Sources sought
Inspector Scopes
36C25524Q0498
Department of Veterans Affairs, 255-Network Contract Office 15. Surgical and Medical Instrument Manufacturing.
Response deadline
July 29, 2024 at 1:00 PM EDT
Closed 780 days ago. Posted July 22, 2024. Scheduled to archive August 13, 2024.
Description
As published on SAM.gov.
Statement of Work HealthMark Inspection Scope General Description of Performance Requirements and Features of the System: The Healthmark Inspection Scope is designed to visually inspect internal channels of potentially soiled or damaged items, provides enhanced light, vision, and magnification. The borescope also offers users the option to document photos and videos of lumens and crevices not visible to the unaided eye.
It has a modular design with interchangeable flexible inspection scope attachments available in diameters of 1.06mm and 1.9mm. These scopes have a working length of 110cm and attach to a 13.3W x 9.9L x 4.7H cm control box, allowing for light level adjustments, image capture*, and video recording*.
The 1.06mm scope is designed to inspect internal channels of 1.1mm in diameter or larger, and the 1.9mm scope is designed to inspect internal channels of 2.0mm in diameter or larger. *These features are only available for the USB control box with FIS-007 software, which is included and installs on Windows 10 PC’s This solicitation uses a Brand Name of the product required. The Eastern Kansas Health Care System requests to purchase Healthmark Digital Inspection Scope.
Each time a medical device is processed, it should be visually inspected for cleanliness and integrity. Enhanced inspection with magnification, borescopes, or other inspection methods to verify cleanliness and integrity may be used. Borescopes or other methods may be used to check internal channels of instrumentation for cleanliness and integrity unless otherwise recommended in the instrument manufacturer’s written IFU and the borescope manufacturer’s written IFU.
When recommended in the instrument manufacturer’s written IFU, enhanced inspection should be used and the enhanced visualization tool manufacturer’s written IFU should be followed. Healthcare facilities should have a method of ensuring cleanliness and integrity of every instrument and medical device used in every procedure. **Quote attached with packet: Quote denotes 2 eachcof each item but each campus is requesting only 1 each. The quote attached represents the total quantity needed and each campus.
Items Needed: FIS-007USK – USB Control Box Kit 2/1.9mm Catheter CT-102 – Catheter, 1.06 mm Dia 110 cm length, Flexible Inspection Scope FIS-007SPT – Storage & Protection Tray Requirements: Must comply with AAMI ST79 (2017)
Amendment 2: 8.2 Inspection of Instruments Each time a medical device is processed, it should be visually inspected for cleanliness and integrity. Enhanced inspection with magnification, borescopes, or other inspection methods to verify cleanliness and integrity may be used. Borescopes or other methods may be used to check internal channels of instrumentation for cleanliness and integrity unless otherwise recommended in the instrument manufacturer’s written IFU and the borescope manufacturer’s written IFU.
When recommended in the instrument manufacturer’s written IFU, enhanced inspection should be used and the enhanced visualization tool manufacturer’s written IFU should be followed. Healthcare facilities should have a method of ensuring cleanliness and integrity of every instrument and medical device used in every procedure. Must provide lighted magnification and be able to document photos and videos of lumens and crevices not visible to the unaided eye.
Must be able to inspect internal channels of 1.1mm in diameter and larger. Must be easily cleanable between uses. Must be compatible with Scope Viewer Software. Must be compatible with Windows 10 or higher.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 22, 2024
Sources sought
Due July 29, 2024 at 1:00 PM EDT. SAM.gov, notice 27ed3be926ad4f25aa39f2feba50b45d
Points of contact
- Jon LutmerJonathan.lutmer@va.gov4104463862
Also open from this buyer
- ROLLA PACKAGE 073 PT EQUIP/ COPresolicitationSDVOSBNAICS 33911236C25526Q0640Closes todaySep 17
- ME - TRANSFER SWITCH MAINT BASE PLUS 5 - CO (VA-26-00004264) 589-26-3-5329-0002PresolicitationSmall businessMissouri36C255-26-AP-0031Closes todaySep 17
- Telephone Operator Support Services l KCVA | Base plus four (4) option yearsSolicitationSDVOSBNAICS 561421Kansas City, MO36C25526Q0654Closes todaySep 17
- Telephone Operator Support Services l KCVA | Base plus four (4) option yearsPresolicitationSDVOSBNAICS 561421Missouri36C25526Q0654_1Closes todaySep 17
- Biomed Analyzers and TestersSources soughtNAICS 334516Columbia, MO36C25526Q0661Closes todaySep 17