Combined synopsis and solicitation, service-disabled veteran-owned small business set-aside
Roll-Up Doors Replacement & Install
36C25024Q0457
Department of Veterans Affairs, 250-Network Contract Office 10. Metal Window and Door Manufacturing.
Response deadline
April 1, 2024 at 12:00 PM EDT
Closed 901 days ago. Posted March 21, 2024. Scheduled to archive April 12, 2024.
Description
As published on SAM.gov.
Statement Of Work Statement Of Work Replace Roll-Up Doors General: Provide material and labor to three roll-up doors. Located at 1481 W.10th Street Indianapolis, IN 46202. Conformance Standards: All services provided under this contract must be performed in conformance with the Occupational Safety and Health Administration (OSHA), and Original Equipment Manufacturer standards and specifications. Material provided shall be installed in accordance with the American National Standards Institute (ANSI).
Performance Requirement: Services shall be scheduled with the Electric Shop Supervisor Stephen Poynts.
Services Required: Contractor shall provide parts and labor to replace three roll-up doors. Door #3 Qty 1 - CHI 8 x 8 Rolling Fire Door for VA 165-degree fusible links provided (standard). Closing speed regulated by centrifugal or viscous governor. Closing speed to be between 6" to 24" per second per NFPA 80. Curtain slats and hood are hot-dipped galvanized, per ASTM A653 A, with baked on epoxy primer. Guides and headplates painted black. Bottom bars to be painted black.
Miller 2 wire reversing edge with single phase liftmaster firedoor operator UL / ULC 3 Hour Rated Fire Do Door #13 Qty 1 - CHI 8 x 9 Rolling Fire Door for VA 165-degree fusible links provided (standard). Closing speed regulated by centrifugal or viscous governor. Closing speed to be between 6" to 24" per second per NFPA 80. Curtain slats and hood are hot-dipped galvanized, per ASTM A653 A, with baked on epoxy primer. Guides and headplates painted black. Bottom bars to be painted black.
Miller 2 wire reversing edge with single phase liftmaster firedoor operator UL / ULC 3 Hour Rated Fire Do Warehouse Door Qty 3 - CHI 8 x 9 Insulated Rolling Steel Doors for Warehouse Replace existing warehouse doors with new CHI rolling steel doors turn Contractor Requirements: Contractor shall perform work in a professional manner and to the highest standards. Contractor shall check in with VAMC at time of arrival and checkout as defined in service hours.
Contractor to complete the VA Vendor Credentialing process and have all employees working on VA property badged with VA contractor badges through Police Services before beginning any work at the VA. All contractors shall always wear VA Contractor Badges while onsite. Contractor must be licensed/certified by the State of Indiana. Contractor shall be required to follow all ICRA requirements set forth by the infection control staff.
Contractor is responsible for coordinating all shutdowns with the VA and the VA Staff who will be affected by said shutdown and with the electric shop. The contractor may come to the electrical shop for guidance, but they are inherently responsible for the planning and implementation of said shutdown. Contractor is to remove all trash and debris at the completion of job. The work area is to always be kept clean.
The Contractor is to ensure that all tools, equipment, and material are kept and placed in an orderly fashion to have as little impact on daily operations to the hospital, staff, and patients. Contractor shall be required to complete a VAMC Indianapolis Service Ticket when the work is completed. Contractor shall perform a function test in the presence of a VA employee designated by the Electric shop supervisor.
Note: All work is expected to encounter normal conditions. Contractor to Install equipment in accordance with the manufacturers installation instructions. If anything, unusual is encountered the VA will be notified and pricing will adjust accordingly. Payment for services: Invoices will be paid in arrears monthly upon completion of the services. Each invoice must include VA purchase order number, and invoice number and the month of the service being invoiced. The invoice should be mailed to the address identified herein.
Security Requirements: The Contractor s employees shall wear visible identification and company uniforms, approved by the COR, at all times and while on the premises of the VA. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police Section or from the Contracting Officers Representative (COR). The VA will not validate or make reimbursement for parking violations of the Contractor under any conditions.
Smoking is prohibited inside any buildings at the VA. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
March 21, 2024
Combined synopsis and solicitation
Due April 1, 2024 at 12:00 PM EDT. SAM.gov, notice b027ecb0bc69451eb3c76144af852766
Points of contact
- Rhonda L Fitzgerald, Contracting Officerrhonda.fitzgerald@va.gov317-988-1844
Also open from this buyer
- 541-26-3-250-0496 - UltraSAFE Automatic Formalin Dispensing System This is a a Small Business Only Set-AsideCombined synopsis and solicitationSmall businessNAICS 333914Cleveland, OH36C25026Q1047Closes in 2 daysSep 21
- 3D Scanning Water SystemSolicitationNAICS 33451736C25026Q1043Closes in 2 daysSep 21
- Parking Garage Retractable Door ReplacementCombined synopsis and solicitationSDVOSBNAICS 812930Detroit, MI36C25026Q0979Closes in 3 daysSep 22
- Extend Due Date and Answer QuestionsCombined synopsis and solicitationSDVOSBNAICS 238220Fort Wayne, IN36C25026Q0927Closes in 3 daysSep 22
- HVAC Replacement ChillersCombined synopsis and solicitationNAICS 333415Chillicothe, OH36C25026Q0361Closes in 3 daysSep 22