Skip to content
  • 6,812 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell Abierto what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and Abierto tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans
AbiertoGet started

Solicitation, total small business set-aside

Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer

1333ND26QNB640601

National Institute of Standards and Technology, Department of Commerce NIST. Analytical Laboratory Instrument Manufacturing.

Awarded

Custom Solutions Group, Inc.

$85,863.00 obligated so far on USAspending

Get the next one like this from National Institute of Standards and Technology by email, the day it is posted.Find my opportunities

This one was awarded in 2026

39 like it are open now in analytical laboratory instrument manufacturing

All 39 open in analytical laboratory instrument manufacturing

Description

As published on SAM.gov.

***Amendment 0001****

Amendment 0001 provides resposnes to questions received in response to the solicitation.

Q.1.  I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system?

A.1. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation,  and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 – 200) ppb.

Q.2. What types of samples will be tested?

A.2. This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases.

Q.3. What specific substances or compounds need to be detected or analyzed in these samples?

If available, please also share any specific testing standards or requirements. With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly.

A.3. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation,  and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector.

For improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts.  

Q.4. Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)? 

A.4. The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel.

There is not an extension to the solicitation as a result of this amendment.

The question period for this soliciation will close today, September 17,2026, at 4:00 PM ET.

End of Amendment 0001

********

See attached.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
M7DHRHBB8GM8
CAGE
70NJ3
Vendor location
Katy, TX
Contract
1333ND26PNB640652, purchase order
Obligated
$85,863.00
Actions
1 between September 23, 2026 and September 23, 2026
Competition
Competed Under SAP, 3 offers received
Set-aside reported
Small Business Set Aside - Total
Described as
Ou63-Fy26-205-New - Gas Chromatograph with TCD and Fid-Methanation Detectors.
Match
solicitation number 1333ND26QNB640601 equals the FPDS solicitation identifier; same awarding office 1333ND (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. September 15, 2026

    Solicitation

    Due September 21, 2026 at 12:00 PM EDT. SAM.gov, notice a31c5d87fbd7421fa2623257931cec77

    1 revisions on SAM
    • September 15, 2026: publish, solicitation
  2. September 17, 2026

    Solicitation

    Due September 21, 2026 at 12:00 PM EDT. SAM.gov, notice c3d1218425364835b7b429d402a51245

    2 revisions on SAM
    • September 17, 2026: publish, solicitation
    • September 15, 2026: publish, solicitation

Points of contact