Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform.
The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample.
Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes.
Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds.
Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states.Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
January 14, 2026
Combined synopsis and solicitation
Due January 30, 2026. SAM.gov, notice 103641ae64874cfe8be78200849a8a39
Points of contact
- Carl Lundellcarl.lundell@westpoint.edu571.748.9816
Also open from this buyer
- Rivage PM5 PackageCombined synopsis and solicitationSmall businessNAICS 334310W911S226U4476Closes todaySep 18
- Camera EquipmentCombined synopsis and solicitationSmall businessNAICS 334310W911S226U3988Closes todaySep 18
- Mesh Task ChairsCombined synopsis and solicitationSmall businessNAICS 337214W911S226U4485Closes todaySep 18
- Exercise EquipmentCombined synopsis and solicitationSmall businessNAICS 339999W911S226U4465Closes todaySep 18
- Out Door Freezer UnitCombined synopsis and solicitationSmall businessNAICS 333241W911S226U4489Closes todaySep 18