As published on SAM.gov.
Request for Information: The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey. This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.
Requirement: Contractor shall furnish all materials, supplies, tools, equipment, transportation, supervision, quality control, and labor necessary to complete this Scope of Work, at the areas specified at Kentucky Lock and Dam, located in Livingston County Kentucky. All materials and workmanship will be manufactured and accomplished according to industry standards and specifications. The existing lift station contains two (2) grinder pumps. One of the existing pumps has been removed and replaced.
The removed pump shall be repaired to full functionality. The removed pump is a Zoeller Model G7112, 7.5 HP, 3450 RPM, 460/3/60 Hz, submersible high head grinder pump complete with 2 ½ inch horizontal discharge flange that is adaptable to 3-inch, SC/SC lower seal, 7.125-inch diameter impeller complete with 25-feet power & control cable. The contractor shall repair or replace the transducer associated with the lift station pump.
The currently installed transducer is precision digital PDA6420 Split Core AC Current Transducer. Correct the alignment of the pump 2 outlet with the pump 2 sewage pipe inlet. Currently, the items are misaligned, and a gap exists on one side of the connection. Costs estimated for this work shall include any pumping/removal of existing waste in the lift station that is required to complete this task safely.
Reference the provided reference document for additional details related to existing utilities associated with the lift station. The Contractor shall perform a functionality test to ensure the following functions work as intended by design: Both pumps automatically run via the transducer system. Both pumps automatically run via the float system. The pumps automatically switch from the transducer system to the float system if the transducer system fails.
Period of Performance: The Period of Performance shall be performed within 30 calendar days of the award date.
Place of Performance: Kentucky Lock Resident Office 193 Taylor Park Rd.
Grand Rivers, KY 42045 NAICS: The anticipated NAICS code for this requirement is 238210 (Electrical Contractors and Other Wiring Installation Contractors) with a size standard of $19,000,000.
Survey: Please send responses to the Market Survey to Samantha Clay at Samantha.J.Clay@usace.army.mil by 12:00PM CT on October 23, 2025. Name of Firm:
CAGE: Point of Contact (include email address) Are you classified as a small business under any of the following NAICS code: 238210 (Electrical Contractors and Other Wiring Installation Contractors) 5. If this requirement is advertised, do you anticipate submitting a quote? 6. List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience with electrical and wiring installation:
1. Project Name / General Description: Contract Number (if applicable):
Dollar Amount:
2. Project Name / General Description: Contract Number (if applicable):
Dollar Amount:
3. Project Name / General Description: Contract Number (if applicable):
Dollar Amount:
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
October 16, 2025
Sources sought
Due October 23, 2025 at 1:00 PM EDT. SAM.gov, notice c0519d714d0d400190dc30b32780645a
Points of contact
- Samantha Claysamantha.j.clay@usace.army.mil6153300089
- Cierra Vegacierra.r.vega@usace.army.mil6157367976
Also open from this buyer
- Dale Hollow - Powerhouse Doors CoatingSolicitationSDVOSBNAICS 238320Celina, TNW912P526QA047Closes in 3 daysSep 21
- Transformer Relocation at Kentucky LockCombined synopsis and solicitationSmall businessNAICS 237130W912P526QA050Closes in 3 daysSep 21
- Cordell Hull - BC Battery ReplacementSolicitationSmall businessNAICS 335910Carthage, TNW912P526QA051Closes in 5 daysSep 23
- Center Hill - Vacuum Circuit BreakerSolicitationSmall businessNAICS 335313TennesseeW912P526QA048Closes in 5 daysSep 23
- Performance Oriented Construction Activity (POCA) for Nashville DistrictSources soughtNAICS 238990Nashville-Davidson, TNW912P526AAJJCloses in 13 daysOct 1