Sources sought, total small business set-aside
High Pressure Boiler Inspections
W911N225RSS13
Department of the Army, W6QK Lad Contr Off. Plumbing, Heating, and Air-Conditioning Contractors.
Response deadline
June 13, 2025 at 4:00 PM EDT
Closed 462 days ago. Posted June 3, 2025. Scheduled to archive June 28, 2025.
Description
As published on SAM.gov.
The Army Contracting Command – Letterkenny Contracting Office (CCAM-DSL) is issuing this Sources Sought/Request for Information as a means of conducting market research to identify parties having an interest in providing all personnel, equipment, tools, materials, supervision, quality control and other items and nonpersonal services necessary to perform safety inspections to the High-Pressure Boilers to include internal and external inspection of Government owned boiler systems located at Letterkenny Army Depot (LEAD) for the Directorate of Public Works (DPW).
Contractor shall provide two annual inspections, an Annual Internal/External Inspection Without Steam and an Annual External Inspection Under Steam. All inspections shall include inspections to describe condition of soot, corrosion, scale, oil, erosion, grooving, bulging, warping, or cracking and state if active or inactive, describe condition of seams, refractory, baffles, tubes, tube ends, pipe connections, rivets or stays.
Describe condition of boiler setting, supports, seams, pipe connections, location of any corrosion, leakage, overheating or soot. Please see attached file "Sources Sought High Pressure Boiler Inspections" for more information.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 3, 2025
Sources sought
Due June 13, 2025 at 4:00 PM EDT. SAM.gov, notice 02bce6a8dd744ec78a028bc138fbbdeb
Points of contact
- Brian Creanbrian.c.crean.civ@army.mil7172675120
Also open from this buyer
- Rocket Motor Inspection System (RMIS) CABINET X RAY MACHINE SERVICECombined synopsis and solicitationSmall businessNAICS 541380Chambersburg, PAW911N226QA061Closes todaySep 18
- Water Blast System Service, Repair, & TrainingCombined synopsis and solicitationNAICS 811310Chambersburg, PAW911N2-26-Q-A011Closes in 3 daysSep 21
- ADAPTER, ELECTRICAL CONDUIT,Combined synopsis and solicitationSmall businessNAICS 335999Chambersburg, PAW911N2-26-Q-A068Closes in 3 daysSep 21
- Radiographic Testing (RT) of a large aluminum weldmentSources soughtNAICS 541380Chambersburg, PAW911N226QA069Closes in 11 daysSep 29
- Cleaning and Impregnation of CLET Heat ExchangersCombined synopsis and solicitationSmall businessNAICS 332813W911N226QA066Closes in 21 daysOct 9