Presolicitation
Philips Healthcare Physiological Monitoring Hardware and Software maintenance (Notice of Intent to sole source)
NOI-CC-25-005233
National Institutes of Health, National Institutes of Health - CC. Electronic and Precision Equipment Repair and Maintenance.
Awarded
$176,864.57 obligated so far on USAspending
Description
As published on SAM.gov.
Acquisition Description: This is a Notice of Intent, not a request for proposal.
The National Institute of Health, Clinical Center (NIH-CC) intends to negotiate on an other than full and open competition basis with Philip North America LLC (aka Philip Healthcare) The National Institute of Health Clinical Center standardized its systems to the Philips IntelliVue physiological monitoring system together with one line of interchangeable monitoring supplies with the activation of the Mark O. Hatfield Clinical Research Center (CRC) in 2005. The Philips IntelliVue operating system was upgraded in 2012 and again in 2021, using established licenses purchased during CRC activation.
These systems include monitoring and telemetry where patients are seen and require physiological monitoring i.e., Surgery, Radiology, Radiation Oncology, Clinics, Day Hospitals, Patient Care Units.
More specifically, the Philips IntelliVue monitoring system using PIIC iX REV C is used on 7SWS Metabolic, 5SE Telemetry, 3NW Oncology, 1NW Pediatric, 3NE Oncology inpatient care units, 3SW Intensive care unit, 5NW Medical Services, 7SWN Neuro, 3SWN Intermediate Care, 3SWN Procedure Vascular Conscious Sedation, Interventional Radiology, Department of Perioperative Medicine Post-Anesthesia Care Unit, and in all Operating Rooms.
The uniformity of the system allows Nursing to use one flow sheet for electronic medical records and allows for seem less IT interfaces, whether using Health Level 7 for Clinical Research Information System or RS232 Serial for Perioperative information system. The Philips IntelliVue physiological monitoring system has a CC-Wide Philips 1.4GHZ Wireless Medical Telemetry System.
The system includes CareEvent software that pushes waveforms and alarms to clinician's mobile phones and Vital Signs wireless interface to CRIS. The purpose of this requirement is to support the CC-Wide Philips physiological monitoring systems with hardware and software maintenance and updates.
Justification: The Clinical Center currently uses Philips proprietary systems for CC Wide patient monitoring.
The system includes approximately one hundred thousand sq. ft. of wireless medical telemetry coverage, Clinical Research Information System (CRIS) and Perioperative Information System (POIS) interfaces, CareEvent interface where remote waveforms and alarms are pushed to clinical staff’s mobile phones, remote diagnostics, and Philips Incenter web access to software for equipment revisions and software patches. The CC needs physiological monitoring hardware and software maintenance for these equipment and interfaces.
Philips is the original equipment manufacturer and sole proprietor of the Philips Physiological Monitoring System. Only this company can provide certified parts and necessary hardware and software upgrades that meets OEM specifications.
Place of Performance or Delivery: The contract period of performance is 09/14/2025 to 09/13/2026 Place of Performance: NIH Clinical Center in Bethesda, MD The statutory authority for this sole source requirement is 41 U.S.C. 1901 (a) (1) as implemented by FAR 13.106-1 only one responsible source and no other supply of service will satisfy agency requirements. THIS IS NOT A REQUEST FOR PROPOSAL. All responsible sources that could provide the required may submit a capability statement that will be considered by email (subject line to reference NOI-CC-25-005233) by 11:00 am eastern standard time on 09/12/2025 to:
lu-chang.lu@nih.gov All responses received by the closing date of this synopsis will be considered by the Government. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Philips North America LLC
- UEI
- L39CAPDUSB98
- CAGE
- 2D600
- Vendor location
- Cambridge, MA
- Contract
- 75N90025P00722, purchase order
- Obligated
- $176,864.57
- Actions
- 1 between September 15, 2025 and September 15, 2025
- Competition
- Not Competed Under SAP, 1 offer received
- Set-aside reported
- No Set Aside Used.
- Described as
- Philips Healthcare Physiological Monitoring Hardware and Software Maintenance from Philips Medical Systems North America INC:1106334 [25-005233]
- Match
- solicitation number NOICC25005233 equals the FPDS solicitation identifier; same awarding office 75N900 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
September 9, 2025
Presolicitation
Due September 12, 2025 at 11:00 AM EDT. SAM.gov, notice 1eacfe363b1747d0b8a60c4c405fff33
Points of contact
- Lu Changlu-chang.lu@nih.gov
Also open from this buyer
- ASIT.TO 1 year software support from ArgonSoft (Notice of Intent to sole source)PresolicitationNAICS 513210Bethesda, MDNOI-CC-26-000808Closes in 49 daysNov 5