Skip to content
Abierto

Combined synopsis and solicitation, total small business set-aside

Liquid Chromatography Mass Spectrometer

W911S226U3135

Department of the Army, W6QM Micc-Ft Drum. Analytical Laboratory Instrument Manufacturing.

Response deadline

May 15, 2026 at 12:00 PM EDT

Closed 126 days ago. Posted April 30, 2026. Scheduled to archive April 30, 2026.

Description

As published on SAM.gov.

Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform.

The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample.

Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes.

Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds.

Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states. Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.According to DFARS 204.7304 Solicitation provision and contract clauses (c) This is a COTS item and 252.204-7012 would be exempted from this solicitation - this item does not need to be CMMC 2.0 compliant.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. April 30, 2026

    Combined synopsis and solicitation

    Due May 15, 2026 at 12:00 PM EDT. SAM.gov, notice f8964e7c428943938b13869188725a7f

Points of contact

  • Camera Equipment
    Combined synopsis and solicitationSmall businessNAICS 334310W911S226U3988
    Closes todaySep 18
  • Mesh Task Chairs
    Combined synopsis and solicitationSmall businessNAICS 337214W911S226U4485
    Closes todaySep 18
  • Exercise Equipment
    Combined synopsis and solicitationSmall businessNAICS 339999W911S226U4465
    Closes todaySep 18
  • Out Door Freezer Unit
    Combined synopsis and solicitationSmall businessNAICS 333241W911S226U4489
    Closes todaySep 18
  • OFFICE CHAIR
    Combined synopsis and solicitationSmall businessNAICS 337214W911S226U4432
    Closes todaySep 18