Special notice, first published as sources sought
402-25-008 Repair Condensate Pump Room Roof
36C24125R0058
Department of Veterans Affairs, 241-Network Contract Office 01. Engineering Services.
Awarded
$72,778.06 obligated so far on USAspending
Description
As published on SAM.gov.
Request For Qualifications Statements (SF 330)
General Project Description:
Project Number:
402-25-008 Project Title: A-E Repair Condensate Pump Room Roof Location of Project: VA Maine Healthcare System (VAMC Togus), Augusta, Maine 04330 A/E Type A&B Services (also known as Design Phase) for this design project includes site visits, field investigation, studies and user interviews to prepare drawings, specifications and cost estimates for all facets of work and disciplines/trades to repair condensate pump room roof located on the Togus campus.
This project will repair the deteriorating condensate pump room roof in the basement of B201. The A/E must consider the need for all condensate pumps to remain operational during the construction period. This project will consist of concrete testing and design for temporary shoring, abatement (if required), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant.
The existing ceiling supports multiple pipes and electrical conduits, lights, etc. The design package should include detailed plans on how to temporarily support all existing utilities. If disconnection is required, the A/E must determine the source of energy, existing isolation locations, and impact to facility when isolated. The A/E is to provide a final load rating for the roof once repairs are complete.
The design will include drawings showing ICRA required construction barriers, properly sized negative air machines, as well as duct routing for exhausting air. Additionally, the A/E shall prepare all required National Environmental Policy Act (NEPA) analysis and Environmental Assessment reports and documentation for any improvements made as part of this project.
NAICS and Set-Aside Information: This procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has an SBA size standard of $25.5 million in average revenue. This procurement is a total set-aside for verified Small Businesses (SB).
Key Dates:
Period of Performance: 120 calendar days.
Questions Due:
06/06/2025 4:30 PM EST. SF 330 Package Due:
06/27/2025 4:30 PM EST. Instructions: See attached Request for Qualification Statement (SF330s) for submission requirements.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Harriman Associates
- UEI
- SFEFWZKEB7L7
- CAGE
- 0HW22
- Vendor location
- Auburn, ME
- Contract
- 36C24125C0083, definitive contract
- Obligated
- $72,778.06
- Actions
- 1 between September 26, 2025 and September 26, 2025
- Competition
- Full and Open Competition After Exclusion of Sources, 1 offer received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- A-E Repair Condensate Pump Room Roof- Type a Services
- Match
- solicitation number 36C24125R0058 equals the FPDS solicitation identifier; same awarding office 36C241 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Andrew Merical, Contract SpecialistAndrew.Merical@va.gov401-273-7100
Also open from this buyer
- VSCAN AIR CL and SL Portable Handheld Ultrasounds: INTENT TO SOLE SOURCE: SDVOSB Sole Source VAAR 819.7008/Brand Name FAR 12.102-1(a)PresolicitationSDVOSB sole sourceNAICS 334510Augusta, ME36C241Q0777Closes todaySep 18
- Sorna CD Burner Acquisition Modification P0003 Combined Synopsis: SD/VOSB Set-Aside/RFQ Extension to 09/18/26 at 11:00 AM EDT Review Request for Brand NameCombined synopsis and solicitationSDVOSBNAICS 33411836C24126Q0731Closes todaySep 18
- 608-26-4-4808-0202: Water Tower Inspection & Maintenance- Service Contract (VA-26-00079725)SolicitationSDVOSBNAICS 23711036C24126Q0704Closes todaySep 18
- Repair or Replace Switchgear 4A at VAMC Central Western MACombined synopsis and solicitationSmall businessNAICS 811310Massachusetts36C24126Q0814Closes todaySep 18
- Bulk Oxygen ContractCombined synopsis and solicitationSmall businessNAICS 325120White River Junction, VT36C24126Q0547Closes todaySep 18