Sources sought
AvaSure
W81K00-25-Q-A020
Department of the Army, W40M MRC0 West. Security Systems Services (except Locksmiths).
Response deadline
February 14, 2025 at 11:00 AM EST
Closed 581 days ago. Posted February 3, 2025. Scheduled to archive March 1, 2025.
Description
As published on SAM.gov.
The Medical Readiness Contracting Officer- W (MRCO-W) is issuing this Sources Sought Notice on behalf of Brooke Army Medical Center to find potential sources to provide a AvaSure Monitor cameras software update. THIS IS NOT A SOLICITATION ANNOUNCEMENT – This is a Sources Sought Notice and is issued solely for information and planning purposes – it does not constitute a Request for Quote (RFQ) or a promise to issue an RFQ in the future.
Solicitations are not available at this time and requests for a solicitation will not receive a response. This notice does not constitute a commitment by the United States Government to contract for any supply or service whatsoever. All information submitted in response to this announcement is voluntary; the United States Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the United States Government.
Not responding to this Sources Sought Notice does not preclude participation in any future Request for Quote (RFQ), should one be issued. It is the responsibility of the potential offerors to monitor this site for additional information pertaining to this requirement. The Government will use responses to this notice in formulating its acquisition strategy.
If the Government does not receive sufficient information in response to this notice to verify the potential for competition exists, it is possible that a sole-source contract, supported by a Justification and Approval document, will be issued to support the Government's requirement.
MRCO-W is seeking the following information (please answer paragraphs below with your response): Company name, Unique Entity ID, CAGE code, and point of contact information (including phone number and email address), and socio-economic category(ies) as related to 561621 – Security Systems Services (except Locksmiths), such as 8(a), HUBZone, Women-Owned, Service-Disabled Veteran-Owned, Small, or Other-than-Small.
Capability Statement (limited to ten pages), describing how your company meets the below objectives additional proof (such as product literature and locations where a system is currently installed) where appropriate: Monitoring cameras, observation monitoring equipment with software that meet the below required characteristics: - The system must offer multiple device configurations including mobile devices that can be moved to patient rooms as needed (i.e.., mobile) and permanently mounted devices (i.e., fixed).
Mobile unit must be capable of locking into place when needed (e.g., via casters). All devices must have the same functionality and be able to work together within the facility. Simultaneously, the system must be Health Insurance Portability and Accountability Act (HIPAA) compliant. - The system’s individual device must provide 360-degree pan-tilt-zoom camera with 180-degree tilt and significant optical zoom so that monitor is able to see entirety of patient room to notice if there is a change in patient condition.
The devices must be able to function in complete dark but not interfere with other equipment in the patient room. Screen resolution of at least 720p. - The system must provide an immediate alarm function that is used by monitor staff for alerting floor staff of imminent danger and/or if a patient is not responding to voice commands and is at high risk for an adverse event. This “STAT” alarm must be distinct and only activated when there is a verified event.
Automated warnings must be available in English and Spanish. - The system must be compliant with Federal Information Processing Standards (FIPS) and compatible with Defense Health Agency requirements for such systems.
Company must be able to perform software support through updates, upgrades, patches, and other technical support. - Company must provide a single point of contact (e.g., Program Manager) to shepherd project from award through installation to training of hospital staff on the floor and in Biomedical Maintenance.
The response due date for this Sources Sought Notice is 10:00 AM CST, 14 February 2025. All questions and comments regarding this announcement shall be submitted via e-mail to the below POCs: yakita.s.mcclurkin.civ@health.mil
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
February 3, 2025
Sources sought
Due February 14, 2025 at 11:00 AM EST. SAM.gov, notice 0a960ca41adf4cf7812acc60d9ab978a
Points of contact
- YaKita McClurkinyakita.s.mcclurkin.civ@health.mil2105398425
Also open from this buyer
- Microbiology testing Kits and Consumables-Requirement is for consumables and kits are for pathogen detection.SolicitationNAICS 334516W81K0026QA274Closes in 3 daysSep 21
- EMS Mobile ApplicationCombined synopsis and solicitationSmall businessNAICS 513210TexasW81K0026QA277Closes in 4 daysSep 22
- Holistic Health and Fitness (H2F) Performance Team (HPT) servicesPresolicitationSmall businessNAICS 621340W81K0027RA002Closes in 12 daysSep 30
- Emergency Aeromedical Evacuation ServicesCombined synopsis and solicitationSmall businessNAICS 481211W81K0026QA240Closes in 13 daysOct 1
- Ground Ambulance Services at Ft. Polk, LASolicitationNAICS 621910LouisianaW81K00-26-R-A051Closes in 33 daysOct 21