Under SAP, 1 offer received
Set-aside reported
No Set Aside Used.
Described as
Purchase of Vaisala Humidity and Temperature Probes for Gml. Miao: 66b61cdc18a1cfd42c3caa82
Match
solicitation number 145034240076SM equals the FPDS solicitation identifier; same awarding office 1305M3 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 23, 2024

    Sources sought

    Due August 2, 2024 at 2:00 PM EDT. SAM.gov, notice 41be901d110847a385bf7649d0d7b3d8

Points of contact