Combined synopsis and solicitation, total small business set-aside
IDA LEWIS Watertight Doors/Hatch/Scutt
70Z085Q250012029
US Coast Guard, SFLC Procurement Branch 2. Ship Building and Repairing.
Response deadline
April 3, 2025 at 11:00 AM EDT
Closed 533 days ago. Posted March 26, 2025, first published March 25, 2025. Scheduled to archive April 3, 2025.
Description
As published on SAM.gov.
THIS IS TO BE AWARDED BASED OFF LOWEST PRICE TECHNICALLY ACCEPTABLE AND PAST PREFORMANCE.
USCGC IDA LEWIS (WLM 551) SPECIFICATION FOR FABRICATION OF WATERTIGHT AND NON-WATERTIGHT DOORS, HATCHES, AND SCUTTLES FY2025 Developed By: Jason W. Taylor (Rev-0, 05 March 2025) TABLE OF CONTENTS Revisions Record. iii Consolidated List of References. iv WORK ITEM 1: Fabrication of Water Tight and Non Water Tight Doors, Hatches, and Scuttles 5 Revisions Record This page is used to record specification revisions, which may have occurred subsequent to a Revision 0 (Rev-0) package.
Information listed is intended to provide contractors and field unit personnel a means to ensure all the current specification revision pages are present when reviewing or utilizing this specification package.
DATE REV# WORK ITEM# CHANGES MADE NOTE: All work item and paragraph numbers listed above for a given revision correspond to same numbers in the previous revision. This revised specification is self-contained with all of the above listed changes incorporated. Consolidated List of References The below-listed documents form a part of this specification to the extent specified herein.
Approval/publication dates or revision dates/numbers are also identified, to ensure that same document versions are used at the time of specification writing and during contract execution. All Coast guard drawings, technical publications, and standard specifications will be provided to contractors by the Coast Guard at an appropriate time, or upon request, free of charge. Other Government documents may be accessed – free of charge – from links located on the SFLC website.
Commercial sites provide access to their respective documents.
COAST GUARD DRAWINGS Coast Guard Drawing 175-WLM 167-001, Rev L, 2014, Structural Closures Coast Guard Drawing 175-WLM-624-001, Rev F, 1998, Joiner Door Schedule Coast Guard Drawing 175-WLM-631-002, Rev E, 2000, Paint Schedule COAST GUARD PUBLICATIONS Coast Guard Commandant Instruction (COMDTINST) M10360.3, Jun 2006, Coatings and Colors Manual Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures OTHER REFERENCES Code of Federal Regulations (CFR) Title 29, Part 1915, Occupational Safety and Health Standards for Shipyard Employment Commercial Item Description (CID) A-A-59316, 2016, Abrasive Materials; for Blasting Military Specification MIL-A-22262B, March 1996, Abrasive Blasting Media Ship Hull Blast Cleaning NAVSEA Technical Publication T9074-AD-GIB-010/1688, (TP 1688), July 2012, Requirements for Fabrication, Welding, and Inspection of Submarine Structure The Society for Protective Coatings (SSPC) Surface Preparation Standard No. 11 (SSPC-SP 11), 2013, Power-Tool Cleaning to Bare Metal The Society for Protective Coatings (SSPC)/NACE International (NACE) 2007, Joint Surface Preparation Standard SSPC-SP 10/NACE No. 2, Near-White Metal Blast Cleaning ITEM 1: Fabrication of Watertight and Non-Watertight Doors, Hatches, and Scuttles 1. SCOPE 1.1 Intent.
This work item describes the requirements for the Contractor to fabricate watertight and non-water tight doors, hatches, and scuttles identified in Table 1 in accordance with drawings and references. Table 1 - Watertight Doors and Scuttle locations Description Location P/N and Description QTY Drawing Watertight Scuttle Main Deck (1-20-2)
PN: 7 21-inch Diameter Quick-Acting Watertight Flush Scuttle, Steel, 3-Dog, Fwd Hinge (including associated 12” height coaming) hasp and staple. 01 Each 175-WLM 167-001 Watertight Hatch Main Deck (1-50-1)
PN: 6 QAWTH 1-5-0; 30” x 30” Quick-Acting Watertight Hatch, Steel, (Raised 12-inch coaming, 21” QAWTS (hinge fwd.)), including 12-inch height coaming. 01 Each 175-WLM 167-001 Watertight Door ATON Shop (1-10-0-Q)
PN: 11 26” x 66” C.O., WT, QA, LH, 10-Dog W/ HASP and Staple, W/O Fixed Light Low Type Cres Hinges. Steel. 01 Each 175-WLM 167-001 Watertight Door Passageway Main Deck (1-52-0-L)
PN: 18 Door – 30” x 66” C.O., WT, QA, RH, 10 Dog w/ Hasp and Staple w/ Fixed Light Low Type Cres Hinges, Steel. 01 Each 175-WLM 167-001 Watertight Scuttle Line Locker (1-0-0-Q)
PN: 9 Scuttle – 18” Dia. C.O., RSD, QA, WT, w/ internal toggle pin lock on scuttle, steel, coaming 12” height. 01 Each 175-WLM 167-001 Joiner Door Boatswains Storeroom (1-6-0-Q)
PN: 02 Door, Joiner, steel, 26 x 76 ½”, 1 ½” coaming height, LH, INBD, w/ window and kickout. PNL Req’d. 01 Each 175-WLM-624-001 Joiner Door Paint Locker (1-9-2-K)
PN: 08 Door, Joiner, steel, 26 x 76 ½”. 1 ½” coaming height, RH, FWD, Fumetight window & kick-out panel REQ’d. LOC 4” FWD FR 13. 01 Each 175-WLM-624-001 Weathertight Door PFD Locker (Starboard) (02-61-1-Q)
PN: 16 Door, 26” x 66” C.O., Weat, RH, w/ hasp and staple, w/o fixed light, steel.
01 Each 175-WLM 167-001 1.2 Government-furnished property None 2. REFERENCES Coast Guard Drawings Coast Guard Drawing 175-WLM 167-001, Rev L, 2014, Structural Closures Coast Guard Drawing 175-WLM-624-001, Rev F, 1998, Joiner Door Schedule Coast Guard Drawing 175-WLM-631-002, Rev E, 2000, Paint Schedule Coast Guard Publications Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures Other References Commercial Item Description (CID) A-A-59316, 2016, Abrasive Materials; for Blasting Military Specification MIL-A-22262B, March 1996, Abrasive Blasting Media Ship Hull Blast Cleaning The Society for Protective Coatings (SSPC)/NACE International (NACE) 2007, Joint Surface Preparation Standard SSPC-SP 10/NACE No. 2, Near-White Metal Blast Cleaning The Society for Protective Coatings (SSPC) Surface Preparation Standard No. 11 (SSPC-SP 11), 2013, Power-Tool Cleaning to Bare Metal 3. REQUIREMENTS 3.1 General.
3.1.1 CIR. None. 3.1.2 Tech Rep. Not applicable. 3.1.3 Protective measures. Not Applicable 3.1.4 Interferences. Not Applicable 3.1.5 Testing. All testing to be completed in accordance with drawings and Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes 3.1.6 Shipping.
Contractor shall construct container to ship doors and hatches and must include pricing for shipping to CGC IDA LEWIS, CO CWO Michael Scalia, Surface Forces Logistics Command, 2401 Hawkins Point Road, Baltimore, MD, 21226-1797, Building 58. 4. NOTES None
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- GEORGE, JERAMYAHJERAMYAH.W.GEORGE@USCG.MIL5104375436
- DONNA O'NEALDonna.J.O'Neal@uscg.mil5103931145
Also open from this buyer
- CGC OAK WATER TIGHT DOORS, HATCHES, SCUTTLES RENEWALCombined synopsis and solicitationSmall businessNAICS 332321Newport, RI70Z08526Q0027652Closes todaySep 18
- USCGC POLAR STAR MOBILE DTECombined synopsis and solicitationSmall businessNAICS 424720Seattle, WA14501_MOBILE_DTE_FY26Closes tomorrowSep 19
- Heater ElectricSolicitationSmall businessNAICS 333414Maryland70Z08526Q30113B00Closes tomorrowSep 19
- Open, Inspect, Repair Cylinder Assy.Combined synopsis and solicitationSmall businessNAICS 81131070Z08526P49025B00Closes in 3 daysSep 21
- USCGC Stratton Shaft Alignment and Bearing Reaction CheckCombined synopsis and solicitationSmall businessNAICS 811310Alameda, CA70Z08526Q0026058Closes in 3 daysSep 21