Combined synopsis and solicitation, total small business set-aside
Prefabricated Timber Crossing Panels
W911S225U0867
Department of the Army, W6QM Micc-Ft Drum. All Other Transportation Equipment Manufacturing.
Response deadline
June 11, 2025 at 3:00 PM EDT
Closed 464 days ago. Posted June 5, 2025, first published June 4, 2025. Scheduled to archive June 5, 2026.
Description
As published on SAM.gov.
Amendment to add Set Aside Code from N/A to Total Small Business Set-Aside. Overview:Request is for Prefabricated Timber Crossing Panels. The timber panels layover the rail and ties to allow passenger vehicles cross.
The panels are generally 8 feet in length and require detailed cuts, notching, beveling, and drilling to perfectly fit inside the rail gauge and outside on the rail field side.Requirement:Requesting quote for timber crossing panels to repair/replace the existing panels for eleven (11), standard rail gauge, crossings. Each crossing is comprised of eight (8) panels, 8-ft panel sections (gauge and field panels) for a total of 704 track feet of grade crossings.
Total Panels Required = 88 Pannels (11 Crossings x 8 Panels per crossing).Panels Length = 8 ft sections (gauge and field panels).Total Track Feet = 704 ftPanels SHALL be Full depth creosote-treated hardwood timber crossing panels for railroad crossings.Timbers SHALL be primarily oak and with some mixed hardwoods allowed.Panels must be fit for 100-lb AREA rail placed on 10-ft cross-ties.The panels SHALL NOT be pre-drilled for fasteners, and no fasteners required.The standard creosote retention for railroad timbers is 7 pounds per cubic foot (pcf) for oak, hickory, or mixed hardwoods. Creosote is required for protection against decay fungi and insects, and restores the woods natural elasticity.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Kevin Harpkevin.m.harp.civ@army.mil5716448800
- Joy Davisjoy.l.davis18.civ@army.mil3157725582
Also open from this buyer
- Exercise EquipmentCombined synopsis and solicitationSmall businessNAICS 339999W911S226U4465Closes todaySep 18
- Out Door Freezer UnitCombined synopsis and solicitationSmall businessNAICS 333241W911S226U4489Closes todaySep 18
- OFFICE CHAIRCombined synopsis and solicitationSmall businessNAICS 337214W911S226U4432Closes todaySep 18
- ZOLL AED DefibrillatorsCombined synopsis and solicitationSmall businessNAICS 334510W911S226U4425Closes todaySep 18
- Physical Fitness PlatformCombined synopsis and solicitationSmall businessNAICS 332312W911S226U4504Closes todaySep 18