Combined synopsis and solicitation, total small business set-aside
Bridge Crane Aux. Hoist Variable Frequency Drive Repair
W9127N24Q0140
Department of the Army, W071 Endist Portland. Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance.
Response deadline
September 3, 2024 at 2:00 PM EDT
Closed 745 days ago. Posted August 23, 2024, first published August 16, 2024. Scheduled to archive September 18, 2024.
Description
As published on SAM.gov.
Solicitation W9127N24Q0140 is for repair of one (1) Variable Frequency Drive (VFD). VFD requiring repair is utilized in John Day Dam’s Bridge Crane, Auxiliary Hoist. See attachment for details.
QUESTIONS & ANSWERS: 1. (Q) Are you able to share any information on what is wrong with the drive? 1. (A) The bridge crane VFD started exhibiting unstable voltage output. Input voltage was stable. We believe the possible causes to be Faulty Capacitors, Internal Power Supply Modules, AND/OR Control board or microprocessor.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Meagan Moralezmeagan.n.moralez@usace.army.mil5038085017
Also open from this buyer
- John Day Dam Fish Pump Rehabilitation ProjectSolicitationSmall businessNAICS 237990Rufus, ORW9127N26BA031Closes tomorrowSep 19
- Purchase of Straval Valves for The Dalles Lock & Dam USACESolicitationNAICS 332911W9127N26QA164Closes tomorrowSep 19
- Lookout Point DGA supply and incidental installSolicitationSmall businessNAICS 334513Jacksonville, ORW9127N26QA160Closes in 3 daysSep 21
- Blanket Purchase Agreement - Sample TestingCombined synopsis and solicitationSmall businessNAICS 541380Portland, ORW9127N26QA092Closes in 7 daysSep 25
- W9127N26QA145 - PH2 BLADE SEALS REPLACEMENT for Bonneville DamSolicitationNAICS 339991OregonW9127N26QA145Closes in 8 daysSep 26