Skip to content
Abierto

Presolicitation, partial small business set-aside

United States Army CORPS of Engineers, Savannah District, Environmental Laboratory Requirements

W912HN24R1005

Department of the Army, W074 Endist Savannah. Testing Laboratories and Services.

Response deadline

August 30, 2024 at 2:00 PM EDT

Closed 749 days ago. Posted July 26, 2024. Scheduled to archive September 14, 2024.

Description

As published on SAM.gov.

The Savannah District, USACE, intends to issue solicitiations directly to six (6) laboratories that hold certifications for DOD ELAP, NC DEQ, SC DHEC, FL-NELAP, and GA. This requirement is to establish blanket purchase agreements (BPA), with a target of two laboratories, for environmental analytical and laboratory services. The resulting BPAs will be awarded to one (1) Large Business, and one (1) small business.

Proceedures used will be FAR Part 12 (Commercial Items) and FAR Part 13 (Simplified Aquisition Proceedures). The primary objective of this requirement is to provide laboratory analysis of aqueous and soil samples using laboratories that are NELAP certified for all states within the Savannah District AOR which includes Alabama, Florida, Georgia, South Carolina, and North Carolina. Laboratory must hold NELAP certification approved by each State for all EPA Methods listed the scope of work.

Certificates must be provided. Provide the analysis of groundwater samples as outlined in the attached tables. Laboratory must provide the technical manager with a list of the detection limits (DL) or method detection limits (MDL), limits of detection (LOD), and limits of quantitation (LOQ) for all methods and analytes listed in attached tables for groundwater matrices in order to be considered.

Laboratory must show that any LOQ is below the 15A NCAC 02L.0202 (2L) Groundwater Quality Standards (https://files.nc.gov/ncdeq/documents/files/15a%20ncac%2002l%20.0202.pdf). If no regulatory value exists under the 2L, please use the EPA Maximum Contaminant Level for all methods listed in the attached tables for drinking water or EPA Regional Screening Levels for Resident Tap Water (THQ=0.1). If no regulatory value exists for an analyte or method in aqueous matrices, the lab may use in-house standards.

If the required LOQ is not commercially available, the lab may use in-house standards. Laboratory must provide analytical results for the methods outlined in the tables in the scope of work and in accordance with each method’s respective table in appendix B of the DoD/DoE Consolidated Quality Systems Manual (QSM) for Environmental Laboratories v6.0 (or newer) and the certified and approved eQAPP.

Laboratory or any subcontracted laboratory must meet all LCS, MS, and surrogate recovery requirements as defined by Appendix C of the DoD/DoE Consolidated Quality Systems Manual (QSM) for Environmental Laboratories v6.0 for all methods listed in the attached tables. For any analyte or surrogate not listed in Appendix C of the QSM v6.0 or newest version, the laboratory may use in-house acceptance criteria. Deliverables include pre-printed bottle labels, written reports, shipment of bottles/coolers, and electronic data deliverables.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 26, 2024

    Presolicitation

    Due August 30, 2024 at 2:00 PM EDT. SAM.gov, notice 2eb880f3c7034a2fa4126c259af87ca9

Points of contact