Notice of Intent to Sole Source - Emergency Repair of Philips DigitalDiagnost C90 High Performance X-Ray System - White River Junction VA Medical Center

36C24126Q0149

Department of Veterans Affairs, 241-Network Contract Office 01. Electronic and Precision Equipment Repair and Maintenance.

Awarded

Philips North America LLC

$61,582.50 obligated so far on USAspending

Description

As published on SAM.gov.

This notice is issued in accordance with FAR 5.2 and serves as a notice of intent to award a sole-source contract. It is NOT a request for quotes. The Government may, at its discretion, consider responses to this notice. However, at this time, only one responsible source is currently identified as capable of meeting agency needs. The Department of Veterans Affairs, VISN 1, intends to award a Firm-Fixed-Price contract for the emergency repair of the Philips DigitalDiagnost C90 X-ray system located at the White River Junction VA Medical Center. The required services include:

Providing and replacing two (2) 3-Phase Inverter Boards Providing and replacing the High Voltage Generator Tank All work must be performed in accordance with Philips Medical Standards, including functional testing and calibration to ensure compliance with Philips specifications.

Justification for Sole Source: Philips is the original manufacturer and developer of the DigitalDiagnost C90 system and is the only vendor with the proprietary knowledge, parts, and technical capability to perform these repairs at the required level of quality and reliability. Due to the specialized and proprietary nature of this equipment, Philips has been determined to be the sole source vendor for this requirement. Schedule of services: Item # Description Quantity 0001 Emergency Repair of Philips DigitalDiagnost C90 High Performance X-Ray System. Price Include the following:

*3 Phase Inverter Boards x 2 PCE *EPS ETA 80R(kW) HV Generator x 1 PCE *Travel & Onsite Repairs 1 ea Service Location: White River Junction VAMC 215 North Main Street White River Junction, VT 05009-0001 The period of performance has not yet been determined; specific dates will be finalized prior to contract award. Interested parties may submit a response demonstrating their capability to meet the requirements outlined in this notice by the due date specified.

Responses should include sufficient evidence to show that competition would be advantageous to the Government. Information received will be used solely to determine whether a competitive procurement is appropriate. The Government reserves the right to make this determination at its sole discretion. No reimbursement will be provided for any costs incurred in preparing or submitting a response. Refer to the attached Statement of Work for a complete description of the required services.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
T41NB3MDAPZ6
CAGE
8HEG5
Vendor location
Bothell, WA
Contract
36C24126P0154, purchase order
Obligated
$61,582.50
Actions
2 between December 30, 2025 and April 27, 2026
Competition
Not Competed, 1 offer received
Set-aside reported
No Set Aside Used.
Described as
Xray Repair
Match
solicitation number 36C24126Q0149 equals the FPDS solicitation identifier; same awarding office 36C241 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. December 22, 2025

    Special notice

    Due December 26, 2025 at 3:00 PM EST. SAM.gov, notice 1f97beb46189443ca75629aa8ebd2d5f

  2. December 23, 2025

    Special notice

    Due December 26, 2025 at 3:00 PM EST. SAM.gov, notice a772845db9614628b23203fb34d6817a

Points of contact