Hydrostatic Test Stand

SP470624Q0029

Defense Logistics Agency, Dcso-Columbus-Division-2. Analytical Laboratory Instrument Manufacturing.

Awarded

Barbee Valve & Supply Inc.

$56,100.00 obligated so far on USAspending

Description

As published on SAM.gov.

Hydrostatic Test Chamber – Commercial requirement to acquire a new Hydrostatic Test Stand capable of generating 20,000 pounds per square inch (PSI) of pressure to conduct Proof, Leakage, Burst and Electrical Conductivity testing of DLA’s Customer supplied products such as hoses and valves in support of the Warfighter efforts.

EMAIL QUOTES TO:

Elizabeth.Hanlon@dla.mil. Emailed quotes cannot exceed 15 MB. E-mailed quotes greater than 15 MB must be divided into multiple emails. Please return the attached solicitation completed along with your proposal.

General Requirements: Hydrostatic Test Unit must be new, not refurbished. Unit must have High and Low pressure, pneumatically driven pumps. Unit must have the ability to supply required pressures and hold indefinitely, as in no internal leakage or pressure loss to hoses, control valves, gages etc. Contractor is responsible for initial setup of test unit. Contractor is responsible for suppling operation and maintenance manuals. System must be “turnkey” after setup.

Contractor must supply all necessary connectors, hose, hardware, etc. On-site training (1 day) for 5 associates at DSCC, DLA Land and Maritime Product Test Center, Mechanical Lab, VTM, Columbus, OH to be included in purchase. Initial calibration to be included in purchase and certifications provided. Overall Pressure Measuring Parameters must be 0-20,000 psi. Must include a minimum of 5 different pressure gage ranges.

Anticipated gage ranges: 0-500, 0-1,000, 0-3,000, 0-10,000 and 0-20,000 pound per square inch (psi). 11. All gages must be digital if used as a standard or reference gage contributing to data collection. 12. All gages used in pressure generation or supply can be of analog type. 13. Accuracy of standard or reference gages must be 0.5% or better. 14. Overall unit dimensions cannot exceed 110” wide, 48” deep and 102” high. 15. Test chamber must have a protective and see through door/lid, illuminated and withstand testing pressures up to 20,000 psi.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
NUDWNKYYRBF9
CAGE
4M588
Vendor location
Reno, NV
Contract
SP470624P0020, purchase order
Obligated
$56,100.00
Actions
2 between August 22, 2024 and August 22, 2024
Competition
Competed Under SAP, 4 offers received
Set-aside reported
Small Business Set Aside - Total
Described as
Columbus Product Test Center (Ptc) Hydrostatic Test Stand
Match
solicitation number SP470624Q0029 equals the FPDS solicitation identifier; same awarding office SP4706 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 3, 2024

    Presolicitation

    Due August 6, 2024 at 3:00 PM EDT. SAM.gov, notice 5e0bd5620cbe46858b51c573fd84e794

  2. July 18, 2024

    Solicitation, originally presolicitation

    Due August 1, 2024 at 3:00 PM EDT. SAM.gov, notice 1bd09e5353cb47f3ac7e448729adb350

Points of contact